Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N62115-80-20

Description
N62115-80-20 Programmable wide-range DC electronic load, 1.5 kW, 80 V, 20 A, 2U
Current [A]
20
Power [P]
150
Voltage [V]
80
N62115-80-20
N62115-80-20 Programmable wide-range DC electronic load, 1.5 kW, 80 V, 20 A, 2U
20
150
80
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62115-150-20

Description
N62115-150-20 Programmable wide-range DC electronic load, 1.5 kW, 150 V, 20 A, 2U
Current [A]
20
Power [P]
150
Voltage [V]
150
N62115-150-20
N62115-150-20 Programmable wide-range DC electronic load, 1.5 kW, 150 V, 20 A, 2U
20
150
150
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62115-600-05

Description
N62115-600-05 Programmable wide-range DC electronic load, 1.5 kW, 600 V, 5 A, 2U
Current [A]
5
Power [P]
150
Voltage [V]
600
N62115-600-05
N62115-600-05 Programmable wide-range DC electronic load, 1.5 kW, 600 V, 5 A, 2U
5
150
600
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62130-80-40

Description
N62130-80-40 Programmable wide-range DC electronic load, 3 kW, 80 V, 40 A, 2U
Current [A]
40
Power [P]
300
Voltage [V]
80
N62130-80-40
N62130-80-40 Programmable wide-range DC electronic load, 3 kW, 80 V, 40 A, 2U
40
300
80
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62130-150-40

Description
N62130-150-40 Programmable wide-range DC electronic load, 3 kW, 150 V, 40 A, 2U
Current [A]
40
Power [P]
300
Voltage [V]
150
N62130-150-40
N62130-150-40 Programmable wide-range DC electronic load, 3 kW, 150 V, 40 A, 2U
40
300
150
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62130-600-10

Description
N62130-600-10 Programmable wide-range DC electronic load, 3 kW, 600 V, 10 A, 2U
Current [A]
10
Power [P]
300
Voltage [V]
600
N62130-600-10
N62130-600-10 Programmable wide-range DC electronic load, 3 kW, 600 V, 10 A, 2U
10
300
600
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62160-80-60

Description
N62160-80-60 Programmable wide-range DC electronic load, 6 kW, 80 V, 60 A, 2U
Current [A]
60
Power [P]
600
Voltage [V]
80
N62160-80-60
N62160-80-60 Programmable wide-range DC electronic load, 6 kW, 80 V, 60 A, 2U
60
600
80
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62160-150-60

Description
N62160-150-60 Programmable wide-range DC electronic load, 6 kW, 150 V, 60 A, 2U
Current [A]
60
Power [P]
600
Voltage [V]
150
N62160-150-60
N62160-150-60 Programmable wide-range DC electronic load, 6 kW, 150 V, 60 A, 2U
60
600
150
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62160-600-15

Description
N62160-600-15 Programmable wide-range DC electronic load, 6 kW, 600 V, 15 A, 2U
Current [A]
15
Power [P]
600
Voltage [V]
600
N62160-600-15
N62160-600-15 Programmable wide-range DC electronic load, 6 kW, 600 V, 15 A, 2U
15
600
600
Desktop DC Load

Technical Data

Height

2

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Single channel

Product category

DC Electronic Load

Type of DC Load

Benchtop Unit

N62100 DC electronic load overview

The N62100 is a programmable DC electronic load for performance and functional testing of power supplies, DC/DC converters, LED drivers, electronic components and energy storage devices. The 80 V and 150 V models described here cover 150, 300 and 600 W. Maximum input current is 20, 40 or 60 A, depending on the power class. Every operating point must remain within the voltage, current and power limits of the selected instrument.

Static load characteristics are complemented by dynamic operation, combined control modes and dedicated tests. Auto Test can combine different basic operating modes in one routine; SEQ provides programmable current sequences. Local operation uses a 4.3-inch LCD, function keys, numeric keypad and rotary knob. LAN and RS232 connect the benchtop instrument to computer-controlled test stations. Remote sense measures voltage directly at the device under test, reducing the influence of voltage drops in the load cables on voltage measurement.

Key benefits

Ranges matched to the test

Dual ranges for voltage, current, resistance and power adapt settings and measurements to the required operating point.

Test steps with limits

Up to ten Auto Test files with 200 steps each combine load settings with voltage, current or power acceptance limits.

Defined LED load simulation

Voltage, current and resistance coefficient define the LED simulation for electrical testing of LED drivers.

Measure voltage at the DUT

Separate S+/S− terminals support accurate voltage measurement when the current-carrying cables introduce significant voltage drops.

Controlled discharge termination

Configurable voltage, time, capacity and energy termination criteria support repeatable discharge testing.

Observe current externally

The analogue I_MON output provides 0 to 10 V corresponding to 0 A through rated current, for display on an oscilloscope, for example.

Operating principle and modes

The load draws current from the connected DC device under test and regulates it according to the selected characteristic. Combined modes add a further control variable or limit.

ModeOperation and purpose
CCConstant current for a defined current load.
CVAdjusts the current drawn to maintain the input voltage at the setpoint.
CRResistive behaviour: current follows input voltage according to the resistance setting.
CPConstant power consumption: the required current decreases as voltage rises.
CV+CCConstant voltage with current limiting, for example to simulate the operating-mode transition during battery charging.
CR+CCResistive behaviour with current limiting, for example for power supply start-up testing.
CP+CCConstant power with current limiting as input voltage falls.
CV+CRCombines constant-voltage and resistive behaviour with configurable voltage and resistance values.

Power range and model selection

ModelMax. voltageMax. currentRated power
N62115-80-2080 V20 A150 W
N62115-150-20150 V20 A150 W
N62130-80-4080 V40 A300 W
N62130-150-40150 V40 A300 W
N62160-80-6080 V60 A600 W
N62160-150-60150 V60 A600 W

The limits apply together: P = U × I. For U > 0, within the permitted operating region, I_max = min(I_rated, P_rated/U). At 150 V, the N62160-150-60 therefore supports no more than 4 A within its 600 W rating; 60 A at 150 V is not a continuous operating point.

The current-dependent minimum operating voltage must also be considered. For both 600 W models, it is 0.5 V at 6 A and 1.5 V at 60 A.

Dynamic behaviour and measurements

CCD, CVD, CRD and CPD provide dynamic load changes in current, voltage, resistance and power operation respectively. Continuous switching and triggered Pulse and Toggle routines are available. Current rise and fall slew rates are configurable, and CV loop response can be adjusted.

Power classLow current rangeHigh current range
150 W / 20 A0.2–200 A/ms2–2,000 A/ms
300 W / 40 A0.4–400 A/ms4–4,000 A/ms
600 W / 60 A0.6–600 A/ms6–6,000 A/ms

These slew values are setting ranges; the test setup and cable inductance influence the actual current waveform. The display also provides minimum, maximum and peak-to-peak voltage and current readings.

Programmable test and simulation functions

FunctionTest task
Dynamic SweepVaries frequency between two current levels to investigate critical voltage dips or peaks.
OCP / OPPIncreases current or power in steps until the defined voltage criterion is reached, determining the DUT protection trip point.
OVP testCaptures the voltage peak and falling edge to determine the DUT overvoltage protection point and response time.
Load EffectEvaluates the change in power supply output voltage as current loading changes.
Time TestMeasures switching, hold-up, rise and fall times using defined trigger conditions.
Auto Test / SEQUp to ten files with 200 steps each: Auto Test for CC/CV/CR/CP routines, SEQ for CC current sequences.
Impedance simulationSimulates resistive, inductive and capacitive load components for application-specific load conditions.
Short-circuit simulationElectronic short-circuit simulation to test DUT behaviour; current draw depends on operating mode and current range.
Von/VoffVoltage-dependent load activation and deactivation for defined start and stop conditions.

Typical applications

Power supplies and DC/DC converters

Static load characteristics, load changes and protection tests assess the output behaviour of AC/DC supplies, DC/DC converters and communication power supplies.

LED drivers

LED simulation reproduces an adjustable electrical LED load and supports evaluation of driver current, including ripple.

Batteries and supercapacitors

The discharge function loads the energy storage device with a defined current and ends the routine using the configured termination criteria.

Automotive component testing

Wiring harnesses, connectors, fuses, relays and central electrical distribution units can be tested under defined DC load conditions.

Fast-charge adapters and power banks

On N62115-150-20 and N62130-150-40, electrical load testing can be complemented by an optional fast-charge test module for protocol detection.

Repeatable test routines

Auto Test combines load steps and electrical limit checks for recurring functional tests; SEQ reproduces defined current profiles.

Interfaces, software and options

EquipmentFunction and scope
LAN / RS232Communication interfaces for remote control. Supported protocols: SCPI, Modbus-RTU and TCP/IP; port and protocol configuration must match the controller.
S+/S−Remote-sense input for voltage measurement directly at the DUT output terminals.
TRIGExternal control input compatible with 5 V TTL levels; Toggle and Hold behaviour for load control.
I_MONAnalogue current monitor output: 0–10 V corresponds to 0 A through rated current.
Front USBUSB memory connection, for example for saving screenshots.
PC application softwareOperation over LAN, parameter configuration, measurement display and data logging.
Fast-charge test module, optionalOnly for N62115-150-20 and N62130-150-40. Supports USB PD2.0/PD3.0/PD3.1 and QC2.0/QC3.0, among others; QC Detect identifies protocols supported by the connected DUT.

Installation and operating conditions

ItemSpecification
AC supply110/220 V AC, 47–63 Hz; check the voltage selector and rear-panel marking before connection.
Operating temperature0 to 40 °C
Storage temperature−20 to 60 °C
EnvironmentAltitude below 2,000 m; 5–90% relative humidity, non-condensing.
Weight150 W models approximately 4.5 kg; 300 W and 600 W models approximately 5 kg.
DUT connectionSelect load cables to suit the current and test setup, observe correct polarity and keep the rear air outlet unobstructed.

Protection functions

Programmable OCP, OVP and OPP thresholds monitor input current, input voltage and input power. A trip switches the load off. Internal overtemperature protection stops loading and raises an alarm. RV/RC alarms indicate detected reverse voltage or current direction; correct connection polarity is required.

The instrument protection functions are separate from the OCP, OPP and OVP test routines, which evaluate the protection behaviour of the connected DUT.

Frequently asked questions about the N62100

Can 150 V and 60 A be used simultaneously?

For the 600 W model, the power rating limits current to 4 A at 150 V. The current limit and permitted operating characteristic also apply.

When is remote sense useful?

When voltage drop in the load cables affects measurement. S+ and S− connect directly to the DUT terminals; this is particularly relevant in CV, CR and CP operation.

How do Auto Test and SEQ differ?

Auto Test can use CC, CV, CR and CP within one routine. SEQ creates CC current sequences. Both support up to ten files with 200 steps each.

Which dynamic modes are available?

CCD, CVD, CRD and CPD with continuous operation and triggered Pulse and Toggle routines.

How can current be displayed externally?

I_MON provides 0–10 V corresponding to 0 A through rated current. An external oscilloscope can display this waveform.

Can LED power supplies be tested?

Yes. LED simulation uses configurable voltage, current and resistance parameters to reproduce the electrical load characteristic of an LED.

Can batteries and supercapacitors be tested?

Yes. The discharge test uses a configured current and voltage, time, capacity or energy termination criteria. Current multiplied by input voltage must remain below rated power.

Can the N62100 detect fast-charge protocols?

With the optional fast-charge test module on N62115-150-20 and N62130-150-40. QC Detect scans the protocols supported by the connected fast-charge device.

Technical consultation for your N62100 project

Tell us about your DUT, voltage range, load current, power requirements and planned test routines. We can assist with model selection and questions about dynamic behaviour, remote sense, automation and the optional fast-charge test module.

Discuss your N62100 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly