Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
ZGX 5 Master

Description
ZGX 5 Master Bidirectional AC/DC source and load, 5 kVA / 5 kW, AC 0–450 V L-N, DC 0–636 V, 0–30 A, 4U
Current [A]
30
Power [P]
5000
Voltage [V]
450
ZGX 5 Master
ZGX 5 Master Bidirectional AC/DC source and load, 5 kVA / 5 kW, AC 0–450 V L-N, DC 0–636 V, 0–30 A, 4U
30
5000
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX 15 Master

Description
ZGX 15 Master Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
Current [A]
90
Power [P]
15000
Voltage [V]
450
ZGX 15 Master
ZGX 15 Master Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
90
15000
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX 15 Slave

Description
ZGX 15 Slave Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
Current [A]
90
Power [P]
15000
Voltage [V]
450
ZGX 15 Slave
ZGX 15 Slave Bidirectional AC/DC source and load, 15 kVA / 15 kW, AC 0–450 V L-N, DC 0–636 V, 0–90 A, 4U
90
15000
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX 20 Master

Description
ZGX 20 Master Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
Current [A]
105
Power [P]
20000
Voltage [V]
450
ZGX 20 Master
ZGX 20 Master Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
105
20000
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX 20 Slave

Description
ZGX 20 Slave Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
Current [A]
105
Power [P]
20000
Voltage [V]
450
ZGX 20 Slave
ZGX 20 Slave Bidirectional AC/DC source and load, 20 kVA / 20 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
105
20000
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX 22.5 Master

Description
ZGX 22.5 Master Bidirectional AC/DC source and load, 22.5 kVA / 22.5 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
Current [A]
105
Power [P]
22500
Voltage [V]
450
ZGX 22.5 Master
ZGX 22.5 Master Bidirectional AC/DC source and load, 22.5 kVA / 22.5 kW, AC 0–450 V L-N, DC 0–636 V, 0–105 A, 4U
105
22500
450
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX-X

Description
ZGX-X Customized Customized bidirectional AC/DC source and load, project-specific configuration
ZGX-X
ZGX-X Customized Customized bidirectional AC/DC source and load, project-specific configuration
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

EXDA

Description
EXDA Accessory for ZGX series, analog programming interface for PHIL applications
EXDA
EXDA Accessory for ZGX series, analog programming interface for PHIL applications
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Current-controlled CC

Source + Load

Grid simulator

Single-/Three-phase

ZGX bidirectional AC/DC source and load overview

The ZGX series is a compact, modular four-quadrant source and load for AC and DC testing. Its SiC-based power stage operates as a bidirectional AC/DC source, regenerative electronic load, grid simulator, bipolar DC source and RLC/RCD load. Depending on the model, 5, 15, 20 or 22.5 kVA in AC operation or kW in DC operation is available in a 4U enclosure.

The three phases can be controlled independently or combined for single-phase applications. In addition to AC, DC and AC+DC output, the series supports voltage and frequency sequences, harmonics and inter-harmonics, user-defined waveforms, phase jumps and ride-through scenarios. LAN with SCPI/Modbus, an integrated graphical user interface, remote sense, TTL trigger and an external emergency-stop interface support automated test systems. The optional EXDA Analog & Digital IO Extension Box adds fast analogue channels isolated from the ZGX output for PHIL and HIL-oriented applications.

Key benefits

Bidirectional four-quadrant operation

An AC/DC source and regenerative load are combined in one instrument. Electrical energy can be sourced or absorbed.

Wide frequency range

The AC output covers 0.01 to 1,000 Hz for grid, frequency-converter and avionics-bus simulation.

Programmable waveforms

Harmonics up to the 100th order, inter-harmonics and user-defined curves reproduce supply and disturbance scenarios.

Complex load models

Twelve RLC and four RCD topologies simulate linear and nonlinear loads with separately programmable phase parameters.

Fast control response

A 10 kHz small-signal bandwidth and specified voltage and current slew rates support dynamic test profiles.

Optional analogue extension

EXDA provides isolated analogue inputs and outputs with 500 kHz sampling for fast external control and feedback.

Operating principle and power flow

The ZGX controls voltage or current in both directions of power flow. In source operation it generates programmable AC, DC or AC+DC signals; in load operation it absorbs electrical energy regeneratively. AC and DC load functions, phase control and programmable limits are therefore combined in the same platform.

Each of the three output phases is individually adjustable. Outputs can operate as three-phase, single-phase, split-phase, multi-channel or reverse-phase configurations. For higher voltage, High Voltage Mode uses two outputs with a 180-degree phase shift. Positive and negative output polarities are available in bipolar DC operation.

Power range and models

ModelAC / DC rated powerSingle-phase ACThree-phase ACDC per channelDC, three channels in parallel
ZGX 55 kVA / 5 kW0-30 ANot provided-30 to +30 A-90 to +90 A
ZGX 1515 kVA / 15 kW0-90 A0-30 A/phase-30 to +30 A-90 to +90 A
ZGX 2020 kVA / 20 kW0-105 A0-35 A/phase-35 to +35 A-105 to +105 A
ZGX 22.522.5 kVA / 22.5 kW0-105 A0-35 A/phase-35 to +35 A-105 to +105 A

Common voltage ranges: AC operation provides 0-450 V L-N at 0.01-70 Hz and 0-300 V L-N above 70 Hz to 1 kHz. The DC range is 0-636 V. In AC+DC operation, the power, voltage and current ranges are the same as in DC mode.

Operating modeVoltage rangeModel condition
High Voltage AC, single-phase0-900 V L-N at 0.01-70 Hz; 0-600 V L-N above 70 Hz to 1 kHzZGX 15, ZGX 20 and ZGX 22.5
High Voltage DC0-1,272 VZGX 15, ZGX 20 and ZGX 22.5
Bipolar DC output+636 V and -636 V; up to ±30 A or ±35 AZGX 15 or ZGX 20 and ZGX 22.5 respectively

The simultaneous voltage and current combination remains limited by the rated power of the selected model. For the ZGX 15, ZGX 20 and ZGX 22.5, a single-phase mains input reduces rated three-phase output power to 5.0 kW, 6.6 kW and 7.5 kW respectively.

Dynamics, signal quality and measurement

The ZGX provides a voltage slew rate up to 3 V/µs and a current slew rate up to 0.4 A/µs. Small-signal bandwidth is 10 kHz. In no-load DC voltage operation, rise and fall times between 0 and 636 V are below 200 µs; in current operation, transitions from 0 to 90% of full scale and back are completed within 120 µs.

AC voltage accuracy is specified as 0.1% FS and power accuracy as 0.2% FS. AC current accuracy depends on frequency. In DC operation, voltage and current accuracy are both specified as 0.1% FS. The graphical interface displays output voltages and currents, active and reactive power, frequencies, remote-sense readings, temperatures and harmonic analysis.

Operating modes and programmable functions

FunctionOperationBenefit in the test system
Grid simulationProgrammable voltage, frequency, phase, ramps, phase jumps and high-, low- and zero-voltage ride-throughRepeatable testing of grid anomalies and grid-support functions
Harmonics and inter-harmonicsUp to the 100th order at 50/60 Hz and the 25th order at 400 Hz; programmable amplitude and phaseTargeted generation of periodically distorted voltage and current
User-defined waveformsImport and editing with 1,024, 2,048 or 4,096 points plus stored standard waveformsReusable application-specific signal profiles
Regenerative AC loadCR, CC, CP and rectifier operation; current phase angle from -90 to +90 degreesSimulation of resistive, inductive, capacitive and nonlinear loads
Regenerative DC loadCC and CP operation with sequences, adjustable impedance and minimum operating voltageDynamic DC loading with defined operating steps
RLC/RCD loadTwelve RLC and four RCD topologies; parameters set separately for each phaseReproduction of complex impedances and nonlinear rectifier loads
List and Sequence modesMulti-step routines with setpoints, ramps, duration, loops and output stateAutomated, repeatable profiles without manual setpoint changes

Typical applications

PV inverters and grid simulation

The ZGX generates programmable grid conditions and loads the DUT regeneratively. Frequency variation, phase jumps, ride-through and harmonics support grid-integration tests.

Motor drives and frequency converters

RLC/RCD models, individual phase control and regenerative load modes reproduce linear and nonlinear power-electronics loads.

UPS systems and power supplies

Rectifier loading, sequences and user-defined waveforms test response and stability under changing or distorted load conditions.

Avionics bus simulation

The frequency range up to 1 kHz reproduces normal operation, interruption, transfer, abnormal supply and start-up conditions in aircraft electrical buses.

Power Hardware-in-the-Loop

The optional EXDA box couples external real-time signals to the ZGX and provides isolated analogue outputs for fast feedback.

Interfaces, software and automation

EquipmentAvailabilityFunction
LANStandardRemote control and test-system integration via SCPI and Modbus
7-inch touchscreen with GUIIntegratedConfiguration, setpoints, measurement data, waveform display and stored test routines
Front USBIntegratedFile transfer for waveforms and parameter sets
TTL trigger outputIntegratedSignals voltage or frequency changes to external measurement equipment
Remote senseIntegratedCompensates lead voltage drop at the DUT
External emergency stopIntegrated interfaceConnection of an external switch to the instrument concept
Master-slave COM1IntegratedCommunication between identical ZGX instruments in parallel operation
EXDAOptionalAnalogue programming and feedback plus reserved digital and communication channels for project-specific use

Optional EXDA Analog & Digital IO Extension Box

EXDA is a separate extension box for the ZGX series. It requires an independent single-phase 220 V AC supply and connects to the ZGX by fibre optics. Its primary purpose is fast analogue setpoint control and measurement feedback for PHIL and HIL-oriented applications.

EXDA interfaceTechnical implementationFunction and status
8 analogue inputsSMA, ±10 V peak, 500 kHz, isolated from the ZGX outputExternal voltage or current waveform for PHIL amplification mode; signal-to-output delay up to 20 µs
4 analogue outputsSMA, ±10 V, 500 kHz, isolated from the ZGX outputFeedback of four phase-voltage or phase-current values to be defined when configuring the system
4 digital inputs / 4 digital outputs0-5 VReserved; project-specific control, readback and logic functions require clarification
2 COM interfacesCOM1 and COM2COM1 communicates with the ZGX; COM2 is reserved
3 LAN interfacesRJ45Reserved and not specified as ready-to-use standard communication functions

Configuration note: EXDA analogue channels are not standard ZGX equipment. Required feedback variables and project-specific digital functions must be defined during system configuration. SMA connectors must not be connected or disconnected while powered.

Parallel operation and scaling

For higher power, up to ten ZGX instruments of the same model can operate in a master-slave configuration. One instrument acts as the master and the remaining units follow as slaves through the designated communication link. Output configuration, cabling, protection concept and AC infrastructure must be sized for total system power.

The -S ordering option identifies a slave unit and is listed for the ZGX 15 and ZGX 20. Factory-configured high-power systems are available for requirements beyond standard-unit scaling; their architecture is engineered for the individual project.

Installation and infrastructure

CharacteristicRequirement or implementation
Form factor440 x 670 x 178 mm, 4U
WeightZGX 5 below 40 kg; ZGX 15 approximately 47 kg; ZGX 20 and ZGX 22.5 approximately 50 kg
AC input47-63 Hz; configurations for 380 or 400 V L-L, 3P+PE
Additional input configurations208 or 230 V L-L, 3P+PE only for ZGX 5 and ZGX 15; observe power derating with 220/230 V L-N single-phase input
CoolingForced-air cooling; keep inlet and exhaust paths clear
TemperatureOperation 0-40 °C; storage -20 to +85 °C
Humidity20-90% relative humidity, non-condensing
Ingress protectionIP21

Protection and monitoring functions

The ZGX monitors overvoltage, overcurrent, overpower and overtemperature through OVP, OCP, OPP and OTP. The manuals additionally describe adjustable input undervoltage monitoring, current limiting and ramp parameters. When configured thresholds are exceeded, the output is disabled or the current is limited accordingly.

Remote sense, the external emergency-stop interface and status indications support test-system integration. These instrument functions do not replace the risk assessment, interlocks and protective equipment of the complete test system.

ZGX FAQ

How is the appropriate ZGX model selected?

Required voltage, current, power, phase count and frequency must be considered together. Input configuration, parallel operation, dynamics and interfaces must also be defined.

Can the ZGX provide maximum voltage and maximum current simultaneously?

Only if the operating point remains within the model's rated power. Voltage, current and power must therefore be checked as a combined load characteristic.

Which output formats are available?

The series supports AC, DC and AC+DC plus single-phase, three-phase and multi-channel configurations. High Voltage and bipolar DC operation depend on the model.

What does the optional EXDA add?

EXDA provides eight isolated analogue inputs and four isolated analogue outputs at 500 kHz. It is intended for external control, PHIL signal amplification and fast feedback.

Are all EXDA connectors immediately usable?

No. The digital I/Os and three LAN ports are reserved, as is COM2. Required project-specific functions must be clarified before configuration.

How can output power be expanded?

Up to ten instruments of the same model can operate as a master-slave system. Electrical infrastructure and system protection must be designed for total power.

Can the ZGX be used for on-board charger testing?

Yes. Programmable grid conditions, four-quadrant operation and the specified low leakage current support AC-side testing of OBCs and charging electronics.

Is the ZGX suitable for PV inverter and grid-connection testing?

Yes. Voltage and frequency sequences, ride-through, phase jumps, harmonics and regenerative load functions reproduce the documented grid tests.

Can the ZGX reproduce complex UPS or converter loads?

Yes. Twelve RLC and four RCD topologies, rectifier operation and per-phase parameters support linear and nonlinear load simulation.

Which option is intended for PHIL applications?

The EXDA box adds fast analogue setpoint and feedback channels. The ZGX itself provides 10 kHz small-signal bandwidth; the specific loop design is project-dependent.

Technical consultation and project enquiry

To select a ZGX configuration, provide AC and DC voltage ranges, currents, power, phase and frequency requirements, plus the intended source, load and grid-simulation functions. For EXDA projects, also specify the real-time system, signal levels, required analogue channels, feedback variables and digital functions.

Discuss your ZGX and EXDA project with ET System

HIL Interface Box

EXDA analogue and digital I/O extension box overview

The EXDA is an external interface extension for bidirectional ZGX Series AC/DC sources. It adds eight analogue inputs, four analogue outputs, four digital inputs, four digital outputs, three LAN ports and two serial COM interfaces to the ZGX system. The analogue SMA interfaces operate at a sampling rate of 500 kHz and are isolated from the ZGX output. On the input side, the box supports analogue setpoint control for PHIL applications; on the output side, four selected phase-voltage or phase-current values can be returned as analogue signals. Communication with the ZGX uses fibre optics, while the EXDA is supplied separately from a single-phase 220 V AC source. Digital I/O, LAN and COM2 are intended for reserved or application-specific configured functions.

Key benefits

Fast analogue paths

Analogue inputs and outputs sample or transfer signals at 500 kHz for time-critical control and measurement tasks.

Short PHIL delay

In PHIL amplification mode, the delay from the analogue signal input to the ZGX output is 20 µs.

Separate control and readback

Eight analogue inputs support control tasks, while four analogue outputs return selected ZGX voltage or current values.

Isolated analogue connectors

An isolated shell and signal ground plus isolation from the ZGX output support a clearly defined signal connection.

Locking coaxial connection

SMA sockets with a locking mechanism and strain relief provide a mechanically secured connection for analogue signals.

Project-specific extension

Digital I/O can be customised for control, readback and logic tasks; additional COM and LAN ports are reserved.

Operating principle and system connection

The EXDA provides the external signal layer between higher-level measurement, simulation or control equipment and a ZGX source. Analogue setpoint signals are applied through SMA sockets and converted into ZGX output voltage or output current in PHIL amplification mode. CV or CC mode is selected in the software to determine voltage or current control.

For readback, the EXDA provides four analogue outputs. For each order, four required monitoring quantities are selected from phase A, B and C voltages and currents. These signals can be routed to oscilloscopes, data-acquisition systems or other measuring devices.

Important connection note: Hot plugging at the SMA connectors is prohibited. Power must be switched off before connecting or disconnecting SMA plugs to prevent damage to the device under test.

Analogue inputs for PHIL control

Feature Implementation Technical meaning
Quantity and connector 8 analogue inputs, SMA female External analogue signals are applied through coaxial cables.
Signal range ±10 V peak Defined input range for analogue setpoint control.
Sampling rate 500 kHz Fast processing of external control signals.
Delay 20 µs From signal input to ZGX output in PHIL amplification mode.
Voltage scaling 66.5 V/V 1 V external input signal corresponds to 66.5 V ZGX output voltage.
Current scaling 10 A/V 1 V external input signal corresponds to 10 A ZGX output current.
Isolation Isolated shell and signal ground; isolated from the ZGX output Separates the external analogue signal layer from the power output.
Operating assignment CV for voltage, CC for current The software selection determines which ZGX output quantity is controlled by the analogue signal.

Analogue readback and measurement connection

Feature Implementation Technical meaning
Quantity and connector 4 analogue outputs, SMA female Four selected measurements can be output in parallel.
Selectable quantities Phase A, B and C voltage or current The four required monitoring parameters must be specified when ordering.
Signal range ±10 V Analogue output range for connecting external measurement equipment.
Sampling rate 500 kHz Fast readback of the selected ZGX measurements.
Voltage scaling 0.0149 V/V 1 V ZGX output voltage corresponds to 0.0149 V at the analogue output.
Current scaling 0.1 V/A 1 A ZGX output current corresponds to 0.1 V at the analogue output.
Isolation Isolated shell and signal ground; isolated from the ZGX output Supports separate signal transfer to an oscilloscope or data-acquisition system.

Digital and communication interfaces

Interface Status Function
4 digital inputs Reserved, 0 to 5 V Customisable for application-specific control, readback and logic functions.
4 digital outputs Reserved, 0 to 5 V Customisable for application-specific control, readback and logic functions.
COM1 Assigned Serial communication with the ZGX.
COM2 Reserved No fixed function is specified.
3 LAN ports Reserved No fixed function is specified.

Installation and connection

Item Requirement Note
Supply Separate single-phase 220 V AC supply The EXDA is powered independently of the ZGX.
Connection to ZGX Fibre optics System communication between the EXDA and ZGX uses an optical link.
Analogue cabling Coaxial cable, standard length 1 m SMA connectors with a locking mechanism and strain relief.
Connecting or disconnecting Only with power switched off Do not connect or disconnect SMA plugs during operation.

Typical applications

Power Hardware-in-the-Loop

The EXDA transfers external analogue setpoint signals to the ZGX, supporting its operation as a power amplifier in PHIL setups.

Real-time RMS control

Analogue control and measurement paths enable real-time RMS setpoint control and readback within a coordinated ZGX configuration.

External data acquisition

Selected ZGX phase voltages and currents can be output as analogue signals to oscilloscopes, data-acquisition systems or other measurement devices.

Frequently asked questions about the EXDA

Which equipment is the EXDA designed for?

The extension box is designed for bidirectional ZGX Series AC/DC sources and connects to the ZGX via fibre optics.

What power supply does the EXDA require?

It requires a separate single-phase 220 V AC supply.

How many analogue channels are available?

The EXDA provides eight analogue inputs and four analogue outputs with SMA connectors.

Which values can the analogue outputs return?

Four values can be selected from phase A, B and C voltages and currents. The required assignment must be specified when ordering.

Are the LAN ports and digital I/O immediately available for general use?

The three LAN ports and the digital inputs and outputs are identified as reserved interfaces. Digital functions are configured for the application.

Can the EXDA be used for PHIL applications?

Yes. The analogue inputs support PHIL signal amplification mode, with a 20 µs delay from signal input to ZGX output.

Can ZGX signals be captured with an oscilloscope?

Yes. The analogue outputs can transfer selected phase voltages or currents to an oscilloscope or data-acquisition system.

May SMA connectors be changed during operation?

No. Power must be switched off before connecting or disconnecting the SMA connectors.

Technical consultation and project enquiry

Planning an EXDA configuration requires the ZGX version in use, the required analogue control quantities, the four required readback values and any requirements for digital control, readback or logic functions.

Contact ET System to coordinate your EXDA and ZGX configuration.

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly