N62320-80-30

Description
N62320-80-30 Portable programmable DC electronic load, 200 W, 80 V, 30 A
Current [A]
30
Power [P]
200
Voltage [V]
80
N62320-80-30
N62320-80-30 Portable programmable DC electronic load, 200 W, 80 V, 30 A
30
200
80
Desktop DC Load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

Standard Load

N62300 DC electronic load overview

The N62300 is a programmable DC electronic load for testing small power supplies, DC/DC converters, consumer electronics and batteries. The N62320-80-30 model absorbs up to 200 W and supports input voltages up to 80 V and currents up to 30 A. Each operating point is constrained by voltage, current, power and minimum operating voltage simultaneously.

CC, CV, CR and CP modes provide different loading conditions. Two ranges per controlled quantity accommodate both small and larger setpoints. Front-panel keys, a rotary knob and a display for settings and measurements support local operation. Stored settings and programmable sequences simplify recurring tasks in development, production and bench repair. With a width of 72 mm and an approximate weight of 2.6 kg, the load requires little bench space. An optional 4U rack mounting arrangement accommodates up to six load channels.

Key benefits

Select the appropriate range

Two ranges per controlled quantity provide finer settings at low values, including 1 mA resolution in the 3 A current range.

Repeatable test routines

SEQ combines up to 25 steps per group with repetitions, group linking and limits for voltage, current or power.

Recall settings quickly

Four memory groups with 25 locations each keep frequently used instrument settings ready for the next device under test.

Defined switching thresholds

Von and Voff make load enabling and disabling dependent on configurable voltage values.

Investigate short-circuit behaviour

Short-circuit simulation supplements normal load points to investigate how a connected DC supply behaves under this test condition.

Record measurements on a PC

The PC application software displays measured quantities graphically and stores logged data in its history.

Operating principle and load modes

ModeControlled quantityTest task
CC – Constant currentMaintains the configured load current.Load power supplies and batteries at a defined current.
CV – Constant voltageRegulates the input voltage by adjusting the current drawn.Investigate DC sources at a specified voltage point.
CR – Constant resistanceAdjusts the voltage-to-current ratio according to the resistance setpoint.Emulate a resistive DC load.
CP – Constant powerAdjusts load current to input voltage to absorb the configured power.Load a device at a specified power level.

Model and usable operating range

ModelInput voltageInput currentAbsorbed powerMinimum operating voltage
N62320-80-300–80 V0–30 A0–200 W0.5 V at 3 A; 1.5 V at 30 A

Consider voltage, current and power together: P = U × I applies. For U > 0, within the permitted operating limits, I_max = min(30 A, 200 W/U). At 80 V, the maximum current is therefore 2.5 A. The minimum operating voltage also applies; a nominal range starting at 0 V does not mean full current can be drawn at 0 V.

Ranges, resolution and accuracy

QuantityLow rangeHigh rangeSetting resolution
Voltage0–10 V0–80 V1 mV / 10 mV
Current0–3 A0–30 A1 mA / 10 mA
PowerUp to 20 WUp to 200 W1 mW / 10 mW
ResistanceUp to 999.9 ΩUp to 9,999 Ω0.1 Ω / 1 Ω

Voltage setting accuracy and voltage readback accuracy are each 0.05% + 0.1% F.S.; current setting accuracy and current readback accuracy are each 0.1% + 0.1% F.S. at 23 ±5 °C. F.S. denotes the respective full-scale value. Voltage and current inputs must exceed 10% F.S. to achieve the specified accuracy. Allow a 30-minute warm-up before measurement; measurement accuracy is valid within one year after calibration.

Communication response time is no more than 5 ms. This value describes communication and does not specify current rise time or control bandwidth.

Sequences and programmable functions

FunctionScopeBenefit
SEQFour groups A–D with up to 25 steps each; configurable cycle count and group linking.Combine multiple load points into a repeatable routine.
Step parametersCC, CV, CR or CP, setpoint, delay and optional lower and upper limits for voltage, current or power.Define loading, duration and test limits for each step.
Timing unitsMilliseconds, seconds, minutes and hours.Configure both short and longer holding periods.
Save/RecallFour groups with 25 memory locations each.Reuse prepared settings directly.
Von/Voff and ShortConfigurable load-on and load-off voltages plus short-circuit simulation.Include voltage thresholds and a simulated short circuit in tests.

Typical applications

AC/DC power supplies and DC/DC converters

Connect the load to the DC output. CC, CR and CP provide defined loading of small power supply modules.

Consumer electronics and bench repair

Load supplies for smartphones and mobile devices at the bench and compare measurements using repeatedly recalled settings.

Interfaces, software and automation

EquipmentFunction and scope
RS485Standard serial communication interface.
LANStandard Ethernet port for PC connection, configuration and debugging.
ProtocolsModbus-RTU and SCPI; the specific mapping to the communication path must be considered during integration.
PC application softwareOperation of CC, CV, CR, CP and SEQ, on/off control, short-circuit simulation, graphical display and data logging.
Communication monitoringSoftware settings for timeouts, retries and behaviour following a connection loss.

Enclosure, rack mounting and operating conditions

ItemSpecification
Dimensions and weight131.5 × 72 × 325 mm (H × W × D); approximately 2.6 kg net.
Rack mountingOptional 4U arrangement for up to six load channels.
AC supply110/220 V AC with voltage selector, 50–60 Hz; observe the rear-panel rating and selector position.
TemperatureOperation 0–40 °C; full power up to 30 °C, derating above this temperature. Storage −20–60 °C.
EnvironmentAltitude below 2,000 m; relative humidity 5–90%, non-condensing.
Connections and coolingProvide protective earthing, size load leads for the test current and keep ventilation openings clear.

Protection functions

The N62300 provides overcurrent, overvoltage, overpower and overtemperature protection (OCP, OVP, OPP, OTP). OCP, OVP and OPP values are configurable. A triggered protection event is identified by its type on the error display. Connect the load with correct polarity and operate it within its electrical limits.

Frequently asked questions about the N62300

Can I use 80 V and 30 A simultaneously?

No. At 80 V, the 200 W power rating limits current to 2.5 A. Temperature derating must also be considered at higher ambient temperatures.

How low can the input voltage be?

Minimum operating voltage is 0.5 V at 3 A or 1.5 V at 30 A. The permissible current therefore also depends on input voltage.

How extensive can sequences be?

Four groups with up to 25 steps each are available. Cycle count, group linking, timing and step-specific limits are configurable.

Which PC connections are available?

RS485 and LAN are provided. LAN connects the PC application software for configuration, operation and debugging.

Can the load be rack mounted?

Yes. An optional 4U rack mounting arrangement accommodates up to six load channels.

Can I test AC/DC power supplies and DC/DC converters?

Yes. The N62300 loads their DC outputs in CC, CV, CR or CP within its electrical limits.

Is the series suitable for mobile electronics?

Yes. It is intended for tests on consumer electronics such as smartphones and mobile devices; stored settings support recurring load tests.

Can I load small drone batteries?

Yes. Small batteries can be load tested within 80 V, 30 A and 200 W, with all limits applying simultaneously. CC or CP defines the load, while Voff sets the cutoff voltage.

Technical consultation for the N62300

Tell us your voltage range, load current, required absorbed power, test sequence and preferred PC connection. We can help you select and integrate the appropriate DC electronic load.

Discuss your project requirements with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly