Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
NXI-6102-8/16

Description
NXI-6102-8/16 High-voltage analog input module, 8 channels, 16-bit, ±30 V, 800 kS/s, LAN/CAN
NXI-6102-8/16
NXI-6102-8/16 High-voltage analog input module, 8 channels, 16-bit, ±30 V, 800 kS/s, LAN/CAN
NXI Module Card

Technical Data

NXI Category

Meas. & DAQ Modules

Product category

NXI Measurement & Test Systems

NXI-6103-8/16

Description
NXI-6103-8/16 High-voltage analog input module, 8 channels, 16-bit, ±60 V, 800 kS/s, LAN/CAN
NXI-6103-8/16
NXI-6103-8/16 High-voltage analog input module, 8 channels, 16-bit, ±60 V, 800 kS/s, LAN/CAN
NXI Module Card

Technical Data

NXI Category

Meas. & DAQ Modules

Product category

NXI Measurement & Test Systems

NXI-6102/6103: High-Precision High-Voltage Analog Input Modules for Industrial Data Acquisition and Test Automation

The NXI-6102 and NXI-6103 are high-precision 16-bit analog input modules with eight channels for demanding measurement tasks in development, validation, and industrial quality assurance. Thanks to consistent galvanic isolation between the channels, these modules are ideal for test environments with high common-mode voltages and sensitive analog signals.

The combination of 8 isolated channels, up to 800 kS/s total sampling rate, and high-voltage measurement ranges up to ±60 V creates a safe and repeatable platform for dynamic data acquisition in modern test systems.

This allows both small sensor signals and higher voltages in complex test setups to be captured precisely, synchronously, and with high long-term stability.

Key Advantages

Up to 800 kS/s Total Sampling Rate
High-dynamic acquisition of transient events with up to 100 kS/s per channel for detailed fault analysis and fast signal transitions.
High Sensitivity for Small Signals
In the ±200 mV range, resolutions down to 0.1 µV are possible, making the modules ideal for shunt voltages, sensor values, and precise low-level signal measurements.
True Channel-to-Channel Isolation
Full inter-channel isolation up to 300 V DC enables safe measurements on battery stacks, series-connected cells, and systems with different potentials.
RAM
4 MB Memory per Channel
Hardware-based pre-trigger and post-trigger data logging captures critical events reliably even under high bus load and in complex test scenarios.
±V
Wide Measurement Range Coverage
One module covers measurement ranges from ±200 mV to ±60 V, reducing system effort, additional hardware, and integration complexity.
High Basic Accuracy
With 0.03% + 0.02% F.S. and a low temperature coefficient, measurement results remain reproducible even over long test cycles.

Typical Applications

The NXI-6102/6103 modules are suitable for applications where high voltage withstand capability, precise low-level signal resolution, and safe multi-channel data acquisition are required at the same time.

?
Automotive Electronics Testing

Validation of ECUs and components in 12 V, 24 V, and 48 V electrical systems, including load steps, quiescent currents, and transient events.

?
Industrial Process Control

Acquisition of analog sensor signals in dynamic production processes with different potentials and high susceptibility to interference.

?
Research and Education

Flexible signal analysis in academic test setups with high demands on precision, isolation, and scalability.

?
ATE Test Systems

Scalable data acquisition in automated test benches for series production, quality assurance, and end-of-line testing.

?
Battery and Cell Measurement

Safe measurement of series-connected cells and battery stacks thanks to true channel isolation and high measurement dynamics.

?
Shunt and Sensor Signals

Precise acquisition of the smallest voltage drops and analog sensor signals in the mV and µV range.

Key Technical Data

Input Channels 8 channels, channel-to-channel isolated
Connection Type SMB terminal
Resolution 16-bit
Measurement Ranges NXI-6102: ±30 V, NXI-6103: ±60 V, plus ±10 V, ±5 V, ±1 V, and ±200 mV
Max. Headroom ±32 V for the NXI-6102, ±64 V for the NXI-6103
Smallest Resolution 0.1 µV in the ±200 mV range

Measurement Performance and Electrical Data

Input Impedance greater than 1 MΩ
Sampling Rate 800 kS/s total, maximum 100 kS/s per channel
Accuracy 0.03% + 0.02% F.S. at 25 ±5 °C
Inter-Channel Isolation 300 V DC
Operating Voltage 12 V DC ±10%, below 1 A
Dimensions 130.5 mm × 20.0 mm × 230.5 mm

Functional Concept and System Architecture

The NXI-6102/6103 series is designed for maximum flexibility in test benches and can be used both in the NXI-F1000 chassis and as a standalone unit.

Chassis Operation Integration into the NXI-F1000 system with synchronization via the backplane
Standalone Operation Use as a compact measurement black box via 12 V DC supply
Clock Sources Internal and external clock source for precise time correlation
Communication Hybrid interface concept via LAN and CAN
Memory Management 4 MB per channel for pre-trigger and post-trigger data recording
Safety Concept Channel isolation protects the user, the DUT, and downstream electronics from potential differences

Variants and Configuration Options

The key difference between the two models lies in the maximum input voltage. This allows the right module to be selected specifically for the respective application and required voltage margin.

NXI-6102 Maximum range up to ±32 V, nominal high-voltage range ±30 V
NXI-6103 Maximum range up to ±64 V, nominal high-voltage range ±60 V
48 V Systems NXI-6103 offers additional reserve for transient overvoltage events
Shared Platform Identical hardware base in the smaller measurement ranges from ±10 V to ±200 mV
Software Compatibility Same API and identical driver structure for both variants
Test Bench Flexibility Both modules can be combined consistently within one system

Integration and Automation

For Industry 4.0 and ATE applications, the NXI-6102/6103 modules support Modbus RTU, SCPI, and CANopen protocols as standard. This enables direct integration into PLC systems, LabVIEW environments, and proprietary test software.

The single-slot format allows precise scaling of the channel count, ensuring that the architecture remains consistent and easy to maintain from a single module up to a fully populated chassis.

Whether used as a standalone unit via LAN or as part of a modular high-channel-count system, integration remains consistent and future-proof.

Environmental Conditions and Long-Term Stability

The modules are designed for industrial operating conditions and work reliably at altitudes below 2000 m, humidity levels from 5% to 90% non-condensing, and air pressure from 80 to 110 kPa.

A low temperature coefficient of 30 ppm/°C ensures that measurement accuracy remains stable even during longer test cycles or changing environmental conditions, without requiring frequent recalibration.

Strategic Added Value

The NXI-6102/6103 series combines precise high-voltage data acquisition, true channel isolation, and flexible system integration in a compact analog input module for modern test environments.

With its scalable architecture, robust isolation technology, and consistent software platform, it provides a future-proof investment for development, automation, and industrial quality assurance.

Consulting and Contact

Are you unsure whether this product is the best fit for your application? We will be happy to support you in selecting the right solution for your requirements – from a single application to complete system integration. Contact us conveniently via live chat, the contact form, email, or phone – we provide personal, practical advice tailored to your needs. Depending on availability, we can also provide you with a free demo unit for evaluation in your test environment, allowing you to test the system directly under real operating conditions.

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly