One 19-inch instrument provides 16 or 24 mutually isolated test channels, depending on the model.
N8330 – Precision Battery Cell Simulator with up to 24 Channels
For BMS, CMS and chip testing with galvanically isolated cell channels and fine-resolution voltage programming.
The N8330 Series is a programmable multi-channel battery simulator for precise cell-voltage and supply tasks. Up to 24 isolated channels in a 2U chassis, voltage accuracy of 0.001% + 0.1 mV and four-wire sensing support compact, repeatable test setups.
10 µV resolution and 0.001% + 0.1 mV accuracy support demanding cell-level tests.
Voltage rise time is no more than 5 ms; recovery after the specified load change is within 200 µs.
LAN, isolated RS485 and application software enable batch operation, graph display, analysis and report generation.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
N8330A Ultra-high accuracy 24-channel battery simulator, 6 V/channel, 1 A/channel, 6 W/channel, 2U
|
Current [A]
1
|
Power [P]
6
|
Voltage [V]
6
|
Technical Data
Height
2
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
24
16
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Without Display
> 10 Channels
Uni-/Bidirectional
Unidirectional
|
Description
N8330B Ultra-high accuracy 16-channel battery simulator, 5 V/channel, 2 A/channel, 10 W/channel, 2U
|
Current [A]
2
|
Power [P]
10
|
Voltage [V]
5
|
Technical Data
Height
2
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
24
16
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Without Display
> 10 Channels
Uni-/Bidirectional
Unidirectional
|
Description
N8330C Ultra-high accuracy 16-channel battery simulator, 5 V/channel, 3 A/channel, 15 W/channel, 2U
|
Current [A]
3
|
Power [P]
15
|
Voltage [V]
5
|
Technical Data
Height
2
Interfaces / Protocols
max. current per channel
max. power per channel
max. voltage per channel
Number of channels
24
16
Product category
Battery Cell Simulators
Type of Batterycellsimulator
Without Display
> 10 Channels
Uni-/Bidirectional
Unidirectional
N8330 battery simulator overview
The N8330 Series combines a programmable DC source for emulating individual cell voltages with high channel density and precise voltage control. The N8330A provides 24 channels rated at 0–6 V and 0–1 A each. The N8330B and N8330C each provide 16 channels rated at 0–5 V and 0–2 A or 0–3 A respectively. Every channel is isolated and can be set independently; multiple instruments can be connected in series for larger battery stacks. Four-wire sensing measures voltage directly at the DUT and reduces the influence of lead resistance. The 19-inch, 2U design is suited to test systems with many parallel stations. The associated application software supports multi-channel batch operation, graphical data display, analysis and reporting. LAN and isolated RS485 connect the battery simulator to automated test environments.
Key benefits
High channel density in 2U
Up to 24 channels in one 19-inch instrument reduce rack space and instrument count for parallel test tasks.
Precise cell voltages
10 µV resolution and 0.001% + 0.1 mV accuracy enable finely graduated setpoints and readback values.
Isolated channels
500 V DC inter-channel isolation facilitates multi-cell simulations and separate test stations.
Four-wire sensing at the DUT
Separate sense leads measure voltage at the connection point and compensate for voltage drop in the load leads.
Low ripple
Voltage ripple of no more than 2 mV RMS supports the emulation of a stable DC cell voltage.
Software-based multi-channel operation
Batch operation, graph display, data analysis and reporting simplify the evaluation of complex multi-channel tests.
Multi-channel battery simulation principle
Each output channel operates as an independently programmable DC source with constant-voltage and constant-current control. Voltage and the current limit are set and read back per channel. This provides defined cell voltages while limiting current within the range of the selected model.
Each channel is isolated from the other channels. Multiple N8330 instruments can be connected in series for larger battery stacks. The application software provides remote control and supports automated multi-channel testing.
Models and electrical ranges
| Model | Channels | Voltage per channel | Current per channel | Power per channel |
|---|---|---|---|---|
| N8330A | 24 | 0–6 V | 0–1 A | 6 W |
| N8330B | 16 | 0–5 V | 0–2 A | 10 W |
| N8330C | 16 | 0–5 V | 0–3 A | 15 W |
Selection note: Channel count, maximum cell voltage, current limit and power apply per channel. Every operating point must remain within the model's voltage, current and power ratings at the same time.
Accuracy and dynamic behaviour
| Parameter | Specification | Condition |
|---|---|---|
| Voltage setting accuracy | 0.001% + 0.1 mV | 23 ± 5 °C |
| Voltage readback accuracy | 0.001% + 0.1 mV | 23 ± 5 °C |
| Setting and readback resolution | 0.01 mV | All models |
| Voltage ripple | ≤ 2 mV RMS | 20 Hz–20 MHz |
| Voltage rise time | ≤ 5 ms | No load and full load, 10–90% of final value |
| Voltage fall time at full load | N8330A: ≤ 30 ms; N8330B: ≤ 20 ms; N8330C: ≤ 10 ms | 90–10% of final value |
| Transient recovery time | ≤ 200 µs | 10 to 90% load change at full output voltage; recovery to within ± 50 mV |
| Communication response time | ≤ 10 ms | Instrument interface |
Four-wire sensing separates the current path from voltage measurement. This measures voltage at the DUT and largely removes the voltage drop across the connecting leads from the control result.
Typical applications
BMS and CMS testing
Isolated channels emulate individual cell voltages for battery and cell management systems in vehicles and energy storage systems.
UAV and drone electronics
Multi-channel cell voltages support the development and testing of the associated BMS and CMS electronics.
Portable electronics in R&D and production
Mobile phones, Bluetooth earphones and smartwatches can be supplied with repeatable DC voltages at multiple test stations.
Calibration of voltage acquisition devices
Precisely programmable cell voltages provide a reference for voltage acquisition devices such as fuel-cell voltage monitors.
Interfaces, software and automation
| Equipment | Availability | Function |
|---|---|---|
| LAN | Instrument interface | Remote control and integration into network-based test environments |
| RS485 | Isolated instrument interface | Communication with the battery simulator and integration into automated systems |
| N8330 application software | Software support | Channel settings, multi-channel batch operation, data and graph display, analysis and reporting |
| Series connection of multiple instruments | Supported configuration | Emulation of additional series-connected battery cells with software-based remote control |
Mechanical data and operating environment
| Characteristic | Specification |
|---|---|
| Form factor | 19-inch, 2U |
| Dimensions | 88.0 mm (H) × 482.0 mm (W, with handle) × 568.5 mm (D) |
| Net weight | Approx. 20 kg |
| AC input | Single-phase, 220 V AC ± 10%, current < 2 A, 47–63 Hz |
| Operating temperature | 0–40 °C |
| Storage temperature | −20 to +60 °C |
| Environmental conditions | Altitude < 2,000 m; 5–90% relative humidity, non-condensing; 80–110 kPa |
| Isolation | 500 V DC between channels; 1,000 V DC output to ground |
N8330 FAQ
Which N8330 model is suitable for the application?
The N8330A provides 24 channels up to 6 V and 1 A. The N8330B and N8330C provide 16 channels up to 5 V at 2 A or 3 A respectively.
Can multiple instruments be connected as a battery stack?
Yes. Multiple N8330 instruments can be connected in series for additional series-connected cells and remotely controlled through the application software.
How is the influence of the connecting leads reduced?
Four-wire sensing uses two leads for the output and two separate sense leads to measure voltage directly at the DUT.
Which automation capabilities are available?
LAN and isolated RS485 provide remote control. The application software supports batch operation, graph display, analysis and reporting.
How quickly does the output respond to load changes?
For a 10 to 90% load change at full output voltage, the specified recovery time to within ± 50 mV is no more than 200 µs.
Can the N8330 be used for BMS and CMS testing?
Yes. Its isolated, independently programmable channels emulate cell voltages for BMS and CMS testing in vehicles, UAVs and energy storage systems.
Is the series suitable for portable electronics?
Yes. Its stated application fields include R&D and production of mobile phones, Bluetooth earphones, smartwatches and comparable portable devices.
Can voltage acquisition devices be calibrated?
Yes. Its precise cell voltages are suited to calibrating voltage acquisition devices such as fuel-cell voltage monitors.
Technical consultation and project enquiry
Selecting a suitable N8330 configuration requires the channel count, cell voltage, current limit and power per channel. Also consider the planned series connection, accuracy and dynamic requirements, interfaces and test-system architecture.