Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
NXI-3106-15/4

Description
NXI-3106-15/4 DC-Netzteilmodul, 60 W, 15 V, 4 A, CC/CV, SEQ, LAN/CAN.
Current [A]
4
Power [P]
60
Voltage [V]
15
NXI-3106-15/4
NXI-3106-15/4 DC-Netzteilmodul, 60 W, 15 V, 4 A, CC/CV, SEQ, LAN/CAN.
4
60
15
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC source

Modular Card

Standard DC Source

Benchtop Unit

NXI-3106-30/2

Description
NXI-3106-30/2 DC-Netzteilmodul, 60 W, 30 V, 2 A, CC/CV, SEQ, LAN/CAN.
Current [A]
2
Power [P]
60
Voltage [V]
30
NXI-3106-30/2
NXI-3106-30/2 DC-Netzteilmodul, 60 W, 30 V, 2 A, CC/CV, SEQ, LAN/CAN.
2
60
30
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC source

Modular Card

Standard DC Source

Benchtop Unit

NXI-3106-60/1

Description
NXI-3106-60/1 DC-Netzteilmodul, 60 W, 60 V, 1 A, CC/CV, SEQ, LAN/CAN.
Current [A]
1
Power [P]
60
Voltage [V]
60
NXI-3106-60/1
NXI-3106-60/1 DC-Netzteilmodul, 60 W, 60 V, 1 A, CC/CV, SEQ, LAN/CAN.
1
60
60
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC source

Modular Card

Standard DC Source

Benchtop Unit

NXI-3106-6/12

Description
NXI-3106-6/12 DC power supply module, 60 W, 6 V, 12 A, CC/CV, SEQ, LAN/CAN.
Current [A]
12
Power [P]
60
Voltage [V]
6
NXI-3106-6/12
NXI-3106-6/12 DC power supply module, 60 W, 6 V, 12 A, CC/CV, SEQ, LAN/CAN.
12
60
6
NXI Module Card

Technical Data

NXI Category

Performance modules

Product category

NXI Measurement & Test Systems

Type of DC source

Modular Card

Standard DC Source

Benchtop Unit

NXI-3106 series overview

The NXI-3106 is a modular programmable DC power supply for integrated test systems and automated production testing. Each 4 HP module provides one 60 W channel. The model range comprises the NXI-3106-6/12 with 6 V and 12 A, NXI-3106-15/4 with 15 V and 4 A, NXI-3106-30/2 with 30 V and 2 A, and NXI-3106-60/1 with 60 V and 1 A. The module supports independent control or integration into NXI-F1080, NXI-F1030 and NXI-F1020 measurement and control chassis. A 4U chassis accommodates up to 16 channels. Constant-voltage, constant-current and constant-power operation are complemented by programmable sequences and selectable CC/CV priority. LAN and CAN, remote sense and supported automation protocols facilitate repeatable test routines.

Key benefits

High channel density

One channel occupies a single slot only 4 HP wide, while a 4U chassis accommodates up to 16 channels.

Four coordinated ranges

Four models combine 6, 15, 30 or 60 V with 12, 4, 2 or 1 A at 60 W each.

Priority matched to the DUT

Voltage priority limits voltage overshoot; current priority supports low-impedance DUTs and reduces current overshoot.

Repeatable test profiles

Up to 1,000 steps distributed across ten files program voltage, current and dwell time.

Regulation at the load

Two-wire and four-wire connections with remote sense measure voltage directly at the DUT.

Ready for automation

LAN and CAN plus SCPI, Modbus RTU and CANopen support integration into supervisory control systems.

How the programmable DC power supply works

The NXI-3106 delivers DC power and operates in constant-voltage or constant-current regulation according to load and setpoint. In CV mode it maintains the programmed voltage until the current limit is reached. In CC mode it limits the output to the programmed current. CP mode regulates output power over the range up to 60 W.

Selectable CC/CV priority adapts transient behavior to the DUT. Voltage priority provides a fast, smooth voltage rise with reduced voltage overshoot. Current priority is intended for low-impedance loads or applications where current overshoot must be avoided. The output supports two-wire and four-wire connections. A minimum voltage of 1 V is specified for remote compensation, and total power-supply output must not exceed 65 W under this condition.

Models, output ranges and accuracy

ModelOutputV / I resolutionV / I setting and readback accuracy
NXI-3106-6/120–6 V, 0–12 A, 60 W, 1 channel0.1 mV / 1 mA0.05% + 3 mV / 0.1% + 12 mA
NXI-3106-15/40–15 V, 0–4 A, 60 W, 1 channel1 mV / 0.1 mA0.05% + 8 mV / 0.1% + 4 mA
NXI-3106-30/20–30 V, 0–2 A, 60 W, 1 channel1 mV / 0.1 mA0.05% + 15 mV / 0.1% + 2 mA
NXI-3106-60/10–60 V, 0–1 A, 60 W, 1 channel1 mV / 0.1 mA0.05% + 30 mV / 0.1% + 1 mA

Accuracy conditions: The stated accuracies apply within one year after calibration, at 18–28 °C and up to 80% relative humidity. The tabulated values are specified at 23 ± 5 °C.

CP mode covers 0–60 W with 1 mW resolution; accuracy is 0.1% + 0.1% of full scale under the stated temperature conditions. A temperature coefficient of 50 ppm/°C is specified for voltage and current.

Dynamic performance and regulation

ParameterNXI-3106-6/12 and -15/4NXI-3106-30/2 and -60/1
Voltage rise, no load / full load≤ 20 ms / ≤ 20 ms≤ 30 ms / ≤ 30 ms
Voltage fall, no load / full load≤ 20 ms / ≤ 20 ms≤ 40 ms / ≤ 30 ms
Transient recovery time≤ 2 ms≤ 2 ms
Voltage ripple, 20 Hz–20 MHz≤ 10 mV RMS / ≤ 60 mV peak-to-peak≤ 10 mV RMS / ≤ 60 mV peak-to-peak
Current ripple, 20 Hz–20 MHz≤ 5 mA RMS / 20 mA peak-to-peak≤ 5 mA RMS / 20 mA peak-to-peak

Voltage line regulation is ≤ 0.01%, current line regulation ≤ 0.05%, and voltage load regulation ≤ 0.02%. Current load regulation is ≤ 0.05% for the NXI-3106-6/12 and ≤ 0.02% for the other models.

Operating modes and programmable functions

FunctionOperationBenefit in the test routine
CV / CC / CPConstant-voltage, constant-current or constant-power regulation up to 60 WDefine the DUT's electrical limits
CC/CV prioritySelect voltage or current priority for transient behaviorReduce overshoot according to load characteristics
SEQUp to 1,000 steps across ten files; voltage, current and dwell time per stepRun multi-stage routines repeatably
Resistance simulationConfigurable as a device system parameter in the PC applicationInclude resistance-related load behavior in the test setup
Batch ON/OFFSwitch multiple selected channels on and off together in the softwareOperate multi-channel routines efficiently
Data recordingAcquire voltage and current and save an NDAT file for analysisEvaluate test data after the run

Typical applications

Integrated test systems

The compact single-channel module powers DUTs within a modular NXI system. Remote control, sequences and remote sense support repeatable electrical functional tests.

Interfaces, software and system integration

EquipmentImplementationFunction
LANRJ45Network communication, device discovery and remote access within the same IP network
CANCAN-H, CAN-L and switchable 120 Ω terminationCommunication interface with adaptable bus termination
ProtocolsSCPI, Modbus RTU and CANopenProgrammatic control by supervisory systems
Rearplane40-pin ERmet B8 connectorConnection to the NXI chassis for communication, control and power
NXI chassisNXI-F1080, NXI-F1030 and NXI-F1020Integrated multi-channel operation; up to 16 channels in a 4U chassis
PC applicationDocumented for Windows 7 or laterHardware and channel configuration, multi-device selection, protection parameters, recording and analysis

Installation and operating conditions

CharacteristicRequirement or value
AC input220 V AC ± 10%, 47–63 Hz, input current ≤ 0.5 A
Dimensions with puller130.5 mm (H) × 20.0 mm (W) × 230.5 mm (D); module width 4 HP
Operating temperature0–40 °C
Storage temperature−20 to +60 °C
EnvironmentAltitude < 2,000 m; 5–90% relative humidity, non-condensing; 80–110 kPa
Output connectionPositive, negative, S+ and S− for remote sense; two-wire or four-wire connection

Before connection, verify the correct input voltage, protective earth and the permitted DUT operating range. Ventilation and cooling paths must remain unobstructed. The stated input current is not an external-fuse rating.

Protection functions

The NXI-3106 supports overvoltage, overcurrent, overpower and overtemperature protection (OVP, OCP, OPP and OTP). Protection limits for voltage, current and power can be configured in the PC application. Status indicators show operation, events, communication and power; the event indicator flashes in the event of a fault or alarm.

NXI-3106 FAQ

Which model matches my DUT?

Choose the required voltage and current range: 6 V/12 A, 15 V/4 A, 30 V/2 A or 60 V/1 A. All four versions provide 60 W and one channel.

How many channels fit in one chassis?

A 4U NXI chassis supports up to 16 NXI-3106 channels. Each 4 HP module occupies one slot and provides one output channel.

How large can a sequence be?

SEQ supports up to 1,000 steps distributed across ten files. Output voltage, output current and dwell time are defined for each step.

Which interfaces and protocols are available?

The module provides LAN and CAN. It supports SCPI, Modbus RTU and CANopen, and the CAN interface includes switchable 120 Ω termination.

When should voltage or current priority be used?

Voltage priority provides a smooth voltage rise with reduced voltage overshoot. Current priority is suitable for low-impedance DUTs or for limiting current overshoot.

Does the NXI-3106 support remote sense?

Yes. The output provides S+ and S− for a four-wire connection. A minimum voltage of 1 V is specified for remote compensation, and total output must not exceed 65 W.

Can the NXI-3106 be used in integrated test systems?

Yes. It operates independently or integrates into NXI-F1080, NXI-F1030 and NXI-F1020 chassis. The rearplane, remote control and sequences support system operation.

Is the module suitable for production and end-of-line testing?

Yes. The series is specified for large-scale production-line testing. Channel density, automated setpoints, batch ON/OFF and data recording support recurring test routines.

Technical consultation and project enquiry

To configure the appropriate NXI-3106 system, we need the DUT voltage, current and power range, required channel count, planned sequence routine, and requirements for regulation priority, remote sense, interfaces and chassis. Details of the available 220 V AC infrastructure and environmental conditions help with system planning.

Discuss your NXI-3106 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly