Eight fixed DI channels acquire states and signals; eight DO channels switch levels or generate PWM.
NXI-4102 – Digital I/O Module up to 40 V with 8 Inputs and 8 Outputs
For ECU testing with PWM inputs and outputs and synchronous acquisition of multiple signal channels.
The NXI-4102-8/8 combines eight digital inputs with eight digital outputs for PWM signals in the 3.3 to 40 V level range. The dual-slot module operates in an NXI-F1000 chassis or independently with a 12 V supply and LAN connection. This supports both modular measurement systems and individual test stations.
Up to 20 MS/s is available in total; with eight channels acquired simultaneously, the maximum is 2.5 MS/s per channel.
In addition to individual PWM outputs, complementary output pairs with adjustable dead time are available.
Frequency measurement, direct level reading and streaming acquisition support analysis of digital control signals.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
NXI-4102-8/8 high-voltage I/O module, 8 PWM inputs, 8 PWM outputs, 3.3–40 V, 1 Hz–100 kHz, LAN/CAN.
|
Technical Data
NXI Category
Digital I/O modules
Product category
NXI Measurement & Test Systems
NXI-4102-8/8 overview
The NXI-4102-8/8 is a programmable high-voltage digital I/O module based on the NXI architecture. It provides eight fixed inputs and eight fixed outputs; channel direction cannot be reassigned. The inputs acquire digital states, PWM signals, frequency and duty cycle. The outputs provide digital levels as well as individual or complementary PWM signals. The signal level range is 3.3 to 40 V. Outputs use an internal 24 V supply or an external 3.3 to 40 V supply; output current is specified at no more than 100 mA per channel. The dual-slot module can operate in an NXI-F1000 chassis or independently with a 12 V DC supply and LAN. It is intended for digital signal acquisition and control in controller, industrial and integrated test systems.
Key benefits
Connect signals in parallel
Eight inputs and eight outputs combine digital acquisition and control in one module.
Acquire fast level changes
Streaming acquires up to 20 MS/s in total; the rate is shared among simultaneously used input channels.
Generate complementary signals
PWM output pairs can be configured with a dead time from 0 to 0.65535 ms.
Evaluate frequency and duty cycle
The inputs measure frequencies from 1 Hz to 100 kHz and capture duty cycle within a frequency-dependent range.
Standalone or in a chassis
The module occupies two slots in the NXI-F1000 or operates with an external 12 V supply via LAN.
Integrate into test software
NXI-DAQ libraries and C# and LabVIEW examples support custom control and acquisition workflows.
How the digital I/O module works
Inputs DI1 to DI8 are used for level reading, streaming acquisition and frequency measurement. These functions share the same input channels. Outputs DO1 to DO8 are used for direct level output or PWM; these modes also use the same terminals. Complementary PWM signals are configured as output pairs with adjustable dead time. Channel direction is fixed and cannot be reassigned.
Channels and technical data
| Model | Inputs | Outputs | Frequency range |
|---|---|---|---|
| NXI-4102-8/8 | 8 DI, 3.3–40 V | 8 DO, internal 24 V or external 3.3–40 V; ≤100 mA/channel | Measurement and output: 1 Hz–100 kHz |
The maximum safe voltage is specified as ≤42 V. Frequency measurement accuracy is 1% F.S. at 100 kHz, 0.1% F.S. at 10 kHz and 0.01% F.S. at 1 kHz. Frequency output accuracy at the same points is 0.1%, 0.01% and 0.001% F.S., respectively.
Sampling and programmable functions
Up to 20 MS/s is specified for one input; the total sampling rate remains 20 MS/s. With eight inputs acquired simultaneously, the maximum is therefore 2.5 MS/s per channel. The streaming display buffers up to 10,000 points. In a chassis, streaming acquisition can be triggered by an external signal at the chassis interface on a rising or falling edge.
| Function | Operation |
|---|---|
| Direct input and output | Read digital input levels and set output levels; the output state after power-up is configurable. |
| Streaming | Acquire one, two, four or eight inputs using an internal or external sampling clock. |
| Frequency measurement | Configure measurement window and noise rejection time for selected inputs. |
| PWM output | Set period, high time, delay, initial level, pulse count and trigger mode. |
| Complementary PWM | Operate output pairs with adjustable dead time and defined initial states. |
Typical applications
I/O signal acquisition
Acquire digital levels and PWM signals, measure frequency and analyse the results.
Automotive and consumer controllers
Read digital control signals from controllers or stimulate them with level and PWM outputs.
Industrial controls
Acquire digital states and include PWM outputs in measurement and control workflows.
Integrated test systems
Integrate I/O acquisition, frequency measurement and signal output into automated test workflows with NXI-DAQ.
Interfaces and integration
| Equipment | Function |
|---|---|
| LAN | Network communication and standalone module control. |
| CAN | Bus communication with switchable 120 Ω termination. |
| NXI backplane | Communication, control and power distribution in the chassis. |
| Protocols | Modbus RTU, SCPI and CANopen are supported; the assignment to each interface should be checked during integration. |
| NXI-DAQ | Libraries and examples for custom applications with C# and LabVIEW. |
Installation and power
The module occupies two slots in the NXI-F1000 chassis. For standalone operation, a 12 V DC ±10% supply drawing less than 2.5 A is specified. Dimensions including the puller are 130.5 × 40 × 230.5 mm. The specified operating temperature range is 0 to 40 °C; relative humidity is 5 to 90% without condensation.
Frequently asked questions
Can channel direction be changed?
No. Eight channels are fixed as inputs and eight as outputs.
Does 20 MS/s apply to each input?
Only when acquiring one channel. The total limit is 20 MS/s; with eight channels, the maximum is 2.5 MS/s per channel.
Which output levels are available?
24 V with the internal supply, or 3.3 to 40 V with an external supply; no more than 100 mA per channel.
Can the module operate alone?
Yes, with an external 12 V DC supply and LAN. Alternatively, it can be installed in the NXI-F1000 chassis.
Can an external trigger be used?
Yes, for streaming acquisition when the module is installed in a chassis and the trigger is connected to its interface.
Is it suitable for controller signals?
Yes, for compatible digital levels and PWM signals within the specified voltage, current and frequency limits.
Can it be integrated into test systems?
Yes. LAN, CAN, the NXI backplane and NXI-DAQ support integration into custom measurement and control workflows.
Technical consultation and project enquiry
For selection, please specify signal levels, channel count, required sampling rate per channel, PWM parameters and whether the module will be used in a chassis or independently. Discuss your test setup with ET System.