Regenerative AC/DC operation combines sourcing and sinking with AC, DC or AC+DC output.
ZGX – Bidirectional AC/DC Source and Load up to 22.5 kVA
For grid simulation, PHIL and inverter testing with four-quadrant operation and regenerative load functionality.
The ZGX series combines a bidirectional AC/DC source, regenerative electronic load and grid simulation in a compact 4U system. AC, DC and AC+DC output, programmable waveforms and four-quadrant operation cover demanding test tasks. For PHIL and HIL applications, the optional EXDA box adds isolated analogue inputs and outputs.
Sequences, harmonics, inter-harmonics and RLC/RCD models reproduce defined supply and load conditions.
Four power levels in 4U and master-slave parallel operation support systems from one instrument to scaled test installations.
The extension box adds eight analogue inputs and four analogue outputs with 500 kHz sampling for PHIL-oriented control loops.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
ZGX 5 Master Bidirectional AC/DC source and load, 5 kVA / 5 kW, AC 0–450 V L-N, DC 0–636 V, 0–30 A, 4U
|
Current [A]
30
|
Power [P]
5000
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX 15 Master Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
|
Current [A]
90
|
Power [P]
15000
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX 15 Slave Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
|
Current [A]
90
|
Power [P]
15000
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX 20 Master Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
|
Current [A]
105
|
Power [P]
20000
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX 20 Slave Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
|
Current [A]
105
|
Power [P]
20000
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX 22.5 Master Bidirectional AC/DC source and load, 22.5 kVA / 22.5 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
|
Current [A]
105
|
Power [P]
22500
|
Voltage [V]
450
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
ZGX-X Customized Customized bidirectional AC/DC source and load, project-specific configuration
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
|
Description
EXDA Accessory for ZGX series, analog programming interface for PHIL applications
|
Technical Data
Product category
AC Bidirectional
AC Electronic Load
AC Power Supply
Type of AC Load
Regenerative Load
Type of AC source
Current-controlled CC
Source + Load
Grid simulator
Single-/Three-phase
ZGX bidirectional AC/DC source and load overview
The ZGX series is a compact, modular four-quadrant source and load for AC and DC testing. Its SiC-based power stage operates as a bidirectional AC/DC source, regenerative electronic load, grid simulator, bipolar DC source and RLC/RCD load. Depending on the model, 5, 15, 20 or 22.5 kVA in AC operation or kW in DC operation is available in a 4U enclosure.
The three phases can be controlled independently or combined for single-phase applications. In addition to AC, DC and AC+DC output, the series supports voltage and frequency sequences, harmonics and inter-harmonics, user-defined waveforms, phase jumps and ride-through scenarios. LAN with SCPI/Modbus, an integrated graphical user interface, remote sense, TTL trigger and an external emergency-stop interface support automated test systems. The optional EXDA Analog & Digital IO Extension Box adds fast analogue channels isolated from the ZGX output for PHIL and HIL-oriented applications.
Key benefits
Bidirectional four-quadrant operation
An AC/DC source and regenerative load are combined in one instrument. Electrical energy can be sourced or absorbed.
Wide frequency range
The AC output covers 0.01 to 1,000 Hz for grid, frequency-converter and avionics-bus simulation.
Programmable waveforms
Harmonics up to the 100th order, inter-harmonics and user-defined curves reproduce supply and disturbance scenarios.
Complex load models
Twelve RLC and four RCD topologies simulate linear and nonlinear loads with separately programmable phase parameters.
Fast control response
A 10 kHz small-signal bandwidth and specified voltage and current slew rates support dynamic test profiles.
Optional analogue extension
EXDA provides isolated analogue inputs and outputs with 500 kHz sampling for fast external control and feedback.
Operating principle and power flow
The ZGX controls voltage or current in both directions of power flow. In source operation it generates programmable AC, DC or AC+DC signals; in load operation it absorbs electrical energy regeneratively. AC and DC load functions, phase control and programmable limits are therefore combined in the same platform.
Each of the three output phases is individually adjustable. Outputs can operate as three-phase, single-phase, split-phase, multi-channel or reverse-phase configurations. For higher voltage, High Voltage Mode uses two outputs with a 180-degree phase shift. Positive and negative output polarities are available in bipolar DC operation.
Power range and models
| Model | AC / DC rated power | Single-phase AC | Three-phase AC | DC per channel | DC, three channels in parallel |
|---|---|---|---|---|---|
| ZGX 5 | 5 kVA / 5 kW | 0-30 A | Not provided | -30 to +30 A | -90 to +90 A |
| ZGX 15 | 15 kVA / 15 kW | 0-90 A | 0-30 A/phase | -30 to +30 A | -90 to +90 A |
| ZGX 20 | 20 kVA / 20 kW | 0-105 A | 0-35 A/phase | -35 to +35 A | -105 to +105 A |
| ZGX 22.5 | 22.5 kVA / 22.5 kW | 0-105 A | 0-35 A/phase | -35 to +35 A | -105 to +105 A |
Common voltage ranges: AC operation provides 0-450 V L-N at 0.01-70 Hz and 0-300 V L-N above 70 Hz to 1 kHz. The DC range is 0-636 V. In AC+DC operation, the power, voltage and current ranges are the same as in DC mode.
| Operating mode | Voltage range | Model condition |
|---|---|---|
| High Voltage AC, single-phase | 0-900 V L-N at 0.01-70 Hz; 0-600 V L-N above 70 Hz to 1 kHz | ZGX 15, ZGX 20 and ZGX 22.5 |
| High Voltage DC | 0-1,272 V | ZGX 15, ZGX 20 and ZGX 22.5 |
| Bipolar DC output | +636 V and -636 V; up to ±30 A or ±35 A | ZGX 15 or ZGX 20 and ZGX 22.5 respectively |
The simultaneous voltage and current combination remains limited by the rated power of the selected model. For the ZGX 15, ZGX 20 and ZGX 22.5, a single-phase mains input reduces rated three-phase output power to 5.0 kW, 6.6 kW and 7.5 kW respectively.
Dynamics, signal quality and measurement
The ZGX provides a voltage slew rate up to 3 V/µs and a current slew rate up to 0.4 A/µs. Small-signal bandwidth is 10 kHz. In no-load DC voltage operation, rise and fall times between 0 and 636 V are below 200 µs; in current operation, transitions from 0 to 90% of full scale and back are completed within 120 µs.
AC voltage accuracy is specified as 0.1% FS and power accuracy as 0.2% FS. AC current accuracy depends on frequency. In DC operation, voltage and current accuracy are both specified as 0.1% FS. The graphical interface displays output voltages and currents, active and reactive power, frequencies, remote-sense readings, temperatures and harmonic analysis.
Operating modes and programmable functions
| Function | Operation | Benefit in the test system |
|---|---|---|
| Grid simulation | Programmable voltage, frequency, phase, ramps, phase jumps and high-, low- and zero-voltage ride-through | Repeatable testing of grid anomalies and grid-support functions |
| Harmonics and inter-harmonics | Up to the 100th order at 50/60 Hz and the 25th order at 400 Hz; programmable amplitude and phase | Targeted generation of periodically distorted voltage and current |
| User-defined waveforms | Import and editing with 1,024, 2,048 or 4,096 points plus stored standard waveforms | Reusable application-specific signal profiles |
| Regenerative AC load | CR, CC, CP and rectifier operation; current phase angle from -90 to +90 degrees | Simulation of resistive, inductive, capacitive and nonlinear loads |
| Regenerative DC load | CC and CP operation with sequences, adjustable impedance and minimum operating voltage | Dynamic DC loading with defined operating steps |
| RLC/RCD load | Twelve RLC and four RCD topologies; parameters set separately for each phase | Reproduction of complex impedances and nonlinear rectifier loads |
| List and Sequence modes | Multi-step routines with setpoints, ramps, duration, loops and output state | Automated, repeatable profiles without manual setpoint changes |
Typical applications
PV inverters and grid simulation
The ZGX generates programmable grid conditions and loads the DUT regeneratively. Frequency variation, phase jumps, ride-through and harmonics support grid-integration tests.
On-board chargers and charging electronics
Four-quadrant operation, grid-fault profiles and leakage current below 10 mA at 230 V L-N support testing of sensitive charging equipment.
Motor drives and frequency converters
RLC/RCD models, individual phase control and regenerative load modes reproduce linear and nonlinear power-electronics loads.
UPS systems and power supplies
Rectifier loading, sequences and user-defined waveforms test response and stability under changing or distorted load conditions.
Avionics bus simulation
The frequency range up to 1 kHz reproduces normal operation, interruption, transfer, abnormal supply and start-up conditions in aircraft electrical buses.
Power Hardware-in-the-Loop
The optional EXDA box couples external real-time signals to the ZGX and provides isolated analogue outputs for fast feedback.
Interfaces, software and automation
| Equipment | Availability | Function |
|---|---|---|
| LAN | Standard | Remote control and test-system integration via SCPI and Modbus |
| 7-inch touchscreen with GUI | Integrated | Configuration, setpoints, measurement data, waveform display and stored test routines |
| Front USB | Integrated | File transfer for waveforms and parameter sets |
| TTL trigger output | Integrated | Signals voltage or frequency changes to external measurement equipment |
| Remote sense | Integrated | Compensates lead voltage drop at the DUT |
| External emergency stop | Integrated interface | Connection of an external switch to the instrument concept |
| Master-slave COM1 | Integrated | Communication between identical ZGX instruments in parallel operation |
| EXDA | Optional | Analogue programming and feedback plus reserved digital and communication channels for project-specific use |
Optional EXDA Analog & Digital IO Extension Box
EXDA is a separate extension box for the ZGX series. It requires an independent single-phase 220 V AC supply and connects to the ZGX by fibre optics. Its primary purpose is fast analogue setpoint control and measurement feedback for PHIL and HIL-oriented applications.
| EXDA interface | Technical implementation | Function and status |
|---|---|---|
| 8 analogue inputs | SMA, ±10 V peak, 500 kHz, isolated from the ZGX output | External voltage or current waveform for PHIL amplification mode; signal-to-output delay up to 20 µs |
| 4 analogue outputs | SMA, ±10 V, 500 kHz, isolated from the ZGX output | Feedback of four phase-voltage or phase-current values to be defined when configuring the system |
| 4 digital inputs / 4 digital outputs | 0-5 V | Reserved; project-specific control, readback and logic functions require clarification |
| 2 COM interfaces | COM1 and COM2 | COM1 communicates with the ZGX; COM2 is reserved |
| 3 LAN interfaces | RJ45 | Reserved and not specified as ready-to-use standard communication functions |
Configuration note: EXDA analogue channels are not standard ZGX equipment. Required feedback variables and project-specific digital functions must be defined during system configuration. SMA connectors must not be connected or disconnected while powered.
Parallel operation and scaling
For higher power, up to ten ZGX instruments of the same model can operate in a master-slave configuration. One instrument acts as the master and the remaining units follow as slaves through the designated communication link. Output configuration, cabling, protection concept and AC infrastructure must be sized for total system power.
The -S ordering option identifies a slave unit and is listed for the ZGX 15 and ZGX 20. Factory-configured high-power systems are available for requirements beyond standard-unit scaling; their architecture is engineered for the individual project.
Installation and infrastructure
| Characteristic | Requirement or implementation |
|---|---|
| Form factor | 440 x 670 x 178 mm, 4U |
| Weight | ZGX 5 below 40 kg; ZGX 15 approximately 47 kg; ZGX 20 and ZGX 22.5 approximately 50 kg |
| AC input | 47-63 Hz; configurations for 380 or 400 V L-L, 3P+PE |
| Additional input configurations | 208 or 230 V L-L, 3P+PE only for ZGX 5 and ZGX 15; observe power derating with 220/230 V L-N single-phase input |
| Cooling | Forced-air cooling; keep inlet and exhaust paths clear |
| Temperature | Operation 0-40 °C; storage -20 to +85 °C |
| Humidity | 20-90% relative humidity, non-condensing |
| Ingress protection | IP21 |
Protection and monitoring functions
The ZGX monitors overvoltage, overcurrent, overpower and overtemperature through OVP, OCP, OPP and OTP. The manuals additionally describe adjustable input undervoltage monitoring, current limiting and ramp parameters. When configured thresholds are exceeded, the output is disabled or the current is limited accordingly.
Remote sense, the external emergency-stop interface and status indications support test-system integration. These instrument functions do not replace the risk assessment, interlocks and protective equipment of the complete test system.
ZGX FAQ
How is the appropriate ZGX model selected?
Required voltage, current, power, phase count and frequency must be considered together. Input configuration, parallel operation, dynamics and interfaces must also be defined.
Can the ZGX provide maximum voltage and maximum current simultaneously?
Only if the operating point remains within the model's rated power. Voltage, current and power must therefore be checked as a combined load characteristic.
Which output formats are available?
The series supports AC, DC and AC+DC plus single-phase, three-phase and multi-channel configurations. High Voltage and bipolar DC operation depend on the model.
What does the optional EXDA add?
EXDA provides eight isolated analogue inputs and four isolated analogue outputs at 500 kHz. It is intended for external control, PHIL signal amplification and fast feedback.
Are all EXDA connectors immediately usable?
No. The digital I/Os and three LAN ports are reserved, as is COM2. Required project-specific functions must be clarified before configuration.
How can output power be expanded?
Up to ten instruments of the same model can operate as a master-slave system. Electrical infrastructure and system protection must be designed for total power.
Can the ZGX be used for on-board charger testing?
Yes. Programmable grid conditions, four-quadrant operation and the specified low leakage current support AC-side testing of OBCs and charging electronics.
Is the ZGX suitable for PV inverter and grid-connection testing?
Yes. Voltage and frequency sequences, ride-through, phase jumps, harmonics and regenerative load functions reproduce the documented grid tests.
Can the ZGX reproduce complex UPS or converter loads?
Yes. Twelve RLC and four RCD topologies, rectifier operation and per-phase parameters support linear and nonlinear load simulation.
Which option is intended for PHIL applications?
The EXDA box adds fast analogue setpoint and feedback channels. The ZGX itself provides 10 kHz small-signal bandwidth; the specific loop design is project-dependent.
Technical consultation and project enquiry
To select a ZGX configuration, provide AC and DC voltage ranges, currents, power, phase and frequency requirements, plus the intended source, load and grid-simulation functions. For EXDA projects, also specify the real-time system, signal levels, required analogue channels, feedback variables and digital functions.
- Download Datasheet - Bidirectional AC Source and Load ZGX
- Download EXDA Analog and Digital IO Extension Box
- Download Manual - Bidirectional AC Source and Load ZGX 15
- Download Manual - Bidirectional AC Source and Load ZGX 20
- Download Manual - Bidirectional AC Source and Load ZGX 22.5
- Download ZGX User Manual - Remote Software (EN) V1.2
HIL Interface Box
EXDA analogue and digital I/O extension box overview
The EXDA is an external interface extension for bidirectional ZGX Series AC/DC sources. It adds eight analogue inputs, four analogue outputs, four digital inputs, four digital outputs, three LAN ports and two serial COM interfaces to the ZGX system. The analogue SMA interfaces operate at a sampling rate of 500 kHz and are isolated from the ZGX output. On the input side, the box supports analogue setpoint control for PHIL applications; on the output side, four selected phase-voltage or phase-current values can be returned as analogue signals. Communication with the ZGX uses fibre optics, while the EXDA is supplied separately from a single-phase 220 V AC source. Digital I/O, LAN and COM2 are intended for reserved or application-specific configured functions.
Key benefits
Fast analogue paths
Analogue inputs and outputs sample or transfer signals at 500 kHz for time-critical control and measurement tasks.
Short PHIL delay
In PHIL amplification mode, the delay from the analogue signal input to the ZGX output is 20 µs.
Separate control and readback
Eight analogue inputs support control tasks, while four analogue outputs return selected ZGX voltage or current values.
Isolated analogue connectors
An isolated shell and signal ground plus isolation from the ZGX output support a clearly defined signal connection.
Locking coaxial connection
SMA sockets with a locking mechanism and strain relief provide a mechanically secured connection for analogue signals.
Project-specific extension
Digital I/O can be customised for control, readback and logic tasks; additional COM and LAN ports are reserved.
Operating principle and system connection
The EXDA provides the external signal layer between higher-level measurement, simulation or control equipment and a ZGX source. Analogue setpoint signals are applied through SMA sockets and converted into ZGX output voltage or output current in PHIL amplification mode. CV or CC mode is selected in the software to determine voltage or current control.
For readback, the EXDA provides four analogue outputs. For each order, four required monitoring quantities are selected from phase A, B and C voltages and currents. These signals can be routed to oscilloscopes, data-acquisition systems or other measuring devices.
Important connection note: Hot plugging at the SMA connectors is prohibited. Power must be switched off before connecting or disconnecting SMA plugs to prevent damage to the device under test.
Analogue inputs for PHIL control
| Feature | Implementation | Technical meaning |
|---|---|---|
| Quantity and connector | 8 analogue inputs, SMA female | External analogue signals are applied through coaxial cables. |
| Signal range | ±10 V peak | Defined input range for analogue setpoint control. |
| Sampling rate | 500 kHz | Fast processing of external control signals. |
| Delay | 20 µs | From signal input to ZGX output in PHIL amplification mode. |
| Voltage scaling | 66.5 V/V | 1 V external input signal corresponds to 66.5 V ZGX output voltage. |
| Current scaling | 10 A/V | 1 V external input signal corresponds to 10 A ZGX output current. |
| Isolation | Isolated shell and signal ground; isolated from the ZGX output | Separates the external analogue signal layer from the power output. |
| Operating assignment | CV for voltage, CC for current | The software selection determines which ZGX output quantity is controlled by the analogue signal. |
Analogue readback and measurement connection
| Feature | Implementation | Technical meaning |
|---|---|---|
| Quantity and connector | 4 analogue outputs, SMA female | Four selected measurements can be output in parallel. |
| Selectable quantities | Phase A, B and C voltage or current | The four required monitoring parameters must be specified when ordering. |
| Signal range | ±10 V | Analogue output range for connecting external measurement equipment. |
| Sampling rate | 500 kHz | Fast readback of the selected ZGX measurements. |
| Voltage scaling | 0.0149 V/V | 1 V ZGX output voltage corresponds to 0.0149 V at the analogue output. |
| Current scaling | 0.1 V/A | 1 A ZGX output current corresponds to 0.1 V at the analogue output. |
| Isolation | Isolated shell and signal ground; isolated from the ZGX output | Supports separate signal transfer to an oscilloscope or data-acquisition system. |
Digital and communication interfaces
| Interface | Status | Function |
|---|---|---|
| 4 digital inputs | Reserved, 0 to 5 V | Customisable for application-specific control, readback and logic functions. |
| 4 digital outputs | Reserved, 0 to 5 V | Customisable for application-specific control, readback and logic functions. |
| COM1 | Assigned | Serial communication with the ZGX. |
| COM2 | Reserved | No fixed function is specified. |
| 3 LAN ports | Reserved | No fixed function is specified. |
Installation and connection
| Item | Requirement | Note |
|---|---|---|
| Supply | Separate single-phase 220 V AC supply | The EXDA is powered independently of the ZGX. |
| Connection to ZGX | Fibre optics | System communication between the EXDA and ZGX uses an optical link. |
| Analogue cabling | Coaxial cable, standard length 1 m | SMA connectors with a locking mechanism and strain relief. |
| Connecting or disconnecting | Only with power switched off | Do not connect or disconnect SMA plugs during operation. |
Typical applications
Power Hardware-in-the-Loop
The EXDA transfers external analogue setpoint signals to the ZGX, supporting its operation as a power amplifier in PHIL setups.
Real-time RMS control
Analogue control and measurement paths enable real-time RMS setpoint control and readback within a coordinated ZGX configuration.
External data acquisition
Selected ZGX phase voltages and currents can be output as analogue signals to oscilloscopes, data-acquisition systems or other measurement devices.
Frequently asked questions about the EXDA
Which equipment is the EXDA designed for?
The extension box is designed for bidirectional ZGX Series AC/DC sources and connects to the ZGX via fibre optics.
What power supply does the EXDA require?
It requires a separate single-phase 220 V AC supply.
How many analogue channels are available?
The EXDA provides eight analogue inputs and four analogue outputs with SMA connectors.
Which values can the analogue outputs return?
Four values can be selected from phase A, B and C voltages and currents. The required assignment must be specified when ordering.
Are the LAN ports and digital I/O immediately available for general use?
The three LAN ports and the digital inputs and outputs are identified as reserved interfaces. Digital functions are configured for the application.
Can the EXDA be used for PHIL applications?
Yes. The analogue inputs support PHIL signal amplification mode, with a 20 µs delay from signal input to ZGX output.
Can ZGX signals be captured with an oscilloscope?
Yes. The analogue outputs can transfer selected phase voltages or currents to an oscilloscope or data-acquisition system.
May SMA connectors be changed during operation?
No. Power must be switched off before connecting or disconnecting the SMA connectors.
Technical consultation and project enquiry
Planning an EXDA configuration requires the ZGX version in use, the required analogue control quantities, the four required readback values and any requirements for digital control, readback or logic functions.
Contact ET System to coordinate your EXDA and ZGX configuration.