Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N62406S-10-180

Description
N62406S-10-180 Low-voltage high-current electronic DC load, 600 W, 10 V, 180 A, min. operating voltage 0.2 V
Current [A]
180
Power [P]
600
Voltage [V]
10
N62406S-10-180
N62406S-10-180 Low-voltage high-current electronic DC load, 600 W, 10 V, 180 A, min. operating voltage 0.2 V
180
600
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62412S-10-360

Description
N62412S-10-360 Low-voltage high-current electronic DC load, 1.2 kW, 10 V, 360 A, min. operating voltage 0.2 V
Current [A]
360
Power [P]
1200
Voltage [V]
10
N62412S-10-360
N62412S-10-360 Low-voltage high-current electronic DC load, 1.2 kW, 10 V, 360 A, min. operating voltage 0.2 V
360
1200
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62418S-10-540

Description
N62418S-10-540 Low-voltage high-current electronic DC load, 1.8 kW, 10 V, 540 A, min. operating voltage 0.2 V
Current [A]
540
Power [P]
1800
Voltage [V]
10
N62418S-10-540
N62418S-10-540 Low-voltage high-current electronic DC load, 1.8 kW, 10 V, 540 A, min. operating voltage 0.2 V
540
1800
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62424S-10-270

Description
N62424S-10-270 Low-voltage high-current electronic DC load, 2.4 kW, 10 V, 720 A, min. operating voltage 0.2 V
Current [A]
720
Power [P]
2400
Voltage [V]
10
N62424S-10-270
N62424S-10-270 Low-voltage high-current electronic DC load, 2.4 kW, 10 V, 720 A, min. operating voltage 0.2 V
720
2400
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62436S-10-1080

Description
N62436S-10-1080 Low-voltage high-current electronic DC load, 3.6 kW, 10 V, 1080 A, min. operating voltage 0.2 V
Current [A]
1080
Power [P]
3600
Voltage [V]
10
N62436S-10-1080
N62436S-10-1080 Low-voltage high-current electronic DC load, 3.6 kW, 10 V, 1080 A, min. operating voltage 0.2 V
1080
3600
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62448S-10-1440

Description
N62448S-10-1440 Low-voltage high-current electronic DC load, 3.6 kW, 10 V, 1440 A, min. operating voltage 0.2 V
Current [A]
1440
Power [P]
3600
Voltage [V]
10
N62448S-10-1440
N62448S-10-1440 Low-voltage high-current electronic DC load, 3.6 kW, 10 V, 1440 A, min. operating voltage 0.2 V
1440
3600
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62460S-10-1800

Description
N62460S-10-1800 Low-voltage high-current electronic DC load, 6 kW, 10 V, 1800 A, min. operating voltage 0.2 V
Current [A]
1800
Power [P]
6000
Voltage [V]
10
N62460S-10-1800
N62460S-10-1800 Low-voltage high-current electronic DC load, 6 kW, 10 V, 1800 A, min. operating voltage 0.2 V
1800
6000
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62472S-10-2160

Description
N62472S-10-2160 Low-voltage high-current electronic DC load, 7.2 kW, 10 V, 2160 A, min. operating voltage 0.2 V
Current [A]
2160
Power [P]
7200
Voltage [V]
10
N62472S-10-2160
N62472S-10-2160 Low-voltage high-current electronic DC load, 7.2 kW, 10 V, 2160 A, min. operating voltage 0.2 V
2160
7200
10
Fuel-Cell Test Load

Technical Data

Height

12

6

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

High Current

N62400S DC electronic load overview

The N62400S is a programmable DC electronic load for low-voltage, high-current testing with extended operation at negative cell voltages. Eight power versions provide 600 W to 7.2 kW and 180 to 2,160 A, with a maximum input voltage of 10 V. The series particularly supports fuel cell experiments in which cell voltage passes through zero and becomes negative under load. The reverse polarity test measures the interval between a trigger event or trigger voltage and a defined end voltage. CC, CV, CR and CP operation, dynamic load changes and automatically evaluated sequences supplement this function. Remote sense measures voltage directly at the DUT. Depending on the power rating, compact instruments, larger assemblies or cabinet versions are available. Model selection depends on the complete operating point, the required negative voltage range and the test system requirements.

Key benefits

Investigate voltage reversal

The RP test measures the time to a negative cell-voltage endpoint, supporting fuel cell investigation during voltage reversal.

Measure cell voltage directly

Remote sense reduces the effect of high-current cable voltage drops on voltage measurement and regulation.

Reproduce load changes

Conti, Pulse and Toggle support defined load changes with individually adjustable rise and fall slew rates.

Evaluate test steps automatically

Sequences combine load values and dwell times with voltage, current or power limit checks and PASS/FAIL results.

Determine the power point

The MPPT function examines solar sources using CV-based scans within the 10 V input limit and the current and power limits.

Optional internal resistance test

Optional DCIR measurement determines battery and supercapacitor DC internal resistance from their response to a current step.

Operating principle

The N62400S regulates loading in CC, CV, CR or CP mode. Extended low-voltage operation supports fuel cell testing at zero and negative cell voltages. The RP test applies a defined current and measures the time to a selected negative endpoint. Voltage reversal in a correctly connected DUT and reversed connecting cables are different conditions; RP testing does not replace correct wiring.

Models and operating range

Model / versionMax. voltageRated currentRated power
N62406S-10-18010 V180 A600 W
N62412S-10-36010 V360 A1,200 W
N62418S-10-54010 V540 A1,800 W
N62424S (720 A version)10 V720 A2,400 W
N62436S-10-108010 V1,080 A3,600 W
N62448S-10-144010 V1,440 A4,800 W
N62460S-10-180010 V1,800 A6,000 W
N62472S-10-216010 V2,160 A7,200 W

Voltage, current and power ratings must be considered together. At positive input voltages within the permitted operating envelope, P = U × I and I ≤ min(I-rated, P-rated/U).

Dynamic operation and measurement

Dynamic testing supports current, voltage, resistance and power. Conti alternates continuously between two load levels, Pulse produces a timed change after a trigger and Toggle changes level on each trigger. Slew rates and dwell times are programmable. Actual transition time depends on the selected current change, regulation and connecting cables.

PropertyValue
Voltage setting accuracy0.025% + 0.025% F.S.
Voltage readback accuracy0.025% + 0.025% F.S.
Current readback accuracy0.05% + 0.05% F.S.
CV setting resolution0.1 mV / 1 mV

Accuracy values apply at 23 ±5°C. Allow 30 minutes of warm-up for precision measurements; F.S. denotes the full scale of the selected range.Measurement accuracy applies within one year after calibration.

Operating modes and test functions

FunctionOperationPurpose
CC / CV / CR / CPSteady-state current, voltage, resistance or power regulation.Set defined load conditions.
RP testTime measurement between a trigger event or trigger voltage and a negative endpoint.Investigate fuel cell voltage reversal.
SEQ / Auto Test100 files with up to 50 steps, linking and electrical acceptance limits.Repeatable testing with PASS/FAIL evaluation.
Discharge testConstant current discharge to a defined end voltage.Load batteries and supercapacitors.
Charge testExternal power supply in series with the load and storage device; remote sense required.Test CC and CC/CV charging with an external energy source.
MPPTCV-mode Scan/Trace; MPP, Vmp, Imp, Voc and Isc results.Characterise solar sources within the 10 V, current and power limits.
OCP / short-circuit simulationCurrent steps to test the overcurrent response; short-circuit simulation as an additional test function.Investigate a connected source’s protection behaviour.
DCIR / ESR, optionalEvaluate a current step and the resulting voltage change.Determine DC internal resistance.

Typical applications

Batteries and supercapacitors

Perform defined discharge tests or investigate charging with an external power supply; DCIR is optionally available.

Solar sources up to 10 V

Determine the maximum power point using CV-based MPPT scans; open-circuit voltage, current and power must remain within instrument limits.

Interfaces and automation

FeatureFunction
LAN / RS232 / CANDigital interfaces for remote control.
Modbus-RTU / SCPISupported communication protocols; select the specific interface connection for the test system.
APG / trigger / current monitorAnalogue programming in CC mode, local and external triggers, and current monitoring.
Remote senseVoltage measurement directly at the DUT using S+ and S−.
PC softwareLAN-based instrument control with graphs, data logging and historical measurement data.

Installation and infrastructure

ItemDetails
N62406S / N62412S220 V AC ±10%, 47–63 Hz; 132.5 × 482 × 612 mm, approximately 24 / 31 kg.
N62418S / N62424SThree-phase, five-wire, 380 V AC / 50 Hz; 265 × 482 × 612 mm, approximately 43 / 50 kg.
N62436S / N62448SThree-phase, five-wire, 380 V AC / 50 Hz; assemblies 487.5 or 619.5 × 482 × 612 mm.
N62460S / N62472SThree-phase, five-wire, 380 V AC / 50 Hz; 22U cabinet, 600 mm wide and 800 mm deep.
Temperature and installationOperation 0–40°C, full-power range 0–25°C; storage −20–60°C. Keep ventilation openings clear and size connections for the test current.

Dimensions are H × W × D, with instrument width including handles; cabinet dimensions are listed separately.

Protection and load enable

OVP, OCP and OPP turn off the load when enabled protection thresholds are exceeded. Temperature and module overheating monitoring stop loading in the event of overheating; oscillation monitoring can shut down the load if abnormal load-current behaviour is detected. Von/Voff controls loading according to input voltage in CC mode; Von must exceed Voff. Latch mode prevents automatic restarting after unloading. RP timing and reverse connection detection serve different purposes.

Frequently asked questions

Can 10 V and 2,160 A be used simultaneously?

No. At 10 V, the N62472S-10-2160 is limited by its 7.2 kW rated power to 720 A.

What does loading at negative voltage mean?

A correctly connected fuel cell can develop a negative cell voltage under load. The N62400S supports dedicated operating points and RP testing for this condition.

What time does the RP test measure?

The interval from the selected trigger event or voltage to the defined negative cell-voltage endpoint.

Is DCIR available as standard?

The DCIR/ESR measurement function is optional.

Can the N62400S charge batteries on its own?

Charge testing requires an external power supply in series with the load and storage device, together with remote sense.

Can the series test fuel cells during voltage reversal?

Yes. The RP test investigates cell behaviour at zero or negative voltage and measures the time to the defined endpoint.

Can low-voltage tests be automated?

Yes. SEQ and Auto Test combine recurring load steps with voltage, current or power acceptance checks.

Technical consultation and project enquiry

Tell us the positive and negative cell-voltage ranges, maximum current, simultaneous power and requirements for RP timing, dynamics and automation. We can help select the N62400S version, plan connections and specify optional DCIR measurement.

Discuss your project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly