NXI-6700-4 Multi-channel DC voltage measurement module, 4 channels, ±600 V, 0.025 % accuracy, LAN/CAN
NXI-6700-4
NXI-6700-4 Multi-channel DC voltage measurement module, 4 channels, ±600 V, 0.025 % accuracy, LAN/CAN
NXI Module Card

Technical Data

NXI Category

Meas. & DAQ Modules

Product category

NXI Measurement & Test Systems

NXI-6700-4 DC voltage measurement module overview

The NXI-6700-4 is a four-channel module for simultaneous DC voltage acquisition. Each channel is connected across the voltage source under test using its positive and negative terminals. The ±6 V, ±60 V and ±600 V ranges cover different signal levels, with corresponding resolutions of 0.1 mV, 1 mV and 10 mV. Basic accuracy is 0.025% of reading plus 0.025% of full scale. This specification applies within one year of calibration, at 18–28 °C and up to 80% relative humidity. The manual specifies a 30-minute preparation period for precision measurements. The slim module occupies one NXI-F1000 chassis slot and can also operate independently with an external 12 V supply and LAN connection.

Key benefits

Simultaneous acquisition

Four DC voltages are measured in one module, reducing the number of separate instruments in the setup.

Three measurement ranges

±6 V, ±60 V and ±600 V accommodate different voltage levels.

Specified accuracy

Basic accuracy of 0.025% + 0.025% of full scale supports measurement planning against a defined specification.

Selectable reading rate

Three levels from 2 to 50 readings per second adapt acquisition to the task.

Separate channels

Electrical isolation between channels supports measurements at separate potentials; no isolation voltage is specified.

Modular form factor

One NXI-F1000 chassis slot or independent operation accommodates different measurement setups.

Measurement principle and technical data

Each of the four input pairs is connected across the device under test. The module measures DC voltage; it does not generate a test voltage. The maximum permissible input values must be observed when selecting ranges and wiring the system.

ParameterNXI-6700-4
Channels4, simultaneous voltage measurement
DC ranges−6 to +6 V; −60 to +60 V; −600 to +600 V
Resolution by range0.1 mV; 1 mV; 10 mV
Basic accuracy0.025% of reading + 0.025% of full scale
Temperature coefficient40 ppm/°C
Reading rateFast: 50/s; medium: 8/s; slow: 2/s
Supply12 V DC ±10%
Dimensions130.5 × 20 × 230.5 mm, including puller

Accuracy conditions: within one year of calibration, at 18–28 °C and up to 80% relative humidity; allow 30 minutes of preparation for precision measurements.

Applications

Automotive electronics

Acquire DC voltages at four points of an automotive electronic assembly simultaneously.

Home appliances

Monitor DC voltages at several points of an appliance in a test setup.

Integrated test systems

Integrate four measurement channels into a larger acquisition system via LAN or CAN.

Interfaces and software

ElementFunction
Measurement connectorPlug-in 8-pin connector for four positive/negative input pairs
LANRJ45 connector for independent operation and PC connection
CANCAN bus communication with switchable 120 Ω termination
ProtocolsSCPI, Modbus RTU and CANopen are supported
NXI DAQ & Meas.Configuration, acquisition and recording via PC software
NXI-DAQ librariesC# and LabVIEW functions and examples for custom software integration

Installation and operation

In the NXI-F1000 chassis, the module uses the backplane connector for power and communication. Independent operation requires a suitable 12 V DC supply and LAN connection. The operating temperature is 0–40 °C; the specified environment is below 2,000 m altitude and 5–90% relative humidity without condensation. Measurement leads should be short and routed away from interference sources. External voltage must not exceed the 600 V DC measurement limit.

NXI-6700-4 FAQ

How many voltages can one module measure?

Four DC voltages can be acquired simultaneously using four separate input pairs.

Which measurement ranges are available?

The stated bipolar DC ranges are ±6 V, ±60 V and ±600 V.

Which reading rates are available?

Fast, medium and slow correspond to 50, 8 and 2 readings per second.

Can the module operate without a chassis?

Yes. Independent operation with a 12 V DC supply and LAN connection is supported.

Under which conditions does the accuracy apply?

Within one year of calibration, at 18–28 °C and up to 80% relative humidity.

Can it be used for automotive electronics?

Yes, this application is listed. The module acquires DC voltages; wiring must comply with its input limits.

Can it be integrated into test systems?

Yes, this application is listed; LAN/CAN and NXI-DAQ libraries support integration.

Technical consultation and project enquiry

Selecting the NXI-6700-4 calls for the required voltage ranges, number of measurement points, reading rate, channel potentials and planned LAN or CAN integration.