Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
NXI-3201-20-1

Description
NXI-3201-20-1 DC load module, 20 W, 20 V, 1 A, CC/CV/CR/CP, LAN.
Current [A]
1
Power [P]
20
Voltage [V]
20
NXI-3201-20-1
NXI-3201-20-1 DC load module, 20 W, 20 V, 1 A, CC/CV/CR/CP, LAN.
1
20
20
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-3201-60-1

Description
NXI-3201-60-1 DC load module, 50 W, 60 V, 1 A, CC/CV/CR/CP, LAN.
Current [A]
1
Power [P]
50
Voltage [V]
60
NXI-3201-60-1
NXI-3201-60-1 DC load module, 50 W, 60 V, 1 A, CC/CV/CR/CP, LAN.
1
50
60
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-3201-20-5

Description
NXI-3201-20-5 DC load module, 50 W, 20 V, 5 A, CC/CV/CR/CP, LAN.
Current [A]
5
Power [P]
50
Voltage [V]
20
NXI-3201-20-5
NXI-3201-20-5 DC load module, 50 W, 20 V, 5 A, CC/CV/CR/CP, LAN.
5
50
20
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-3201-60-5

Description
NXI-3201-60-5 DC load module, 50 W, 60 V, 5 A, CC/CV/CR/CP, LAN.
Current [A]
5
Power [P]
50
Voltage [V]
60
NXI-3201-60-5
NXI-3201-60-5 DC load module, 50 W, 60 V, 5 A, CC/CV/CR/CP, LAN.
5
50
60
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-3201-20-10

Description
NXI-3201-20-10 DC load module, 50 W, 20 V, 10 A, CC/CV/CR/CP, LAN.
Current [A]
10
Power [P]
50
Voltage [V]
20
NXI-3201-20-10
NXI-3201-20-10 DC load module, 50 W, 20 V, 10 A, CC/CV/CR/CP, LAN.
10
50
20
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-3201-100-1

Description
NXI-3201-100-1 DC load module, 25 W, 100 V, 1 A, CC/CV/CR/CP, LAN.
Current [A]
1
Power [P]
25
Voltage [V]
100
NXI-3201-100-1
NXI-3201-100-1 DC load module, 25 W, 100 V, 1 A, CC/CV/CR/CP, LAN.
1
25
100
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC Load

Modular Card

Benchtop Unit

NXI-1401-2 CAN communication converter overview

The NXI-1401-2 is a two-channel CAN communication converter module. It connects CAN devices to a PC or system controller via Ethernet and enables CAN messages to be sent and received over a network. CAN1 and CAN2 have separate connections and are isolated from each other. The specified isolation voltage is 2,000 V DC. Both channels support CAN 2.0A/B with baud rates from 5 kbit/s to 1 Mbit/s. An integrated 120 Ω termination resistor can be enabled in software when required. The module occupies one slot in an NXI-F1000 chassis; independent operation with a 12 V DC supply and LAN connection is also documented. This makes it a communication component for CAN-related test setups in automotive electronics, BMS testing and CAN device testing.

Key benefits

Two CAN connections

CAN1 and CAN2 are available in one module, allowing two bus connections to be integrated into a test setup.

Isolated channels

The channels are isolated from each other; the specified isolation voltage is 2,000 V DC.

Variable baud rate

The 5 kbit/s to 1 Mbit/s range allows adaptation to different CAN bus speeds.

Switchable termination

The integrated 120 Ω resistor is enabled in software when termination is required at the bus position.

CAN 2.0A/B

Standard and extended frames, plus data and remote frames, cover the documented CAN frame formats.

Two operating configurations

The plug-in module can be used in an NXI-F1000 chassis or separately with 12 V power and LAN.

Operating principle

The module links CAN-side communication to an Ethernet connection for control. A PC can send and receive CAN messages over the network. Configuration covers the baud rate, termination resistor status and CAN frame ID filtering. Each CAN channel uses a four-pin plug-in connector with GND, CANL, SHLD and CANH. Termination depends on the actual bus wiring; 120 Ω are used at each end of the bus.

Model and technical data

ModelCAN channelsBaud rateInter-channel isolationTermination resistor
NXI-1401-22 (CAN1, CAN2)5 kbit/s to 1 Mbit/s2,000 V DC120 Ω, software switchable

These figures apply to one NXI-1401-2 module.

CAN functions and configuration

FunctionImplementationUse
Frame formatStandard and extendedCommunication with CAN 2.0A/B devices
Frame typeData and remote framesExchange of the documented message types
Baud rateAdjustable from 5 kbit/s to 1 Mbit/sMatch the CAN bus speed
TerminationIntegrated 120 Ω, controlled in softwareBus termination without an external resistor when needed at the bus position
Frame ID filterCan be enabled and disabled through the interfaceSelection of received CAN messages

Typical applications

BMS testing

Send and receive CAN messages from a battery management system in a test setup.

CAN device testing

Exchange frames with a CAN device using a selected baud rate and optional termination.

Integrated test systems

Integrate two CAN connections as communication interfaces in an Ethernet-controlled test setup.

Interfaces, software and automation

ComponentEquipment or function
CAN1 and CAN2Two four-pin plug-in connectors; pin order GND, CANL, SHLD, CANH.
EthernetRJ45 LAN port for communication and device discovery on the local network.
Configuration and test toolDiscover devices, set CAN parameters, and send and receive CAN data.
Programming interfacesThe programming interface provides functions for baud rate, termination, frame ID filters, sending and receiving, plus C# and LabVIEW examples.

Installation and operating conditions

ItemNXI-1401-2
InstallationOne slot in the NXI-F1000 chassis or independent operation.
Supply in independent operation12 V DC ±10%; current draw <0.5 A.
Operating temperature0 to 40 °C.
Storage temperature−20 to 60 °C.
Environment5 to 90% relative humidity, non-condensing; altitude <2,000 m; air pressure 80 to 110 kPa.
Dimensions130.5 × 20 × 230.5 mm (H × W × D, with puller).

Frequently asked questions

Can the module be used without a chassis?

Yes. Independent operation uses a 12 V DC supply and a LAN connection.

How many CAN channels are available?

One NXI-1401-2 provides CAN1 and CAN2. The channels are isolated from each other.

Which CAN speeds are available?

The baud rate is adjustable from 5 kbit/s to 1 Mbit/s.

How is the CAN bus terminated?

Each channel has an integrated 120 Ω resistor that can be enabled in software. Termination must match the position on the bus.

Which CAN frames are supported?

CAN 2.0A/B support here includes standard and extended frames, plus data and remote frames.

Is frame ID filtering available?

The documented programming interface can enable and disable a CAN frame ID filter.

Can the module be used for BMS testing?

Yes, as a CAN communication interface for sending and receiving BMS messages in a test setup.

Is it suitable for CAN device testing?

Yes. CAN messages can be exchanged with a matching baud rate and bus termination.

Technical consultation and project enquiry

For integration of the NXI-1401-2, tell us the CAN baud rate, number of buses, required termination, chassis or independent operation, and PC connection requirements.

Contact ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly