Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
NXI-4102-8/8

Description
NXI-4102-8/8 high-voltage I/O module, 8 PWM inputs, 8 PWM outputs, 3.3–40 V, 1 Hz–100 kHz, LAN/CAN.
NXI-4102-8/8
NXI-4102-8/8 high-voltage I/O module, 8 PWM inputs, 8 PWM outputs, 3.3–40 V, 1 Hz–100 kHz, LAN/CAN.
NXI Module Card

Technical Data

NXI Category

Digital I/O modules

Product category

NXI Measurement & Test Systems

NXI-4102-8/8 overview

The NXI-4102-8/8 is a programmable high-voltage digital I/O module based on the NXI architecture. It provides eight fixed inputs and eight fixed outputs; channel direction cannot be reassigned. The inputs acquire digital states, PWM signals, frequency and duty cycle. The outputs provide digital levels as well as individual or complementary PWM signals. The signal level range is 3.3 to 40 V. Outputs use an internal 24 V supply or an external 3.3 to 40 V supply; output current is specified at no more than 100 mA per channel. The dual-slot module can operate in an NXI-F1000 chassis or independently with a 12 V DC supply and LAN. It is intended for digital signal acquisition and control in controller, industrial and integrated test systems.

Key benefits

Connect signals in parallel

Eight inputs and eight outputs combine digital acquisition and control in one module.

Acquire fast level changes

Streaming acquires up to 20 MS/s in total; the rate is shared among simultaneously used input channels.

Generate complementary signals

PWM output pairs can be configured with a dead time from 0 to 0.65535 ms.

Evaluate frequency and duty cycle

The inputs measure frequencies from 1 Hz to 100 kHz and capture duty cycle within a frequency-dependent range.

Standalone or in a chassis

The module occupies two slots in the NXI-F1000 or operates with an external 12 V supply via LAN.

Integrate into test software

NXI-DAQ libraries and C# and LabVIEW examples support custom control and acquisition workflows.

How the digital I/O module works

Inputs DI1 to DI8 are used for level reading, streaming acquisition and frequency measurement. These functions share the same input channels. Outputs DO1 to DO8 are used for direct level output or PWM; these modes also use the same terminals. Complementary PWM signals are configured as output pairs with adjustable dead time. Channel direction is fixed and cannot be reassigned.

Channels and technical data

ModelInputsOutputsFrequency range
NXI-4102-8/88 DI, 3.3–40 V8 DO, internal 24 V or external 3.3–40 V; ≤100 mA/channelMeasurement and output: 1 Hz–100 kHz

The maximum safe voltage is specified as ≤42 V. Frequency measurement accuracy is 1% F.S. at 100 kHz, 0.1% F.S. at 10 kHz and 0.01% F.S. at 1 kHz. Frequency output accuracy at the same points is 0.1%, 0.01% and 0.001% F.S., respectively.

Sampling and programmable functions

Up to 20 MS/s is specified for one input; the total sampling rate remains 20 MS/s. With eight inputs acquired simultaneously, the maximum is therefore 2.5 MS/s per channel. The streaming display buffers up to 10,000 points. In a chassis, streaming acquisition can be triggered by an external signal at the chassis interface on a rising or falling edge.

FunctionOperation
Direct input and outputRead digital input levels and set output levels; the output state after power-up is configurable.
StreamingAcquire one, two, four or eight inputs using an internal or external sampling clock.
Frequency measurementConfigure measurement window and noise rejection time for selected inputs.
PWM outputSet period, high time, delay, initial level, pulse count and trigger mode.
Complementary PWMOperate output pairs with adjustable dead time and defined initial states.

Typical applications

I/O signal acquisition

Acquire digital levels and PWM signals, measure frequency and analyse the results.

Industrial controls

Acquire digital states and include PWM outputs in measurement and control workflows.

Integrated test systems

Integrate I/O acquisition, frequency measurement and signal output into automated test workflows with NXI-DAQ.

Interfaces and integration

EquipmentFunction
LANNetwork communication and standalone module control.
CANBus communication with switchable 120 Ω termination.
NXI backplaneCommunication, control and power distribution in the chassis.
ProtocolsModbus RTU, SCPI and CANopen are supported; the assignment to each interface should be checked during integration.
NXI-DAQLibraries and examples for custom applications with C# and LabVIEW.

Installation and power

The module occupies two slots in the NXI-F1000 chassis. For standalone operation, a 12 V DC ±10% supply drawing less than 2.5 A is specified. Dimensions including the puller are 130.5 × 40 × 230.5 mm. The specified operating temperature range is 0 to 40 °C; relative humidity is 5 to 90% without condensation.

Frequently asked questions

Can channel direction be changed?

No. Eight channels are fixed as inputs and eight as outputs.

Does 20 MS/s apply to each input?

Only when acquiring one channel. The total limit is 20 MS/s; with eight channels, the maximum is 2.5 MS/s per channel.

Which output levels are available?

24 V with the internal supply, or 3.3 to 40 V with an external supply; no more than 100 mA per channel.

Can the module operate alone?

Yes, with an external 12 V DC supply and LAN. Alternatively, it can be installed in the NXI-F1000 chassis.

Can an external trigger be used?

Yes, for streaming acquisition when the module is installed in a chassis and the trigger is connected to its interface.

Is it suitable for controller signals?

Yes, for compatible digital levels and PWM signals within the specified voltage, current and frequency limits.

Can it be integrated into test systems?

Yes. LAN, CAN, the NXI backplane and NXI-DAQ support integration into custom measurement and control workflows.

Technical consultation and project enquiry

For selection, please specify signal levels, channel count, required sampling rate per channel, PWM parameters and whether the module will be used in a chassis or independently. Discuss your test setup with ET System.

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly