Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N9004-06-01

Description
N9004-06-01 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9004-06-01
N9004-06-01 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9008-06-01

Description
N9008-06-01 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9008-06-01
N9008-06-01 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9012-06-01

Description
N9012-06-01 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9012-06-01
N9012-06-01 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9016-06-01

Description
N9016-06-01 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9016-06-01
N9016-06-01 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9020-06-01

Description
N9020-06-01 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9020-06-01
N9020-06-01 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9024-06-01

Description
N9024-06-01 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9024-06-01
N9024-06-01 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9028-06-01

Description
N9028-06-01 Bidirectional modular cell simulator, 28 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9028-06-01
N9028-06-01 Bidirectional modular cell simulator, 28 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9032-06-01

Description
N9032-06-01 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9032-06-01
N9032-06-01 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9036-06-01

Description
N9036-06-01 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
1
Power [P]
6
Voltage [V]
6
N9036-06-01
N9036-06-01 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±1 A, 0.5 mV accuracy, series and M/S connectable, 4U
1
6
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9012-06-05

Description
N9012-06-05 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9012-06-05
N9012-06-05 Bidirectional modular cell simulator, 12 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9016-06-05

Description
N9016-06-05 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9016-06-05
N9016-06-05 Bidirectional modular cell simulator, 16 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9020-06-05

Description
N9020-06-05 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9020-06-05
N9020-06-05 Bidirectional modular cell simulator, 20 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9024-06-05

Description
N9024-06-05 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9024-06-05
N9024-06-05 Bidirectional modular cell simulator, 24 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9028-06-05

Description
N9028-06-05 Bidirectional modular cell simulator, 28 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9028-06-05
N9028-06-05 Bidirectional modular cell simulator, 28 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9032-06-05

Description
N9032-06-05 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9032-06-05
N9032-06-05 Bidirectional modular cell simulator, 32 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9036-06-05

Description
N9036-06-05 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9036-06-05
N9036-06-05 Bidirectional modular cell simulator, 36 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9004-06-05

Description
N9004-06-05 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9004-06-05
N9004-06-05 Bidirectional modular cell simulator, 4 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9008-06-05

Description
N9008-06-05 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
Current [A]
5
Power [P]
30
Voltage [V]
6
N9008-06-05
N9008-06-05 Bidirectional modular cell simulator, 8 isolated CH à 6 V/±5 A, 0.5 mV accuracy, series and M/S connectable, 4U
5
30
6
Modular system

Technical Data

Design

Standard 19"

Height

4

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

36

32

28

24

20

16

12

8

4

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

< 10 Channels

> 10 Channels

Uni-/Bidirectional

Bidirectional

N9000 battery cell simulator overview

The N9000 is a modular two-quadrant platform for multichannel BMS and cell testing. Its 19-inch, 4U chassis accommodates up to nine full-width plug-in modules plus one additional half-width module. For the selected 0.5 mV version, only the NB101-06-01-B and NB101-06-05-B battery cell simulation modules are included. Each provides four electrically isolated channels from 0 to 6 V; depending on the module, ratings are ±1 A and 6 W or ±5 A and 30 W per channel. Complete models cover 8 to 36 cell channels. An NB102 resistance module for temperature or NTC simulation and an NB106 high-voltage module for total-voltage simulation can be added. Local operation, LAN, CAN, hardware triggering and cascading support stand-alone test stations and synchronized HIL systems.

Key benefits

Precise cell voltages

0.1 mV setting and readback resolution with 0.5 mV accuracy at 23 ±5 °C supports demanding BMS and AFE tests.

Bidirectional cell channel

Each channel can source and sink current, while the additional µA range captures small balancing and quiescent currents.

Synchronized multichannel tests

Hardware triggering and a high-speed clock coordinate multiple modules with channel synchronization from 200 µs.

Configuration by channel count

Four-channel battery modules, one half-width resistance module and optional high-voltage modules adapt the platform to the test setup.

Faults per cell channel

Short circuit, positive or negative terminal open circuit and polarity reversal create defined cell faults for BMS response testing.

Four-wire connection

Separate sense leads measure voltage directly at the DUT and compensate for voltage drop along the connection leads.

How the modular battery simulation works

The NB101 B modules regulate a positive cell voltage from 0 to 6 V on each channel. Their bidirectional current path lets a channel power the DUT or absorb current from it. Separate input and output current limits and a programmable internal resistance from 0 to 1,000 mΩ reproduce different cell states. Electrically isolated channels can be connected in series to form a cell stack.

For a complete BMS test setup, the chassis can combine cell and fault simulation with an NB102 module for resistance or NTC emulation and an NB106 module for total voltage. NB101 and NB106 each occupy one full slot; NB102 occupies the half-width slot. The available combination therefore depends on the required number of cell channels.

Models with 0.5 mV accuracy

Every complete model listed below contains one N9000 chassis and exclusively NB101 B battery simulation modules with 0.5 mV voltage accuracy.

Complete modelCell channelsRange per channelBattery moduleModule quantity
N9008-06-0180–6 V / ±1 A / 6 WNB101-06-01-B2
N9012-06-01120–6 V / ±1 A / 6 WNB101-06-01-B3
N9016-06-01160–6 V / ±1 A / 6 WNB101-06-01-B4
N9020-06-01200–6 V / ±1 A / 6 WNB101-06-01-B5
N9024-06-01240–6 V / ±1 A / 6 WNB101-06-01-B6
N9028-06-01280–6 V / ±1 A / 6 WNB101-06-01-B7
N9032-06-01320–6 V / ±1 A / 6 WNB101-06-01-B8
N9036-06-01360–6 V / ±1 A / 6 WNB101-06-01-B9
N9008-06-0580–6 V / ±5 A / 30 WNB101-06-05-B2
N9012-06-05120–6 V / ±5 A / 30 WNB101-06-05-B3
N9016-06-05160–6 V / ±5 A / 30 WNB101-06-05-B4
N9020-06-05200–6 V / ±5 A / 30 WNB101-06-05-B5
N9024-06-05240–6 V / ±5 A / 30 WNB101-06-05-B6
N9028-06-05280–6 V / ±5 A / 30 WNB101-06-05-B7
N9032-06-05320–6 V / ±5 A / 30 WNB101-06-05-B8
N9036-06-05360–6 V / ±5 A / 30 WNB101-06-05-B9

Modules and key specifications

ModuleChannelsRangeClassification
NB101-06-01-B40–6 V; ±1 A; 6 W per channel0.5 mV voltage accuracy; 0.1 mV setting and readback resolution
NB101-06-05-B40–6 V; ±5 A; 30 W per channel0.5 mV voltage accuracy; 0.1 mV setting and readback resolution
NB102 series12 / 24 / 36600 kΩ, 1.11 MΩ, 6 MΩ or 11.11 MΩ full scaleResistance and NTC simulation; one NB102 module per chassis
NB106-120010–1,200 V; 0–100 mA; 120 WProgrammable total-voltage source; CV, CC, sweep and sequence
NB106-250010–2,500 V; 0–100 mA; 250 WProgrammable total-voltage source; CV, CC, sweep and sequence

Configuration note: NB101 and NB106 use the same full-width slots. The chassis provides nine full-width slots and one additional half-width slot, so the cell-channel count and auxiliary modules must be planned together.

Dynamics, resolution and isolation of NB101 B modules

CharacteristicValueCondition
Voltage accuracy0.5 mVSetting and readback at 23 ±5 °C
Voltage resolution0.1 mVSetting and readback
Current resolution in low range0.1 µAMeasurement and setting range −1 to +1 mA
Voltage rise time≤40 µs10–90%, no load or purely resistive full load
Voltage fall time≤100 µs90–10%, no load or purely resistive full load
Transient recovery time<100 µsPurely resistive load, 10–90% change
Isolation500 V DC channel to channel; 2,500 V DC output to groundNB101 B module

Operating modes and programmable functions

FunctionOperationBenefit
Source modeProgrammable cell voltage, input and output current limits, and 0–1,000 mΩ internal resistanceReproduce cell states, charging, discharging, and active or passive balancing
SweepVoltage ramp with start, increment, end, time interval, and current cutoff valuesRun repeatable scans and charge or discharge transitions
SEQUp to 200 steps with voltage, current limits, internal resistance, and dwell time; CSV import and exportRepeat and document multistep test procedures
SOCUp to 200 steps and eight profiles with capacity, open-circuit voltage, current limits, and internal resistanceSimulate cell parameters as a function of state of charge
Fault simulationShort circuit, positive or negative open circuit, and polarity reversal in source modeTest BMS fault detection and response in a controlled manner
Chart and data loggingDisplay up to four curves; log channel values to a file and retrieve history dataObserve multichannel trends and analyze them later

Typical applications

BMS HIL testing

Fast synchronized cell voltages, fault states, temperature values, and total voltage emulate the electrical BMS inputs in real time.

AFE and measurement-chain testing

0.1 mV resolution and 0.5 mV accuracy provide defined cell voltages for checking acquisition channels and measurement deviations.

Balancing and quiescent current

Bidirectional channels and the µA range capture charging, discharging, and small equalization currents in active and passive balancing methods.

BMS for automotive and e-mobility

Cell stacks, temperature sensors, total voltage, and electrical faults can be simulated for electric vehicles and electric two- or three-wheelers.

Energy-storage BMS

Cell and NTC simulation supports testing of voltage and temperature acquisition in stationary energy-storage systems.

Base-station power BMS

Programmable cell states, sequences, and fault cases reproduce power-supply scenarios for battery management systems in base stations.

Interfaces, software and scaling

EquipmentImplementationFunction
LANRJ45; TCP or UDPPC remote control, system integration, and multi-unit operation
CANCAN 2.0 and CAN FD; NB106 supports CAN 2.0 onlyControl, active measurement upload, and test-system connection
SYNC / TRIGSeparate clock and trigger linesSynchronized procedures between chassis in high-speed mode
PC softwareChannel configuration, function profiles, charts, and data loggingConfigure and monitor multiple channels and manage recorded data
CascadingOne master and up to 15 slavesControl and read channels from several N9000 units centrally through the master

High-speed mode: The master and slaves are connected through Ethernet, with clock and trigger lines daisy-chained separately. In this mode, the battery modules operate in source mode only.

Installation and protection functions

CharacteristicSpecificationNote
Form factor177 × 482 × 600 mm including handles; approx. 19 kg4U, 19-inch rack installation with optional rail kit
AC inputSingle-phase 100–240 V AC; 47–63 HzUp to 9 A at 220 V or 18 A at 110 V
Environment0–40 °C; 5–90% RH, non-condensing; altitude <2,000 mStorage temperature −20 to 60 °C
InterlockDry-contact bridgeOutputs can be enabled only while the contact is closed
Protection limitsOvervoltage, overcurrent, and overpowerA trigger switches off the affected output and displays its status
OFF stateNormal or high impedanceHigh-impedance mode opens internal relays and adds approximately 300 ms to turn-on

N9000 FAQ

Which battery modules are included here?

Only NB101-06-01-B and NB101-06-05-B with 0.5 mV voltage accuracy. The 0.1 mV A versions are not part of this module selection.

How many cell channels fit in one chassis?

The standard 0.5 mV complete models provide 8 to 36 channels in four-channel increments. Auxiliary modules occupy separate slots and may reduce the available cell-channel count.

Can the channels be connected in series?

Yes. The channels are electrically isolated and can be connected in series as a cell stack, provided the channel and isolation limits are observed.

Which faults can be simulated?

Each channel supports short circuit, positive or negative terminal open circuit, and polarity reversal. Fault switching is permitted in source mode only.

How are lead losses compensated?

The four-wire connection routes separate sense leads to the DUT, measuring voltage directly at its terminals.

Can several chassis operate synchronously?

Yes. One master can coordinate up to 15 slaves; Ethernet and separate clock and trigger lines connect the units in high-speed mode.

Is the N9000 suitable for BMS HIL tests?

Yes. Multichannel synchronization, bidirectional cell channels, and fault, temperature, and total-voltage simulation reproduce the main electrical BMS interfaces.

Can the N9000 test AFE measurement channels?

Yes. The 0.5 mV modules provide cell voltages with 0.1 mV resolution, creating defined test points for AFE and BMS measurement chains.

Can temperature sensors be simulated?

Yes, with one NB102 module. It emulates resistance or NTC values on 12, 24, or 36 channels; the required version is selected separately.

Technical consultation and project enquiry

To configure the system, we need the number of cell channels, the ±1 A or ±5 A current range, and requirements for temperature, total-voltage, and fault simulation. Please also specify HIL synchronization, interfaces, cascading, rack installation, and the safety concept.

Discuss your N9000 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly