Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N83624-06-01

Description
N83624-06-01 High-accuracy 24-channel battery simulator, 6 V/channel, 1 A/channel, 6 W/channel, 3U
Current [A]
1
Power [P]
6
Voltage [V]
6
N83624-06-01
N83624-06-01 High-accuracy 24-channel battery simulator, 6 V/channel, 1 A/channel, 6 W/channel, 3U
1
6
6
16 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Unidirectional

N83624-06-03

Description
N83624-06-03 High-accuracy 24-channel battery simulator, 6 V/channel, 3 A/channel, 18 W/channel, 3U
Current [A]
3
Power [P]
18
Voltage [V]
6
N83624-06-03
N83624-06-03 High-accuracy 24-channel battery simulator, 6 V/channel, 3 A/channel, 18 W/channel, 3U
3
18
6
16 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Unidirectional

N83624-06-05

Description
N83624-06-05 High-accuracy 24-channel battery simulator, 6 V/channel, 5 A/channel, 30 W/channel, 3U
Current [A]
5
Power [P]
30
Voltage [V]
6
N83624-06-05
N83624-06-05 High-accuracy 24-channel battery simulator, 6 V/channel, 5 A/channel, 30 W/channel, 3U
5
30
6
16 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Unidirectional

N83624-15-01

Description
N83624-15-01 High-accuracy 24-channel battery simulator, 15 V/channel, 1 A/channel, 15 W/channel, 3U
Current [A]
1
Power [P]
15
Voltage [V]
15
N83624-15-01
N83624-15-01 High-accuracy 24-channel battery simulator, 15 V/channel, 1 A/channel, 15 W/channel, 3U
1
15
15
16 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Unidirectional

N83624 battery cell simulator overview

The N83624 series is a programmable multi-channel battery cell simulator for precise BMS, CMS and automated test applications. A 19-inch 3U chassis provides 24 channels that are isolated from each other. The four models combine 6 V or 15 V with 1 A, 3 A or 5 A and up to 30 W per channel. Each channel can be set, measured and switched separately; series connection enables multi-cell systems to be reproduced. In addition to CV source operation, the series supports charge/discharge simulation, SOC profiles and programmable sequences. Operation and monitoring are available locally through the 4.3-inch colour display or remotely through LAN, RS232 and CAN. Application software adds per-channel parameter setting, graph display, data analysis and reporting functions. The NB108-2 fault simulation unit is available as an option for defined wiring faults.

Key benefits

High channel density

Twenty-four independent channels in 3U reduce the rack space required for multi-cell BMS and CMS test systems.

Precise cell voltage

The 6 V models achieve 0.6 mV setting and readback accuracy at 23 ±5 °C.

Measure low currents

The 0–1 mA range provides 0.1 µA setting and readback resolution for small channel currents.

Fast voltage rise

For the 6 V models, the 10–90% rise time is below 20 µs at no load and full load.

Repeatable profiles

SOC and SEQ files each store up to 200 steps for recurring cell states and voltage profiles.

Optional fault states

The extension simulates short circuit, positive- or negative-line interruption and reverse polarity in source mode.

Battery cell simulation operating principle

In Source mode, each channel operates as a constant-voltage source with an adjustable current limit. High, low and automatically switching ranges are available for current readback. Four-wire connection and remote sense compensate for voltage drop in the connecting leads; the specified remote compensation voltage is up to 1 V.

Charge mode reproduces battery charging and discharging using a voltage setpoint, current limit and simulated internal resistance. In SOC mode, capacity, open-circuit voltage and internal resistance are linked step by step to reproduce the electrical change in state of charge. SEQ mode instead executes freely defined voltage, current-limit, resistance and timing values in a programmed order. The isolated channels can be switched individually or together and connected in series for multi-cell DUTs.

Models and ratings per channel

ModelVoltage per channelCurrent per channelPower per channelChannels
N83624-06-010–6 V0–1 A6 W24
N83624-06-030–6 V0–3 A18 W24
N83624-06-050–6 V0–5 A30 W24
N83624-15-010–15 V0–1 A15 W24

Model selection: Voltage, current and power ratings apply per channel. A cell-stack setup must also consider channel count, the required series connection, measurement range and required fault states.

Accuracy and dynamic response

Characteristic6 V models15 V modelCondition
Voltage setting / readback resolution0.1 mV0.1 mVCV mode
Voltage setting / readback accuracy0.6 mV1.5 mV23 ±5 °C
Voltage ripple≤2 mV rms≤5 mV rms20 Hz–20 MHz
Current resolution in the 0–1 mA range0.1 µA0.1 µASetting and readback
Voltage rise, no load / full load<20 µs<40 µs10–90% of final value
Voltage fall, no load / full load<3 ms / <100 µs<6 ms / <200 µs90–10% of final value
Transient voltage drop200 mV400 mV10–90% load step at full output voltage
Transient recovery time<100 µs<200 µsRecovery to 50 mV below the previous value

A 30-minute warm-up is specified for accuracy measurements, and the specification applies within one year after calibration. In the high current range, setting and readback resolution are 0.1 mA. The corresponding accuracy is 1 mA for the 1 A models, 3 mA for the 3 A model and 5 mA for the 5 A model.

Operating modes and programmable functions

FunctionParametersBenefit in the test routine
SourceCV setpoint, current limit and current readback range per channelStable cell-voltage supply for each channel with a defined current limit
ChargeVoltage, current limit and 0–99,999.9 mΩ simulated internal resistanceElectrical reproduction of charging and discharging
SOC Edit / SOC Test8 files with up to 200 steps each for capacity, voltage, current limit and internal resistanceRepeatable changes in open-circuit voltage and internal resistance across state of charge
SEQ Edit / SEQ Test10 files with up to 200 steps each; 0–99.999 s dwell time plus file and step cyclesAutomated voltage profiles and repeated sequences of test steps
GraphVoltage traces for four selectable channels simultaneouslyLocal observation of changes over time
All ViewVoltage, current, power and on/off state of every channelQuick overview of a multi-channel test setup

Typical applications

BMS and CMS for energy storage

SOC files link capacity, open-circuit voltage and internal resistance to provide repeatable states in the storage system.

Calibration of voltage acquisition

The finely adjustable channels provide reference voltages for multi-channel acquisition units such as fuel-cell voltage monitors.

Interfaces, software and automation

EquipmentAvailabilityFunction
Two LAN portsStandardTCP or UDP communication and simplified cascading of multiple instruments
RS232StandardRemote control at 9,600, 19,200, 38,400, 57,600 or 115,200 baud
CANStandardChannel addressing and cyclical transmission of voltage, current and power
4.3-inch colour displayStandardLocal parameter setting, channel overview and graph display
N83624 application softwareStandardVoltage and current setting per channel plus graphs, data analysis and reporting functions
NB108-2OptionalRelay-based simulation of short circuit, line interruption and reverse polarity
Leakage-current measurement moduleOptionalMeasurement of leakage currents in the nA range

Channel coupling and system configuration

The 24 channels are isolated from each other and can be connected in series for a higher total voltage. Isolation between channels is specified as 500 V DC. Total voltage, channel count, wiring and potential to ground must be designed for the specific DUT while observing the model limits.

Two LAN ports and unique IP addresses support remote control of multiple instruments. For CAN, channel addresses are derived in blocks from the instrument ID. In a series connection spanning multiple instruments, every channel must be off before the AC mains supply is disconnected.

Installation and operating conditions

CharacteristicConfiguration / condition
Form factor19-inch, 3U; 132.5 × 482.0 × 559.0 mm without the optional extension
WeightApprox. 17 kg without the optional extension
AC inputSingle-phase 100–240 V AC, 47–63 Hz; observe the rear-panel voltage marking
Input current≤8 A at 220 V; ≤14 A at 110 V
Operating temperature0–40 °C
Storage temperature−20 to +60 °C
EnvironmentAltitude <2,000 m; 5–90% RH, non-condensing; 80–110 kPa
CoolingAir cooling; keep inlet and outlet openings clear

Protection and fault functions

Overvoltage, overcurrent and overpower protection can be set for each channel. When OVP, OCP or OPP trips, the output is shut down immediately and the corresponding status is displayed. OCP limits output or input current, while OPP limits output power.

With the optional NB108-2 unit, the instrument can simulate short circuit, interruption of the negative line, interruption of the positive line and reverse polarity. This function is available only in Source mode. The fault state must be selected while the channel is off; the channel is then switched on. Instrument protection and fault simulation must be incorporated into the safety design of the complete test system.

N83624 FAQ

How do I select the right model?

The decisive values are maximum cell voltage, required channel current and power per channel. The 6 V models provide 1, 3 or 5 A; the 15 V model provides 1 A.

Can the channels be connected in series?

Yes. The 24 channels are mutually isolated and intended for series connection. The configuration must consider the model limits and 500 V DC isolation between channels.

Which accuracy conditions apply?

Setting and readback accuracy are specified at 23 ±5 °C. Accuracy measurements require a 30-minute warm-up and apply within one year after calibration.

Can the instrument be operated locally and remotely?

Yes. The 4.3-inch colour display provides local operation. LAN, RS232 and CAN are available for integration into automated systems.

Is fault simulation included?

No. The NB108-2 unit is optional. It simulates short circuit, positive- or negative-line interruption and reverse polarity in Source mode only.

Is the N83624 suitable for BMS and CMS testing in electric vehicles and energy storage systems?

Yes. The series is intended for these applications and reproduces cell voltages, SOC states and, optionally, defined wiring faults through isolated channels.

Can the N83624 be used for UAV battery management systems?

Yes. UAV BMS/CMS testing is a specified application. The series simulates multiple cell channels; this does not imply an aviation certification.

Does the series support R&D and production testing of portable electronics?

Yes. Mobile devices, Bluetooth earphones and smartwatches are specified applications. Twenty-four channels, sequences and remote control support repeatable multi-channel tests.

Technical consultation and project enquiry

To configure an N83624 system, specify cell voltage, channel current, channel count and series connection, together with the required measurement ranges. Please also include SOC or sequence profiles, interfaces, dynamic requirements and requested fault states.

Discuss your N83624 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly