Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
NXI-4301-1/48

Description
NXI-4301-1/48 multiplexer switch module, 48 nodes, 60 VDC/30 VAC, 1 A, 30 W, 100 CH/s, LAN/CAN.
NXI-4301-1/48
NXI-4301-1/48 multiplexer switch module, 48 nodes, 60 VDC/30 VAC, 1 A, 30 W, 100 CH/s, LAN/CAN.
NXI Module Card

Technical Data

NXI Category

Digital I/O modules

Product category

NXI Measurement & Test Systems

NXI-4301 multiplexer switch module overview

The NXI-4301-1/48 is a 48-node switching module for automated selection of measurement paths. Relays connect the selected channels to common terminals; the module does not generate or measure signals itself. Six documented wiring configurations cover one-, two- and four-wire signal routing. These include a four-wire topology for resistance measurements and a two-wire matrix using the optional NXI-TB2606 terminal box. The module occupies one slot in an NXI-F1000 chassis and can also operate independently from a 12 V DC supply. LAN and CAN enable integration into controlled test sequences. The switching limits of 30 V AC or 60 V DC, 1 A and 30 W apply to the module and switched path; they do not specify the accuracy of a connected measuring instrument.

Key benefits

Multiple test points

The 48 nodes allow selection among 48 signal paths in the one-wire topology with one module.

Four-wire routing

The 4-wire 12×1 topology connects twelve channels to the common terminal for resistance measurements with external equipment.

Sequential testing

The specified scan rate of 100 channels/s supports switching among multiple test points.

Signal bandwidth

Switch bandwidth is 10 MHz with 50 Ω termination; this condition matters for the complete measurement chain.

Remote operation

LAN and CAN interfaces and the described PC software support integration into controlled test setups.

Expandable matrix

The NXI-TB2606 enables a 2-wire 4×6 matrix; multiple modules and terminal boxes can form larger matrices.

Topologies and technical data

The selected topology determines which channels can reach the common terminals. The 4×6 matrix requires the optional NXI-TB2606; the remaining multiplexer configurations use the appropriate wiring and relay configuration.

ParameterNXI-4301-1/48
Topologies1-wire 48×1; 2-wire 24×1; dual 2-wire 12×1; quad 2-wire 6×1; 4-wire 12×1; 2-wire 4×6 matrix with NXI-TB2606
Maximum switching ratings30 V AC / 60 V DC; 1 A; 30 W
Minimum switch load10 µA, 10 mV
DC path resistanceInitial < 1 Ω; final 2 Ω
Thermoelectric EMF< 12 µV
Bandwidth10 MHz with 50 Ω termination
Scan rate100 channels/s
Signal connector68-pin SCSI-II female connector
Operating supply12 V DC ±10%, < 2 A for independent operation
Dimensions130.5 × 20 × 230.5 mm including puller
Operating temperature0 to 40 °C

Applications

Four-wire resistance measurements

The 4-wire 12×1 topology routes twelve test points to a suitable external resistance meter.

Multichannel data acquisition

Signals from several channels are connected to the common measurement terminal in sequence.

Interfaces and operation

The PC software provides device discovery, topology selection, relay control and status display. Independent operation uses 12 V DC and LAN; in the NXI-F1000 chassis the rear connector provides integration. Modbus-RTU, SCPI and CANopen are listed as protocols; the protocol assignment to specific interfaces should be confirmed during system integration. For matrix expansion, two modules and two NXI-TB2606 boxes are specified for 4×12, or three modules and three boxes for 12×6.

Frequently asked questions

Does the module measure signals?

No. It switches signal paths; a connected instrument performs the measurement.

Is the 4×6 matrix available without accessories?

This topology requires the NXI-TB2606 terminal box.

Can the module operate independently?

Yes, with 12 V DC ±10% and current consumption below 2 A; communication can use LAN.

Can it route four-wire resistance measurements?

The 4-wire 12×1 topology routes twelve test points to external measurement equipment. Accuracy depends on the complete setup.

What is the scan rate?

The specified scan rate is 100 channels per second.

What are the switching limits?

The limits are 30 V AC or 60 V DC, 1 A and 30 W; all limits must be observed together.

Technical consultation and project enquiry

We can help select the topology, terminal box and signal ratings and plan integration into your test setup.

Discuss your project

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly