The A modules provide 0.01 mV setting and readback resolution with 0.1 mV accuracy at 23 ±5 °C.
N9000 – Modular Battery Cell Simulator with 0.1 mV Voltage Accuracy
For high-precision AFE, BMS and HIL testing with isolated cell channels, synchronous control and fault simulation.
The N9000 combines a modular 4U measurement and control chassis with electrically isolated, bidirectional battery-cell channels. For the 0.1 mV version described here, configurations from 8 to 36 channels provide 0 to 6 V and either ±1 A or ±5 A per channel.
Each NB101 channel can source and sink current, supporting charging, discharging and balancing scenarios.
Four channels per NB101 module and up to nine pluggable full-slot modules enable application-specific configurations and later expansion.
Gigabit LAN, CAN FD, hardware triggering and synchronization down to 200 µs support time-critical multi-channel and BMS HIL tests.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
N9104-06-01 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9108-06-01 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9112-06-01 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9116-06-01 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9120-06-01 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9124-06-01 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9108-28-01 Bidirectional modular cell simulator, 8 isolated CH à 28 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9132-06-01 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9136-06-01 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±1 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9112-06-05 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9116-06-05 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9120-06-05 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9124-06-05 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9128-06-05 Bidirectional modular cell simulator, 28 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9132-06-05 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9136-06-05 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9108-06-05 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
|
Description
N9104-06-05 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±5 A, 0.1 mV accuracy, series and M/S connectable, 4U
|
Current [A]
5
|
Power [P]
30
|
Voltage [V]
6
|
Technical Data
Design
Standard 19"
Height
4
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
36
32
28
24
20
16
12
8
4
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Bidirectional
Fault Simulation
< 10 Channels
> 10 Channels
Uni-/Bidirectional
Bidirectional
N9000 battery cell simulator overview
The N9000 is a modular platform for simulating battery cells and related BMS signals. A 19-inch, 4U chassis accommodates up to nine full-slot modules and one half-slot module. The model range described here uses only the high-accuracy NB101 A modules for individual cell simulation: each channel operates bidirectionally from 0 to 6 V with either ±1 A or ±5 A. Depending on the installed modules, 8 to 36 electrically isolated channels are available and can be connected in series to reproduce a cell stack. The platform can be expanded with one NB102 module for resistance and temperature simulation or with NB106 high-voltage modules for total-voltage simulation. Local operation, LAN, CAN, synchronous triggering and PC software support both individual measurements and automated multi-channel sequences. Typical applications include BMS HIL systems, AFE IC testing, balancing tests and BMS applications in vehicles and energy-storage systems.
Key benefits
Accurate cell voltages
The NB101 A modules achieve 0.1 mV setting and readback accuracy at 23 ±5 °C with 0.01 mV resolution.
Source and sink current
Bidirectional channels rated up to ±5 A reproduce charging, discharging, active-balancing and passive-balancing states without changing instruments.
High channel density
Up to nine four-channel modules provide 36 battery-cell channels in a 4U chassis and allow application-specific configurations.
Four-wire DUT connection
Separate sense leads measure voltage directly at the DUT and compensate for voltage drops across the output leads.
Fast voltage transitions
Rise times down to 40 µs, fall times down to 100 µs and recovery below 100 µs support dynamic testing.
Synchronized automation
LAN, CAN FD, hardware triggering, command response down to 1 ms and multi-channel synchronization down to 200 µs support HIL and system tests.
How bidirectional cell simulation works
Each NB101 channel provides a programmable cell voltage and can conduct current in both directions. In source operation it supplies the DUT; in sink operation it absorbs current. Input and output current limits can be set separately. A programmable internal resistance from 0 to 1,000 mΩ complements the voltage source to reproduce a cell's electrical behavior in greater detail.
The channels are isolated from one another up to 500 V DC and from ground up to 2,500 V DC. This allows them to be connected in series as a cell stack. Each channel uses a four-wire connection with separate sense leads to maintain accurate voltage at the DUT. A safety interlock dry contact must be closed before voltage or current setpoints can be output.
Models with 0.1 mV accuracy
The following selection includes only N9000 systems using NB101 A battery-simulation modules. Each configuration contains one N9000 chassis; the channel count is determined by two to nine four-channel modules.
| System model | Channels | NB101 module | Voltage | Current | Power |
|---|---|---|---|---|---|
| N9108-06-01 | 8 | 2 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9112-06-01 | 12 | 3 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9116-06-01 | 16 | 4 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9120-06-01 | 20 | 5 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9124-06-01 | 24 | 6 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9128-06-01 | 28 | 7 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9132-06-01 | 32 | 8 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9136-06-01 | 36 | 9 × NB101-06-01-A | 0–6 V/channel | ±1 A/channel | 6 W/channel |
| N9108-06-05 | 8 | 2 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9112-06-05 | 12 | 3 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9116-06-05 | 16 | 4 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9120-06-05 | 20 | 5 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9124-06-05 | 24 | 6 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9128-06-05 | 28 | 7 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9132-06-05 | 32 | 8 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
| N9136-06-05 | 36 | 9 × NB101-06-05-A | 0–6 V/channel | ±5 A/channel | 30 W/channel |
Accuracy, current measurement and dynamics
| Parameter | NB101-06-01-A | NB101-06-05-A | Condition |
|---|---|---|---|
| Voltage range | 0–6 V/channel | 0–6 V/channel | 4 channels per module |
| Voltage setting/readback resolution | 0.01 mV | 0.01 mV | CV operation |
| Voltage setting/readback accuracy | 0.1 mV | 0.1 mV | 23 ±5 °C |
| Main current range | −1 to +1 A | −5 to +5 A | 0.1 mA resolution; 1 mA or 5 mA accuracy |
| µA current range | −1 to +1 mA | −1 to +1 mA | 0.1 µA resolution; 1 µA accuracy at 23 ±5 °C |
| Voltage rise time | ≤40 µs | ≤40 µs | 10–90%, no load or purely resistive full load |
| Voltage fall time | ≤100 µs | ≤100 µs | 90–10%, no load or purely resistive full load |
| Transient recovery time | <100 µs | <100 µs | Purely resistive load, 10–90% change |
| Voltage ripple/noise | ≤2 mV RMS | ≤2 mV RMS | Both A modules |
The accuracy values apply within one year after calibration at 18 to 28 °C and up to 80% relative humidity. A 30-minute warm-up is specified before precision measurements.
Operating modes and programmable test sequences
| Function | Operation | Typical benefit |
|---|---|---|
| Source Mode | Programmable cell voltage, separate input/output current limits and 0–1,000 mΩ internal resistance. | Cell supply, charging, discharging and balancing. |
| Sweep | Voltage changes from start to end value in defined increments and intervals; current limits and end current are configurable. | Repeatable scans and characteristic testing on portable batteries. |
| SEQ | Up to 200 steps with voltage, input/output current limits, internal resistance and dwell time; 1 to 9,999 cycles. | Automated multi-step test profiles. |
| SOC simulation | Up to 200 steps link capacity, open-circuit voltage, current limits and internal resistance; eight files can be stored. | Reproduction of state-of-charge profiles for BMS testing. |
| Fault simulation | Positive/negative open circuit, short circuit and reverse polarity; switching only in Source Mode with no external voltage or current applied. | Repeatable verification of BMS fault detection. |
| Data logging and charts | Voltage, current, power and capacity can be logged; up to four curve sets can be displayed independently. | Documentation and analysis of multi-channel tests. |
Optional temperature and total-voltage modules
Resistance and temperature simulation
The half-slot module provides 12, 24 or 36 channels. Depending on the model, ranges extend to 600 kΩ, 1.11 MΩ, 6 MΩ or 11.11 MΩ with 1 Ω or 10 Ω resolution. The 600 kΩ and 6 MΩ variants support NTC short-circuit and NTC open-circuit simulation.
Programmable total voltage
The NB106-1200 provides 0–1,200 V, 100 mA and 120 W; the NB106-2500 provides 0–2,500 V, 100 mA and 250 W. Both support CV, CC, sweep and sequence operation. NB106 and NB101 use the same full-slot positions.
Typical applications
BMS HIL and cell stacks
Synchronized cell voltages, SOC states, internal resistances and fault conditions provide repeatable input signals for a BMS.
AFE IC testing
0.1 mV voltage accuracy, 0.01 mV resolution and µA current measurement support verification of high-resolution cell-voltage acquisition channels.
Active and passive balancing
Bidirectional channels source or sink current to reproduce different balancing directions for each cell.
BMS temperature acquisition
An optional NB102 simulates NTC characteristics and resistance values for testing temperature-measurement channels.
Total-voltage input
An optional NB106 module complements the simulated cell stack with a programmable high-voltage source up to 1,200 V or 2,500 V.
Vehicle and energy-storage BMS
Cell, fault, temperature and total-voltage simulation support BMS test systems for electric vehicles and stationary energy storage.
Interfaces and automation
| Equipment | Function | Note |
|---|---|---|
| Gigabit LAN | Remote control via TCP or UDP and integration of multiple chassis over a network. | Two LAN ports simplify cascaded systems. |
| CAN 2.0 / CAN FD | Control and cyclic upload of voltage, current and power data. | CAN FD arbitration and data rates are configurable. |
| CAN/TRIG | Inputs and outputs for cascade clock and cascade trigger. | Hardware-based synchronization of multiple instruments. |
| Local operation | 3.2-inch display, function keys, numeric keypad and rotary knob. | Status and parameters directly at the chassis. |
| PC software | Channel configuration, operating modes, charts, data logging and history. | Batch operation of selected channels is supported. |
Installation, chassis and protection
| Feature | Specification |
|---|---|
| Form factor | 4U, 19-inch; 177 × 482 mm including handles × 600 mm (H × W × D); approximately 19 kg. |
| Slots | Nine full-slot positions plus one half-slot position. |
| Chassis AC input | Single-phase 100–240 V AC, 47–63 Hz; ≤9 A at 220 V, ≤18 A at 110 V. |
| Temperature | Operation 0–40 °C; storage −20–60 °C. |
| Environment | Below 2,000 m, 5–90% relative humidity non-condensing, 80–110 kPa. |
| Interlock | Setpoint output is possible only while the dry contact is closed. |
| NB101 protection | Configurable overvoltage, overcurrent and overpower thresholds turn off the affected output when triggered. |
N9000 FAQ
Which accuracy version is described here?
The model and performance data apply exclusively to the 0.1 mV version using NB101-06-01-A or NB101-06-05-A modules.
How many battery-cell channels are available?
The preconfigured 0.1 mV systems cover 8 to 36 channels in four-channel increments.
Can channels be connected in series?
Yes. The channels are isolated and designed for series connection. In series SOC operation, however, internal resistance cannot be set.
How are lead losses compensated?
The four-wire connection measures voltage through S+ and S− directly at the DUT and compensates for voltage drop across the load leads.
Which interfaces are provided?
The chassis supports LAN, CAN 2.0 and CAN FD, plus hardware clock and trigger lines for cascaded systems.
Can multiple chassis be controlled together?
Yes. Multiple instruments can be connected over LAN and synchronized through the cascade clock and trigger signals.
Which expansion modules are available?
The NB102 adds resistance and temperature simulation; the NB106 provides programmable total voltage up to 1,200 V or 2,500 V.
Is the N9000 suitable for BMS HIL testing?
Yes. Synchronized cell channels, SOC profiles, programmable internal resistance and defined fault states support BMS HIL test systems.
Can AFE inputs be tested at high resolution?
Yes. The A modules combine 0.1 mV voltage accuracy with 0.01 mV resolution and a µA range for small channel currents.
Can active and passive balancing be evaluated?
Yes. The bidirectional NB101 channels can source and sink current, reproducing both balancing directions.
Technical consultation and project enquiry
For system sizing, please provide the channel count, cell voltage, current range, accuracy requirement, required fault states, temperature and total-voltage simulation, interfaces and synchronization requirements.