pvServe 3.3

Description
pvServe Multifunctional PV service tool, 0–1000 V DC, 0–5 A, 3.3 kW, 230 V input
Current [A]
4,7
Power [P]
3300
Voltage [V]
1500
pvServe 3.3
pvServe Multifunctional PV service tool, 0–1000 V DC, 0–5 A, 3.3 kW, 230 V input
4,7
3300
1500
PV service DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

pvServe: PV service power supply overview

pvServe is an adjustable DC power supply for inspecting and maintaining photovoltaic systems. It feeds electrical energy into solar module strings to support investigations that require controlled current injection. These include reverse-current thermography for hotspot detection and electroluminescence imaging for examining cell damage. An appropriate camera is required for each imaging method.

The output voltage is adjustable from 0 to 1,000 V and the current limit from 0 to 5 A. Maximum output power is 3.3 kW, limiting the simultaneously available current at higher voltages. Further applications include testing bypass diodes on a darkened solar array and commissioning inverters before the solar modules are installed. Operation is via a graphic display, and mains power is supplied through a 230 V AC connection.

Key benefits

Adapt the operating point

An output voltage of 0–1,000 V and a current limit of 0–5 A support different inspection tasks within the 3.3 kW limit.

Inspect hotspots without sunlight

Controlled current injection enables reverse-current thermography at night, making inspection independent of the minimum solar irradiance otherwise required.

Reveal cell damage

Together with a suitable infrared camera, the power supply supports electroluminescence imaging to detect microcracks in solar cells.

Check bypass diodes

Testing a darkened solar array enables inspection of the bypass diodes within a module string.

Check electrical work earlier

Inverters can be commissioned and functionally checked before the solar array has been installed.

Use an existing mains connection

A 230 V AC supply enables operation from a conventional socket on a circuit with recommended 16 A overcurrent protection.

How controlled current injection works

For thermographic and electroluminescence investigations, pvServe provides current to the solar module string. A thermal imaging camera detects abnormal temperature distributions, while an infrared camera suitable for electroluminescence reveals cell damage. Bypass diode testing instead uses a darkened solar array with the reversed connection polarity required for that test. Test current and voltage must be matched to the specific module string and inspection task.

Operating range and technical specifications

ModelDC output voltageAdjustable current limitMaximum output power
pvServe0–1,000 V0–5 A3.3 kW

Check voltage, current and power together: 1,000 V and 5 A are not available simultaneously. For U > 0 within the output range: Imax = min(5 A, 3,300 W / U).

At 5 A, the maximum available voltage is 660 V. At 1,000 V, the power limit gives a maximum current of 3.3 A. Below 660 V, current remains limited to a maximum of 5 A.

Typical applications

Reverse-current thermography of PV modules

pvServe supplies current to the module string for thermal hotspot detection. Inspection is possible without the minimum irradiance of 400 W/m² otherwise required, including at night.

Electroluminescence for damage analysis

Current injection, together with an additional infrared camera, enables the investigation of microcracks in solar cells.

Bypass diode testing on module strings

On a darkened solar array, the power supply supports functional testing of the bypass diodes. This uses a connection polarity reversed from that used for normal current injection.

PV inverter commissioning

pvServe provides DC power for commissioning before the solar array is installed. This enables functional checks of the electrical work before rooftop installation is complete.

Thawing snow on solar modules

Reverse current can raise the surface temperature of the module glass by approximately 2–4 °C. On roofs with slopes of at least 30°, this can help snow slide off earlier.

Operation, connections and infrastructure

FeatureConfiguration / requirement
OperationGraphic display
Mains supply230 V AC via a conventional socket
Circuit overcurrent protection16 A recommended
DC connectionPositive and negative via 4 mm banana plugs
Weight18.5 kg

pvServe FAQ

Which output values can be adjusted?

DC voltage is adjustable from 0 to 1,000 V and the current limit from 0 to 5 A. The maximum output power of 3.3 kW also applies.

Are 1,000 V and 5 A available simultaneously?

No. That operating point would require 5 kW. At 1,000 V, the 3.3 kW power limit restricts current to a maximum of 3.3 A.

Up to what voltage is 5 A available?

At 5 A, the power limit restricts voltage to 660 V. Above this voltage, maximum available current decreases according to 3,300 W divided by the output voltage.

Which mains connection is required?

pvServe operates from 230 V AC. The supplying circuit should have 16 A overcurrent protection.

How is the unit operated and connected on the DC side?

Operation is via a graphic display. The positive and negative DC output connections use 4 mm banana plugs.

Is reverse-current thermography possible at night?

Yes. Controlled current injection enables thermal imaging for hotspot detection without the solar irradiance otherwise required. A thermal imaging camera is needed for the images.

Can pvServe be used for electroluminescence imaging?

Yes. The power supply injects current into the solar modules; an additional infrared camera suitable for electroluminescence enables imaging to detect microcracks.

Can an inverter be commissioned without an installed solar array?

Yes. pvServe can provide DC power for this commissioning task. Required voltage and current operating points must remain within the output range and the 3.3 kW power limit.

Technical consultation and project enquiry

To plan your pvServe application, tell us the module type, number of modules per string, required voltage and desired test current. Include the intended inspection method, available camera equipment or inverter type, and the available mains supply.