CC, CV, CR and CP plus four combined modes reproduce different electrical load characteristics for your test requirements.
N62100 – Electronic DC Load up to 600 W with LED Simulation
For LED driver, power supply and battery testing with combined load modes, dynamic sweeps and discharge functions.
The N62100 combines conventional DC load functions, combined operating modes and dedicated test routines in a benchtop instrument. Dual ranges for voltage, current, resistance and power help adapt the load to different operating points, from power supply development to repeatable functional testing.
Adjustable current slew rates, dynamic tests and frequency sweeps help investigate power supply behaviour under changing load conditions.
LED simulation, discharge testing and OCP, OPP and OVP tests support targeted evaluation of power supplies and energy storage devices.
LAN and RS232 enable remote control, while Auto Test and SEQ execute stored test steps with defined setpoints.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
N62115-80-20 Programmable wide-range DC electronic load, 1.5 kW, 80 V, 20 A, 2U
|
Current [A]
20
|
Power [P]
150
|
Voltage [V]
80
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62115-150-20 Programmable wide-range DC electronic load, 1.5 kW, 150 V, 20 A, 2U
|
Current [A]
20
|
Power [P]
150
|
Voltage [V]
150
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62115-600-05 Programmable wide-range DC electronic load, 1.5 kW, 600 V, 5 A, 2U
|
Current [A]
5
|
Power [P]
150
|
Voltage [V]
600
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62130-80-40 Programmable wide-range DC electronic load, 3 kW, 80 V, 40 A, 2U
|
Current [A]
40
|
Power [P]
300
|
Voltage [V]
80
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62130-150-40 Programmable wide-range DC electronic load, 3 kW, 150 V, 40 A, 2U
|
Current [A]
40
|
Power [P]
300
|
Voltage [V]
150
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62130-600-10 Programmable wide-range DC electronic load, 3 kW, 600 V, 10 A, 2U
|
Current [A]
10
|
Power [P]
300
|
Voltage [V]
600
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62160-80-60 Programmable wide-range DC electronic load, 6 kW, 80 V, 60 A, 2U
|
Current [A]
60
|
Power [P]
600
|
Voltage [V]
80
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62160-150-60 Programmable wide-range DC electronic load, 6 kW, 150 V, 60 A, 2U
|
Current [A]
60
|
Power [P]
600
|
Voltage [V]
150
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
|
Description
N62160-600-15 Programmable wide-range DC electronic load, 6 kW, 600 V, 15 A, 2U
|
Current [A]
15
|
Power [P]
600
|
Voltage [V]
600
|
Technical Data
Height
2
max. Current (A)
max. power (W)
max. voltage (V)
Number of channels
Single channel
Product category
DC Electronic Load
Type of DC Load
Benchtop Unit
N62100 DC electronic load overview
The N62100 is a programmable DC electronic load for performance and functional testing of power supplies, DC/DC converters, LED drivers, electronic components and energy storage devices. The 80 V and 150 V models described here cover 150, 300 and 600 W. Maximum input current is 20, 40 or 60 A, depending on the power class. Every operating point must remain within the voltage, current and power limits of the selected instrument.
Static load characteristics are complemented by dynamic operation, combined control modes and dedicated tests. Auto Test can combine different basic operating modes in one routine; SEQ provides programmable current sequences. Local operation uses a 4.3-inch LCD, function keys, numeric keypad and rotary knob. LAN and RS232 connect the benchtop instrument to computer-controlled test stations. Remote sense measures voltage directly at the device under test, reducing the influence of voltage drops in the load cables on voltage measurement.
Key benefits
Ranges matched to the test
Dual ranges for voltage, current, resistance and power adapt settings and measurements to the required operating point.
Test steps with limits
Up to ten Auto Test files with 200 steps each combine load settings with voltage, current or power acceptance limits.
Defined LED load simulation
Voltage, current and resistance coefficient define the LED simulation for electrical testing of LED drivers.
Measure voltage at the DUT
Separate S+/S− terminals support accurate voltage measurement when the current-carrying cables introduce significant voltage drops.
Controlled discharge termination
Configurable voltage, time, capacity and energy termination criteria support repeatable discharge testing.
Observe current externally
The analogue I_MON output provides 0 to 10 V corresponding to 0 A through rated current, for display on an oscilloscope, for example.
Operating principle and modes
The load draws current from the connected DC device under test and regulates it according to the selected characteristic. Combined modes add a further control variable or limit.
| Mode | Operation and purpose |
|---|---|
| CC | Constant current for a defined current load. |
| CV | Adjusts the current drawn to maintain the input voltage at the setpoint. |
| CR | Resistive behaviour: current follows input voltage according to the resistance setting. |
| CP | Constant power consumption: the required current decreases as voltage rises. |
| CV+CC | Constant voltage with current limiting, for example to simulate the operating-mode transition during battery charging. |
| CR+CC | Resistive behaviour with current limiting, for example for power supply start-up testing. |
| CP+CC | Constant power with current limiting as input voltage falls. |
| CV+CR | Combines constant-voltage and resistive behaviour with configurable voltage and resistance values. |
Power range and model selection
| Model | Max. voltage | Max. current | Rated power |
|---|---|---|---|
| N62115-80-20 | 80 V | 20 A | 150 W |
| N62115-150-20 | 150 V | 20 A | 150 W |
| N62130-80-40 | 80 V | 40 A | 300 W |
| N62130-150-40 | 150 V | 40 A | 300 W |
| N62160-80-60 | 80 V | 60 A | 600 W |
| N62160-150-60 | 150 V | 60 A | 600 W |
The limits apply together: P = U × I. For U > 0, within the permitted operating region, I_max = min(I_rated, P_rated/U). At 150 V, the N62160-150-60 therefore supports no more than 4 A within its 600 W rating; 60 A at 150 V is not a continuous operating point.
The current-dependent minimum operating voltage must also be considered. For both 600 W models, it is 0.5 V at 6 A and 1.5 V at 60 A.
Dynamic behaviour and measurements
CCD, CVD, CRD and CPD provide dynamic load changes in current, voltage, resistance and power operation respectively. Continuous switching and triggered Pulse and Toggle routines are available. Current rise and fall slew rates are configurable, and CV loop response can be adjusted.
| Power class | Low current range | High current range |
|---|---|---|
| 150 W / 20 A | 0.2–200 A/ms | 2–2,000 A/ms |
| 300 W / 40 A | 0.4–400 A/ms | 4–4,000 A/ms |
| 600 W / 60 A | 0.6–600 A/ms | 6–6,000 A/ms |
These slew values are setting ranges; the test setup and cable inductance influence the actual current waveform. The display also provides minimum, maximum and peak-to-peak voltage and current readings.
Programmable test and simulation functions
| Function | Test task |
|---|---|
| Dynamic Sweep | Varies frequency between two current levels to investigate critical voltage dips or peaks. |
| OCP / OPP | Increases current or power in steps until the defined voltage criterion is reached, determining the DUT protection trip point. |
| OVP test | Captures the voltage peak and falling edge to determine the DUT overvoltage protection point and response time. |
| Load Effect | Evaluates the change in power supply output voltage as current loading changes. |
| Time Test | Measures switching, hold-up, rise and fall times using defined trigger conditions. |
| Auto Test / SEQ | Up to ten files with 200 steps each: Auto Test for CC/CV/CR/CP routines, SEQ for CC current sequences. |
| Impedance simulation | Simulates resistive, inductive and capacitive load components for application-specific load conditions. |
| Short-circuit simulation | Electronic short-circuit simulation to test DUT behaviour; current draw depends on operating mode and current range. |
| Von/Voff | Voltage-dependent load activation and deactivation for defined start and stop conditions. |
Typical applications
Power supplies and DC/DC converters
Static load characteristics, load changes and protection tests assess the output behaviour of AC/DC supplies, DC/DC converters and communication power supplies.
LED drivers
LED simulation reproduces an adjustable electrical LED load and supports evaluation of driver current, including ripple.
Batteries and supercapacitors
The discharge function loads the energy storage device with a defined current and ends the routine using the configured termination criteria.
Automotive component testing
Wiring harnesses, connectors, fuses, relays and central electrical distribution units can be tested under defined DC load conditions.
Fast-charge adapters and power banks
On N62115-150-20 and N62130-150-40, electrical load testing can be complemented by an optional fast-charge test module for protocol detection.
Repeatable test routines
Auto Test combines load steps and electrical limit checks for recurring functional tests; SEQ reproduces defined current profiles.
Interfaces, software and options
| Equipment | Function and scope |
|---|---|
| LAN / RS232 | Communication interfaces for remote control. Supported protocols: SCPI, Modbus-RTU and TCP/IP; port and protocol configuration must match the controller. |
| S+/S− | Remote-sense input for voltage measurement directly at the DUT output terminals. |
| TRIG | External control input compatible with 5 V TTL levels; Toggle and Hold behaviour for load control. |
| I_MON | Analogue current monitor output: 0–10 V corresponds to 0 A through rated current. |
| Front USB | USB memory connection, for example for saving screenshots. |
| PC application software | Operation over LAN, parameter configuration, measurement display and data logging. |
| Fast-charge test module, optional | Only for N62115-150-20 and N62130-150-40. Supports USB PD2.0/PD3.0/PD3.1 and QC2.0/QC3.0, among others; QC Detect identifies protocols supported by the connected DUT. |
Installation and operating conditions
| Item | Specification |
|---|---|
| AC supply | 110/220 V AC, 47–63 Hz; check the voltage selector and rear-panel marking before connection. |
| Operating temperature | 0 to 40 °C |
| Storage temperature | −20 to 60 °C |
| Environment | Altitude below 2,000 m; 5–90% relative humidity, non-condensing. |
| Weight | 150 W models approximately 4.5 kg; 300 W and 600 W models approximately 5 kg. |
| DUT connection | Select load cables to suit the current and test setup, observe correct polarity and keep the rear air outlet unobstructed. |
Protection functions
Programmable OCP, OVP and OPP thresholds monitor input current, input voltage and input power. A trip switches the load off. Internal overtemperature protection stops loading and raises an alarm. RV/RC alarms indicate detected reverse voltage or current direction; correct connection polarity is required.
The instrument protection functions are separate from the OCP, OPP and OVP test routines, which evaluate the protection behaviour of the connected DUT.
Frequently asked questions about the N62100
Can 150 V and 60 A be used simultaneously?
For the 600 W model, the power rating limits current to 4 A at 150 V. The current limit and permitted operating characteristic also apply.
When is remote sense useful?
When voltage drop in the load cables affects measurement. S+ and S− connect directly to the DUT terminals; this is particularly relevant in CV, CR and CP operation.
How do Auto Test and SEQ differ?
Auto Test can use CC, CV, CR and CP within one routine. SEQ creates CC current sequences. Both support up to ten files with 200 steps each.
Which dynamic modes are available?
CCD, CVD, CRD and CPD with continuous operation and triggered Pulse and Toggle routines.
How can current be displayed externally?
I_MON provides 0–10 V corresponding to 0 A through rated current. An external oscilloscope can display this waveform.
Can LED power supplies be tested?
Yes. LED simulation uses configurable voltage, current and resistance parameters to reproduce the electrical load characteristic of an LED.
Can batteries and supercapacitors be tested?
Yes. The discharge test uses a configured current and voltage, time, capacity or energy termination criteria. Current multiplied by input voltage must remain below rated power.
Can the N62100 detect fast-charge protocols?
With the optional fast-charge test module on N62115-150-20 and N62130-150-40. QC Detect scans the protocols supported by the connected fast-charge device.
Technical consultation for your N62100 project
Tell us about your DUT, voltage range, load current, power requirements and planned test routines. We can assist with model selection and questions about dynamic behaviour, remote sense, automation and the optional fast-charge test module.