Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N83524-06-01

Description
N83524-06-01 Bidirectional 24-channel battery simulator, 6 V/channel, ±1 A/channel, 6 W/channel, 3U
Current [A]
1
Power [P]
6
Voltage [V]
6
N83524-06-01
N83524-06-01 Bidirectional 24-channel battery simulator, 6 V/channel, ±1 A/channel, 6 W/channel, 3U
1
6
6
24 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Bidirectional

N83524-06-03

Description
N83524-06-03 Bidirectional 24-channel battery simulator, 6 V/channel, ±3 A/channel, 18 W/channel, 3U
Current [A]
3
Power [P]
18
Voltage [V]
6
N83524-06-03
N83524-06-03 Bidirectional 24-channel battery simulator, 6 V/channel, ±3 A/channel, 18 W/channel, 3U
3
18
6
24 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Bidirectional

N83524-06-05

Description
N83524-06-05 Bidirectional 24-channel battery simulator, 6 V/channel, ±5 A/channel, 30 W/channel, 3U
Current [A]
5
Power [P]
30
Voltage [V]
6
N83524-06-05
N83524-06-05 Bidirectional 24-channel battery simulator, 6 V/channel, ±5 A/channel, 30 W/channel, 3U
5
30
6
24 Channel Simulator

Technical Data

Design

Standard 19"

Height

3

Interfaces / Protocols

max. current per channel

max. power per channel

max. voltage per channel

Number of channels

24

Product category

Battery Cell Simulators

Type of Batterycellsimulator

Bidirectional

Fault Simulation

> 10 Channels

Uni-/Bidirectional

Bidirectional

N83524 battery cell simulator overview

The N83524 series is a programmable bidirectional multi-channel battery simulator for BMS, CMS and automated electronics testing. The 19-inch instrument integrates 24 mutually isolated channels in a 3U chassis. Each channel can source and sink current, enabling charge, discharge and active or passive balancing conditions to be examined without real cell stacks. The three models operate from 0–6 V per channel with rated currents of ±1 A, ±3 A or ±5 A. In addition to Source and Charge operation, Battery, SOC and SEQ functions provide repeatable profiles. A 4.3-inch color display supports local control, while LAN, RS232 and CAN interfaces allow integration into automated test systems. Remote sense compensates for wiring losses at the device under test. The optional NB108-2 fault-simulation unit adds defined open-circuit, short-circuit and reverse-polarity conditions.

Key benefits

High channel density

Twenty-four independent channels in 3U reduce instrument count and rack space for multi-cell BMS testing.

Source and sink

Bidirectional current flow up to ±5 A per channel reproduces charge, discharge and balancing currents.

Accurate cell voltage

0.6 mV setting and readback accuracy at 23 ±5 °C supports finely stepped cell-voltage testing.

Fast recovery

After a 10-to-90% load step at full output voltage, recovery to within 50 mV of the previous voltage takes less than 100 µs.

Low-current range

The additional ±1 mA measurement range with 0.1 µA resolution helps capture low quiescent and standby currents.

Repeatable profiles

Up to 200 steps per SOC or SEQ file reproduce defined voltage, current, resistance and timing profiles.

How the bidirectional battery simulator works

In Source mode, each channel regulates a constant voltage with separate limits for incoming and outgoing current. Charge mode reproduces charging and discharging with programmable voltage, current limits and simulated internal resistance. Battery mode generates a time-stepped voltage profile between start and end values while applying current limits, internal resistance and an optional current-based stop condition.

SOC profiles combine capacity, open-circuit voltage, current limits and internal resistance into a battery model. SEQ profiles execute freely defined steps containing voltage, current limits, resistance, dwell time, repetitions and linked step ranges. The channels are galvanically isolated from one another and can therefore be connected in series for a cell stack; the specified isolation and terminal limits must be observed.

Models and output range

ModelVoltage per channelCurrent per channelPower per channelChannels
N83524-06-010–6 V±1 A6 W24
N83524-06-030–6 V±3 A18 W24
N83524-06-050–6 V±5 A30 W24

Observe the operating point: Voltage, current and power ratings apply per channel. Usable current is limited by the rated current and maximum channel power of the selected model.

Accuracy and dynamic behavior

ParameterValueCondition or classification
Voltage setting0.1 mV resolution; 0.6 mV accuracyAccuracy at 23 ±5 °C
Voltage readback0.1 mV resolution; 0.6 mV accuracyAccuracy at 23 ±5 °C
Current, main range0.1 mA resolution; 1 mA / 3 mA / 5 mA accuracyModel-dependent at 23 ±5 °C
Current, low range0.1 µA resolution; 1 µA accuracy±1 mA range at 23 ±5 °C
Voltage ripple≤2 mV RMS20 Hz to 20 MHz measurement bandwidth
Rise time<40 µs10–90% of full-scale variation, no load and purely resistive full load
Fall time<100 µs90–10% of full-scale variation, no load and purely resistive full load
Transient recovery<100 µs10-to-90% load step at full output voltage; recovery to within 50 mV of the previous voltage
Remote-sense compensation≤1 VFour-wire connection compensates for lead voltage drop

Operating modes and programmable functions

FunctionOperationTypical purpose
SourceConstant voltage with separate limits for incoming and outgoing currentDefined cell supply and DUT current absorption
ChargeCharge/discharge simulation with voltage, current limits and programmable internal resistanceTesting bidirectional current paths
BatteryVoltage ramp with start, increment and end values, time interval and current-based stop conditionRepeatable battery-state variation
SOC Edit / TestUp to 8 files with up to 200 capacity, voltage, current and resistance points eachSimulation of capacity-dependent open-circuit voltage and internal resistance
SEQ Edit / TestUp to 10 files with up to 200 steps, dwell times, cycles and linked step ranges eachAutomated multi-point and endurance profiles
Graph / All ViewPlots for up to four channels and an overview of all channel valuesFast local inspection of voltage, current, power and status
Fault, optionalShort circuit, positive or negative lead open circuit and reverse polarity via NB108-2Defined fault conditions in Source mode

Typical applications

BMS and CMS testing

Twenty-four isolated bidirectional cell channels reproduce cell voltages and active or passive balancing currents in vehicle and energy-storage systems.

Battery protection boards

Programmable cell voltages, current limits and optional fault conditions support functional testing of battery protection circuits.

Portable electronics and ATE

Fine current measurement and automated profiles support development and production of mobile devices, Bluetooth earphones and smartwatches.

Electric tools

Bidirectional channels simulate battery cells for repeatable manufacturing and functional tests of battery-powered tools.

DC/DC and wireless charging

The channels supply low-power DC/DC converters and wireless-charging products with defined voltage and current limits.

UAV battery management

Multi-channel cell, SOC and balancing profiles support BMS and CMS development and testing for unmanned aerial vehicles.

Interfaces, operation and system integration

EquipmentImplementationFunction
LANTwo Ethernet ports; UDP or TCP selectableRemote control and communication cascading for multiple instruments
RS232DB9; 9,600 to 115,200 baudSerial remote control in existing test systems
CANCAN bus with configurable address and baud rateDirect communication and cyclic transmission of voltage, current and power
Local operation4.3-inch color display, keys and rotary controlParameter entry, channel overview and graph display at the instrument
Application softwareStandard remote-control softwareOperation in multi-channel, multi-parameter test environments
Remote senseFour-wire connection per channelCompensation for voltage drop along the connection leads

Construction, scaling and operating environment

The 24 channels are isolated from one another and can be connected in series to form a cell stack. Two LAN ports simplify communication chaining when multiple N83524 instruments are controlled by one computer. The specified limits continue to apply per instrument and per channel; when instruments are used in series, all channels must be off before mains power is disconnected.

CharacteristicSpecification
Form factor19-inch, 3U
Dimensions, base instrument132.5 × 482.0 × 559.0 mm (H × W × D, including handles)
AC inputSingle-phase, 100–240 V AC, 47–63 Hz
Operating temperature0–40 °C
Storage temperature−20–60 °C
EnvironmentBelow 2,000 m; 5–90% RH, non-condensing

Protection and fault-simulation functions

Overvoltage protection

When the programmed OVP value is reached, the output switches off and the status is indicated.

Overcurrent protection

OCP limits permissible input and output current and switches the affected output off when triggered.

Overpower protection

OPP monitors output power and switches the output off when the programmed protection value is exceeded.

Optional fault simulation: The NB108-2 can simulate short circuit, positive or negative lead interruption and reverse polarity. This function is available only in Source mode; select the fault while the channel is off, then enable the channel.

Channels are isolated by 500 V DC from one another and by 1,500 V DC from ground. These figures describe electrical isolation and do not replace an application-specific safety assessment of the complete test setup.

N83524 series FAQ

How do the three models differ?

All variants provide 24 channels at 0–6 V. Rated current and channel power are ±1 A and 6 W, ±3 A and 18 W, or ±5 A and 30 W.

Are the 24 channels independent?

Yes. The channels are isolated from one another, individually programmable and suitable for series connection in multi-cell devices under test.

How are battery profiles created?

SOC files combine capacity, cell voltage, internal resistance and current limits. Each file can contain up to 200 steps.

Which control interfaces are available?

Two LAN ports, RS232 and CAN are provided for remote control. The display, keys and rotary control support local operation.

Can the N83524 simulate fault conditions?

With the optional NB108-2 unit, short circuit, lead interruption and reverse polarity can be simulated in Source mode.

Can it be used for active and passive balancing tests?

Yes. Every channel can source and sink current, with up to ±5 A per channel depending on the model.

Can portable electronics be tested in ATE systems?

Yes. Programmable cell voltage, low-current measurement and sequence functions support development and production of small battery-powered devices.

Is the N83524 intended for UAV battery management?

Yes. Multi-channel cell, SOC and balancing tests support BMS and CMS development and testing for unmanned aerial vehicles.

Technical consultation and project enquiry

Selecting the appropriate N83524 variant depends on channel current, cell-voltage range, required measurement resolution, SOC/SEQ profiles, control interfaces and possible fault simulation. ET System can assist with instrument configuration, channel interconnection and test-system integration.

Discuss your N83524 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly