Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
NXI-F1010

Description
NXI-F1010 Single-slot NXI measurement and control chassis, 1 slot for 4HP module, LAN/CAN, desktop and ATE integration
NXI-F1010
NXI-F1010 Single-slot NXI measurement and control chassis, 1 slot for 4HP module, LAN/CAN, desktop and ATE integration
NXI Chassis

Technical Data

NXI Category

Measurement and control chassis

NXI-F1020

Description
NXI-F1020 Dual-slot NXI measurement and control chassis, 2 slots for 4HP modules or 1 slot for 8HP module, LAN/CAN
NXI-F1020
NXI-F1020 Dual-slot NXI measurement and control chassis, 2 slots for 4HP modules or 1 slot for 8HP module, LAN/CAN
NXI Chassis

Technical Data

NXI Category

Measurement and control chassis

NXI-F1030

Description
NXI-F1030 Multi-slot NXI measurement and control chassis, 9 slots, 2U, up to 500 W module power, LAN/CAN
NXI-F1030
NXI-F1030 Multi-slot NXI measurement and control chassis, 9 slots, 2U, up to 500 W module power, LAN/CAN
NXI Chassis

Technical Data

NXI Category

Measurement and control chassis

NXI-F1080

Description
NXI-F1080 Multi-slot NXI measurement and control chassis, 17 slots, 4U, up to 1000 W module power, LAN/CAN
NXI-F1080
NXI-F1080 Multi-slot NXI measurement and control chassis, 17 slots, 4U, up to 1000 W module power, LAN/CAN
NXI Chassis

Technical Data

NXI Category

Measurement and control chassis

NXI-F10xx measurement and control chassis overview

NXI-F1010, NXI-F1020, NXI-F1030 and NXI-F1080 are chassis for compatible modular NXI measurement and control instruments. They provide slots, power, cooling, and LAN and CAN connections. This allows users to build both single-module desktop setups and multichannel automated test systems on the same platform. F1010 accommodates one 4HP module; F1020 accommodates two 4HP modules or one 8HP module. The 19-inch F1030 and F1080 offer nine and 17 slots respectively on a 4HP pitch. One slot in each of these models is intended for a control module, leaving eight or 16 slots for function modules. Selection therefore depends on module width, the required number of function modules, their combined power demand and the desired mounting format. Measurement ranges, accuracy and test routines are determined by the installed modules, rather than the chassis alone.

Key benefits

Choose the right size

Four chassis sizes cover a single desktop slot through a 17-slot rack, so the system can match the required module count.

Accommodate wider modules

F1020 accommodates either two 4HP modules or one 8HP module while keeping the desktop setup compact.

Connect over a network

Gigabit Ethernet ports connect the chassis to a host computer and support integration of compatible modules into automated test stations.

Electrical slot isolation

Electrical isolation between the respective slots is specified for F1020, F1030 and F1080.

Trigger modules together

F1030 and F1080 support synchronous triggering of multiple modules and provide connections for external trigger signals.

Mount in a rack

F1030 and F1080 are 19-inch chassis in 2U and 4U formats, with front and rear rack mounting support.

How the NXI chassis work

The chassis connect installed NXI modules to power and communication through the backplane. LAN and CAN are available for control and automation. The measurement, source, load or control function itself is provided by a compatible function module. The architecture of F1030 and F1080 provides for one control module and up to eight or 16 function modules respectively. Synchronous triggering specified for these two models supports coordinated operation across multiple modules.

Models and technical selection

ModelSlots / modulesModule powerFormat
NXI-F10101 × 4HP; incompatible with NXI-3106 and NXI-3201External 12 V DC for chassis and fanDesktop; 26.7 × 132.5 × 196.7 mm (H × W × D)
NXI-F10202 × 4HP or 1 × 8HPIntegrated; module load up to 200 WDesktop; 44.5 × 170 × 275 mm (H × W × D)
NXI-F10309 × 4HP; 1 control module + up to 8 function modulesIntegrated; module load up to 500 W19-inch, 2U; front or rear rack mounting
NXI-F108017 × 4HP; 1 control module + up to 16 function modulesIntegrated; module load up to 1,000 W19-inch, 4U; front or rear rack mounting

These wattage figures describe the load from installed modules that each chassis supports. They are not the output power of a measurement or power module. Check each planned combination against module compatibility and power demand.

Interfaces and system integration

FeatureModelsFunction
Gigabit Ethernet / LANAll fourNetwork connection to a host computer; F1020 has separate LAN connections for its two module positions.
CANAll fourCAN communication; F1010, F1030 and F1080 document switchable 120-ohm termination. F1020 provides CAN connections for cascading.
Synchronous triggeringF1030, F1080Coordinated control of several modules. External trigger inputs are described for both rack models.

Mounting, power and cooling

F1010 uses separate 12 V DC connections for main operation and the fan. F1020, F1030 and F1080 have AC mains connections; their manuals specify 220 V AC. The two rack models use temperature-controlled fans; F1010 has a blow-through fan and F1020 an intelligent fan. Integration planning should account for airflow, the supply requirements of the chosen module combination and mechanical mounting. Modules must not be inserted or removed while power is applied to any of the four chassis.

Typical applications

Desktop tests with individual modules

F1010 and F1020 accommodate one or two narrow NXI modules respectively for compact laboratory setups.

Multichannel measurement systems

F1030 and F1080 combine up to eight or 16 function modules respectively in a 19-inch chassis.

Coordinated module operation

F1030 and F1080 support synchronous triggering when several installed modules need coordinated operation.

Frequently asked questions

Do the chassis contain measurement modules?

The chassis provide the platform. Measurement or control functions depend on separately selected, compatible NXI modules.

Which chassis accepts an 8HP module?

F1020 is documented to accept one 8HP module instead of two 4HP modules.

How many function modules fit in the rack models?

F1030 provides eight and F1080 16 function-module positions; one additional slot in each is intended for the control module.

Do all chassis need an external 12 V supply?

No. F1010 uses 12 V DC; F1020, F1030 and F1080 have an AC mains connection and integrated module power.

Are all NXI modules compatible with F1010?

No. NXI-3106 and NXI-3201 are expressly excluded for F1010. Check other combinations against the respective module requirements.

Can I exchange modules while power is on?

No. Disconnect power before inserting or removing modules.

Which chassis can be used in automated test systems?

All four models are described for integrated test setups; F1030 and F1080 additionally provide many function-module positions for multichannel systems.

Can I make a compact laboratory setup?

Yes. F1010 and F1020 are described for desktop tests and occupy only one or two 4HP module positions.

Technical consultation and project enquiry

Choosing a chassis calls for the module series and width, number of function modules, combined power demand, communication path and mounting format. Tell us about your planned system configuration.

Discuss your NXI system with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly