ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N6136-100-05

Description
N6136-100-05 Multi-channel programmable DC electronic load, 36 channels, 50 W per channel, 100 V, 5 A, 3U
Current [A]
5
Power [P]
50
Voltage [V]
100
N6136-100-05
N6136-100-05 Multi-channel programmable DC electronic load, 36 channels, 50 W per channel, 100 V, 5 A, 3U
5
50
100
36/48 CH DC Load

Technical Data

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Product category

DC Electronic Load

Type of DC Load

Multi-channel

N6148-100-05

Description
N6148-100-05 Multi-channel programmable DC electronic load, 48 channels, 50 W per channel, 100 V, 5 A, 3U
Current [A]
5
Power [P]
50
Voltage [V]
100
N6148-100-05
N6148-100-05 Multi-channel programmable DC electronic load, 48 channels, 50 W per channel, 100 V, 5 A, 3U
5
50
100
36/48 CH DC Load

Technical Data

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Product category

DC Electronic Load

Type of DC Load

Multi-channel

N6148 Series overview

The N6148 Series is a programmable multi-channel DC electronic load for integrated test stations and parallel testing of multiple devices under test. The N6136-100-05 and N6148-100-05 provide 36 and 48 load channels respectively in a 19-inch, 3U chassis. Each channel supports up to 100 V, 5 A and 50 W. Available functions include constant current, constant resistance and constant power operation, dynamic current profiles, automated OCP testing and adjustable Von/Voff thresholds. Typical applications include DC/DC converters, power assemblies, wiring harnesses, connectors, fuses, relays and Bussed Electrical Centers. The high channel density allows numerous low-power standalone loads to be replaced by one centrally controlled unit in production, ageing and quality-control systems. LAN and RS485 with SCPI and Modbus support integration into ATE and production test equipment.

Key benefits

High channel density

Up to 48 load channels in 3U reduce rack space compared with multiple individual low-power loads.

Modular channel architecture

Each internal power module integrates six channels, providing product variants with 36 or 48 channels.

Defined channel range

Each channel can load a device under test within a range of up to 100 V, 5 A and 50 W.

Integrated protection testing

The automated OCP test increases load current in steps and determines the shutdown behaviour of the DUT.

Local operation

A colour display, function keys, numeric keypad and rotary knob support configuration and monitoring at the instrument.

Automated communication

LAN and RS485 with SCPI and Modbus provide central control and readback of the load channels.

Operating principle of the multi-channel DC electronic load

The N6148 Series loads connected DC sources and components using a programmed current, resistance or power value. The required channel is selected from the local user interface or through remote control. Voltage, current and power are read back during operation together with the selected function and channel status.

Multiple channels within one unit can be configured for different DUTs and monitored through the combined channel overview. The All View function displays operating mode, measured values and on/off status for multiple channels. The N6148 Series is a DC electronic load. Regenerative energy recovery must not be assumed.

Important for system sizing: The ratings of 100 V, 5 A and 50 W apply to each individual channel. The total chassis power must not be calculated from the channel count without separate confirmation.

Models and technical specifications

The two models mainly differ in their channel count and instrument weight. Their electrical channel ranges and programmable operating modes are identical.

Technical characteristic N6136-100-05 N6148-100-05
Number of channels 36 channels 48 channels
Voltage range per channel 0 to 100 V 0 to 100 V
Current range per channel 0 to 5 A 0 to 5 A
Power range per channel 0 to 50 W 0 to 50 W
CC setting resolution 1 mA 1 mA
CC setting accuracy at 23 ±5 °C 0.1% + 0.5% of full scale 0.1% + 0.5% of full scale
CR range 1 Ω to 2 kΩ 1 Ω to 2 kΩ
CR setting resolution 0.1 Ω 0.1 Ω
CR setting accuracy at 23 ±5 °C 0.1% + 0.5% of full scale, at an operating voltage ≥1 V 0.1% + 0.5% of full scale, at an operating voltage ≥1 V
CP setting resolution 10 mW 10 mW
CP setting accuracy at 23 ±5 °C 0.1% + 0.5% of full scale 0.1% + 0.5% of full scale
Voltage measurement 0 to 100 V, 10 mV resolution 0 to 100 V, 10 mV resolution
Voltage measurement accuracy at 23 ±5 °C 0.1% + 0.1% of full scale 0.1% + 0.1% of full scale
Chassis 19 inch, 3U 19 inch, 3U
Dimensions 132.5 × 482 × 500 mm 132.5 × 482 × 500 mm
Weight Approx. 22 kg Approx. 25 kg

Dynamic load profiles and response behaviour

CCD dynamic current operation is available for transient testing. The load channels switch between a primary current level and a second transient current level. Timing parameters can be configured for both current levels.

Continuous

The load continuously alternates between two current levels according to the programmed pulse times and cycle count.

Pulse

After a trigger, the load changes to the transient current for the programmed pulse duration and then returns.

Toggle

Each trigger alternates the selected channel between the primary and transient current values.

Technical distinction: The communication response time is ≤10 ms. This value refers to communication and is not an electrical rise time, current slew rate or settling time of the load channel.

Operating modes and programmable test functions

Function Description Typical use
CC Loads the DUT with a constant programmed current despite changes in the input voltage. Testing power supplies, converters and current-limited assemblies.
CR Emulates a constant resistance, causing load current to change with the applied voltage. Testing resistive load conditions and defined operating points.
CP Maintains constant power by adapting the load current to changes in input voltage. Loading sources and converters at a defined power level.
CCD Dynamic current operation with Continuous, Pulse and Toggle modes. Evaluating DUT behaviour during changing load conditions.
OCP test Increases current in programmed steps until the end condition is reached or the DUT shuts down. Determining and verifying the overcurrent protection threshold of a DUT.
Von/Voff Automatically activates or deactivates the load according to programmable voltage thresholds. Testing switch-on, shutdown and hysteresis behaviour.
All View Combined display of channel, operating mode, voltage, current and status. Monitoring multiple parallel test processes from one overview.

Typical applications

The N6148 Series is particularly suitable for applications requiring many low-power DC devices to be loaded simultaneously with repeatable and automated test conditions.

DC/DC converters and power assemblies

Multiple converters can be loaded simultaneously in CC, CR or CP mode to verify output behaviour and protection shutdown.

Ageing and endurance testing

Multiple DUTs can be operated with defined load values over extended periods and monitored centrally.

Fuses and protection circuits

The stepped OCP test supports the determination of trip and shutdown points in current-limiting components.

Multi-channel quality control

Uniform parameters and centrally readable measurements support repeatable testing of multiple identical products.

Interfaces, software and automation

Function Status Technical use
LAN Standard RJ45 network interface, factory IP address 192.168.0.123 and UDP communication via port 7000.
RS485 Standard Serial remote control with configurable baud rate; factory setting 115200 baud.
SCPI Supported Text-based remote-control protocol for integration into automated measurement and test systems.
Modbus Supported Communication protocol for connection to industrial control and automation environments.
PC software Included Online and offline control, hardware and channel configuration, operating modes, protection parameters and status display.
Multi-unit network Supported Multiple instruments can be connected through one network switch using unique IP addresses.
Local operation Standard 4.3-inch colour display, function keys, numeric keypad and rotary knob.
The PC software supports Microsoft Windows 7 and later Windows versions. Disable the computer’s automatic standby mode to ensure stable endurance testing.

Channel architecture and scaling

The N6148 Series uses a modular architecture with six load channels per internal power module. This provides the N6136-100-05 with 36 channels and the N6148-100-05 with 48 channels. The channel count can therefore be selected according to the number of components that must be tested simultaneously.

Larger test installations can connect multiple instruments to a shared LAN switch and address them using unique IP addresses.

Installation and infrastructure

Requirement Specification
AC input Single-phase, 220 V AC ±10%, 47 to 63 Hz
Instrument fuse 250 V / 10 A, dimensions 20 × 5 mm
Protective earth Operation requires a correctly connected protective-earth conductor.
Rack installation 19-inch, 3U chassis installed with suitable guide rails and front-panel mounting.
Dimensions 132.5 mm high × 482 mm wide × 500 mm deep
Weight N6136-100-05 approx. 22 kg; N6148-100-05 approx. 25 kg
Operating temperature 0 to 40 °C
Storage temperature −20 to 60 °C
Humidity 5 to 90% relative humidity, non-condensing
Altitude Below 2,000 m
Atmospheric pressure 80 to 110 kPa
At high ambient temperatures and operation near rated power, the cooling fan may run at maximum speed. The sound-pressure level can exceed 70 dB at a distance of one metre from the front panel.

Protection and safety functions

Overcurrent protection

A programmable current threshold disconnects the affected load channel when the limit is exceeded.

Overvoltage protection

The adjustable voltage threshold stops loading when an overvoltage condition is detected.

Overpower protection

A programmable power threshold protects the channel against operation outside its permitted range.

Overtemperature protection

The N6148 Series includes overtemperature protection (OTP).

Protective-earth connection

The instrument must be reliably grounded and connected to a mains outlet with protective earth before operation.

Correct polarity

DUT connections must be made with power removed and according to the marked positive and negative terminals.

N6148 Series FAQ

Which model is suitable for my application?

The primary difference is the channel count: the N6136-100-05 provides 36 channels and the N6148-100-05 provides 48 channels.

Do the ratings of 100 V, 5 A and 50 W apply to the complete instrument?

No. The ratings apply to each individual load channel.

Which static operating modes are available?

The series supports constant current CC, constant resistance CR and constant power CP operation.

Can the load generate dynamic current changes?

Yes. CCD mode provides Continuous, Pulse and Toggle operation using two programmable current levels.

How does the automated OCP test operate?

The load increases current in programmed steps while monitoring the input voltage. Shutdown behaviour is determined using the programmed end conditions.

Which interfaces are included as standard?

LAN and RS485 are integrated. SCPI and Modbus are supported for remote control.

Can load channels be connected electrically in parallel?

Electrical parallel or series operation of the channels must not be assumed as an instrument function.

What are the AC input requirements?

The instrument requires a single-phase 220 V AC ±10% supply at 47 to 63 Hz with a correctly connected protective-earth conductor.

Technical consultation and project enquiry

Selection between 36 and 48 channels should consider the number and electrical ratings of the DUTs, required operating modes, test sequences and automation requirements.

ET System supports channel sizing, integration into LAN or RS485 environments and implementation in production and multi-channel test systems. Send your technical requirements through our contact page for technical project enquiries .