Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
NXI-6110-8

Description
NXI-6110-8 High-accuracy analog input module, 8 channels, ±60 V, optional up to 2000 V / ±1000 A, 100 kS/s
NXI-6110-8
NXI-6110-8 High-accuracy analog input module, 8 channels, ±60 V, optional up to 2000 V / ±1000 A, 100 kS/s
NXI Module Card

Technical Data

NXI Category

Meas. & DAQ Modules

Product category

NXI Measurement & Test Systems

NXI-6110-8 analog input module overview

The NXI-6110-8 is an eight-channel data acquisition module for analog voltages. Each channel offers five bipolar ranges from ±200 mV to ±60 V; the maximum sampling rate is 100 kS/s per channel or 800 kS/s in total. Each input has an SMB connector. Isolation is specified as 300 V DC between channels and DC 1,500 V (CAT II) or AC 1,000 V (CAT II) from channel to ground. A separately available NXI-6110-DV high-voltage divider and current sensor enable measurement of DC voltage, DC current and calculated DC power. The module occupies one slot in the NXI-F1000 chassis or operates independently with a 12 V DC supply. Trigger functions, LAN/CAN and NXI software support integration into measurement and test systems.

Key benefits

Eight isolated inputs

Eight isolated analog channels acquire several measurement points in one module; 300 V DC channel-to-channel isolation is specified.

Fast sampling

Up to 100 kS/s per channel and 800 kS/s in total support acquisition of changing signals.

Selectable input ranges

The ±200 mV, ±1 V, ±6 V, ±10 V and ±60 V ranges allow settings matched to different signal levels.

Triggered acquisition

Multichannel triggering, pre- and post-trigger acquisition and adjustable delay relate samples to an event.

Extended DC measurement

Optional dividers and current sensors extend measurement to 0–2,000 V and, depending on the sensor, up to ±1,000 A.

Flexible form factor

The module uses one NXI-F1000 slot and alternatively supports independent operation with a 12 V DC supply.

Measurement principle and accuracy

The eight SMB inputs acquire analog voltage signals. An appropriate range is selected for each channel. In the ±200 mV range, resolution is 10 µV and specified accuracy is ±0.2 mV at 25 ±5 °C and 1 kS/s. Other ranges have their own resolution and accuracy specifications; one accuracy value must therefore not be applied to every range or sampling rate.

For 0–2,000 V DC, a channel in the ±1 V range is combined with the optional NXI-6110-DV divider. For DC current, a channel in the ±10 V range is used with a suitable external current sensor. DC power is calculated from measured voltage and current; a measurement range up to 2 MW is specified. The accuracy of extended measurements also depends on the divider or sensor.

Technical data and measurement ranges

ParameterNXI-6110-8
Analog inputs8 isolated channels, SMB
Direct input±200 mV, ±1 V, ±6 V, ±10 V, ±60 V; maximum range ±64 V
Resolution10 µV in the ±200 mV range; 0.1 mV in the other ranges
Accuracy±0.2 mV in the ±200 mV range at 25 ±5 °C and 1 kS/s
Sampling rateUp to 100 kS/s per channel; up to 800 kS/s in total
DC high voltage with option0–2,000 V with NXI-6110-DV and a channel in the ±1 V range
DC current with optionSensor-dependent ranges from ±20 A to ±1,000 A; channel in the ±10 V range
DC power measurement0–2 MW calculated from DC voltage and DC current measurements
Isolation300 V DC channel to channel; channel to ground: DC 1,500 V (CAT II) / AC 1,000 V (CAT II)
Acquisition memory4 MB × 8
Data update intervalAdjustable from 1 ms to 10 s

Triggering and acquisition sequences

The software allows selection of channels, ranges, sampling frequency and sample count. Documented acquisition modes include starting after a trigger event, delayed acquisition and pre-trigger acquisition. For an internal trigger, settings include edge, level and hysteresis. An external clock source must be connected to the NXI chassis; its connectors are described in the relevant chassis manual.

Typical applications

High-voltage battery pack testing

Acquire voltage and current signals at several points in battery pack test setups; higher DC values require the optional transducers.

PV inverter testing

Record analog signals in photovoltaic inverter test setups and measure DC voltage and current using suitable external transducers.

HIL test systems

Acquire analog signals on several channels with triggering in hardware-in-the-loop systems.

Integrated test systems

Acquire several analog measurement points in an NXI system or through the independent LAN/CAN connection.

Interfaces and integration

EquipmentFunction
8 SMB connectorsAnalog inputs CH1 to CH8
LANCommunication and PC connection during independent operation
CANCAN control interface with selectable 120 Ω termination
SCPI, Modbus-RTU, CANopenSupported communication protocols; check the specific port assignment for the project
NXI-F1000 rear connectorCommunication, control and power in the chassis
NXI configuration softwareDevice discovery, channel configuration, acquisition start and display; gain and offset correction can be configured

Installation and operating conditions

The module measures 130.5 × 20.0 × 230.5 mm including the handle and weighs approximately 0.25 kg. Independent operation requires a 12 V DC ±10% supply at less than 1 A. The specified operating temperature is 0–40 °C, and relative humidity is 5–90% without condensation. Make connections only while power is off and observe the permitted input ranges.

Frequently asked questions

How many signals can one module acquire?

Eight analog voltage signals through eight isolated SMB inputs.

Can it measure 2,000 V directly?

No. This requires the optional NXI-6110-DV high-voltage divider on a channel set to the ±1 V range.

How is DC current measured?

With a suitable external current sensor on a channel in the ±10 V range; the sensor determines the current range.

Can the module operate without a chassis?

Yes, with a separate 12 V DC supply and LAN/CAN connection. An external clock is connected through an NXI chassis.

What does triggering do?

It starts or positions acquisition relative to an event, including pre-trigger and delayed acquisition.

What accuracy applies at ±200 mV?

±0.2 mV at 25 ±5 °C and 1 kS/s. Other ranges have separate specifications.

Is it suitable for battery pack testing?

Yes, for acquiring analog measurement signals. DC high-voltage and high-current measurements require suitable optional dividers and sensors.

Can it acquire signals in PV inverter tests?

Yes, in suitable test setups. It is an input module and does not simulate a PV array or power grid.

Is it intended for HIL setups?

Yes, for multichannel acquisition of analog signals with triggering in HIL test systems.

Technical consultation and project enquiry

Signal ranges, channel count, sampling rate, triggering and any required high-voltage dividers or current sensors determine the right configuration. Discuss your measurement setup with ET System.

Send a project enquiry to ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly