Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Beschreibung
Current [A]
Power [P]
Voltage [V]
N61112-80-20

Beschreibung
N61112-80-20 Multi-channel DC load, 150 W, 80 V, 20 A, 12 channels, 3U, sync./async. controllable channels
Current [A]
20
Power [P]
150
Voltage [V]
80
N61112-80-20
N61112-80-20 Multi-channel DC load, 150 W, 80 V, 20 A, 12 channels, 3U, sync./async. controllable channels
20
150
80
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61112-150-20

Beschreibung
N61112-150-20 Multi-channel DC load, 150 W, 150 V, 20 A, 12 channels, 3U, sync./async. controllable channels
Current [A]
20
Power [P]
150
Voltage [V]
150
N61112-150-20
N61112-150-20 Multi-channel DC load, 150 W, 150 V, 20 A, 12 channels, 3U, sync./async. controllable channels
20
150
150
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61112-600-05

Beschreibung
N61112-600-05 Multi-channel DC load, 150 W, 600 V, 5 A, 12 channels, 3U, sync./async. controllable channels
Current [A]
5
Power [P]
150
Voltage [V]
600
N61112-600-05
N61112-600-05 Multi-channel DC load, 150 W, 600 V, 5 A, 12 channels, 3U, sync./async. controllable channels
5
150
600
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61102-600-30

Beschreibung
N61102-600-30 Multi-channel DC load, 900 W, 600 V, 30 A, 2 channels, 3U, sync./async. controllable channels
Current [A]
30
Power [P]
900
Voltage [V]
600
N61102-600-30
N61102-600-30 Multi-channel DC load, 900 W, 600 V, 30 A, 2 channels, 3U, sync./async. controllable channels
30
900
600
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61106-80-40

Beschreibung
N61106-80-40 Multi-channel DC load, 300 W, 80 V, 40 A, 6 channels, 3U, sync./async. controllable channels
Current [A]
40
Power [P]
300
Voltage [V]
80
N61106-80-40
N61106-80-40 Multi-channel DC load, 300 W, 80 V, 40 A, 6 channels, 3U, sync./async. controllable channels
40
300
80
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61106-150-40

Beschreibung
N61106-150-40 Multi-channel DC load, 300 W, 150 V, 40 A, 6 channels, 3U, sync./async. controllable channels
Current [A]
40
Power [P]
300
Voltage [V]
150
N61106-150-40
N61106-150-40 Multi-channel DC load, 300 W, 150 V, 40 A, 6 channels, 3U, sync./async. controllable channels
40
300
150
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61106-600-10

Beschreibung
N61106-600-10 Multi-channel DC load, 300 W, 600 V, 10 A, 6 channels, 3U, sync./async. controllable channels
Current [A]
10
Power [P]
300
Voltage [V]
600
N61106-600-10
N61106-600-10 Multi-channel DC load, 300 W, 600 V, 10 A, 6 channels, 3U, sync./async. controllable channels
10
300
600
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61104-80-60

Beschreibung
N61104-80-60 Multi-channel DC load, 540 W, 80 V, 60 A, 4 channels, 3U, sync./async. controllable channels
Current [A]
60
Power [P]
540
Voltage [V]
80
N61104-80-60
N61104-80-60 Multi-channel DC load, 540 W, 80 V, 60 A, 4 channels, 3U, sync./async. controllable channels
60
540
80
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61104-150-60

Beschreibung
N61104-150-60 Multi-channel DC load, 540 W, 150 V, 60 A, 4 channels, 3U, sync./async. controllable channels
Current [A]
60
Power [P]
540
Voltage [V]
150
N61104-150-60
N61104-150-60 Multi-channel DC load, 540 W, 150 V, 60 A, 4 channels, 3U, sync./async. controllable channels
60
540
150
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61100.1

Beschreibung
N61100.1 Multi-channel DC load, 540 W, 600 V, 15 A, 4 channels, 3U, sync./async. controllable channels
Current [A]
15
Power [P]
540
Voltage [V]
600
N61100.1
N61100.1 Multi-channel DC load, 540 W, 600 V, 15 A, 4 channels, 3U, sync./async. controllable channels
15
540
600
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61102-150-120

Beschreibung
N61102-80-120 Multi-channel DC load, 900 W, 80 V, 120 A, 2 channels, 3U, sync./async. controllable channels
Power [P]
900
Voltage [V]
80
N61102-150-120
N61102-80-120 Multi-channel DC load, 900 W, 80 V, 120 A, 2 channels, 3U, sync./async. controllable channels
900
80
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61102-80-120

Beschreibung
N61102-80-120 Multi-channel DC load, 900 W, 80 V, 120 A, 2 channels, 3U, sync./async. controllable channels
Power [P]
900
Voltage [V]
120
N61102-80-120
N61102-80-120 Multi-channel DC load, 900 W, 80 V, 120 A, 2 channels, 3U, sync./async. controllable channels
900
120
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61100.3

Beschreibung
N61102-150-120 Multi-channel DC load, 900 W, 150 V, 120 A, 2 channels, 3U, sync./async. controllable channels
Current [A]
120
Power [P]
900
Voltage [V]
150
N61100.3
N61102-150-120 Multi-channel DC load, 900 W, 150 V, 120 A, 2 channels, 3U, sync./async. controllable channels
120
900
150
Multi-channel DC load

Technical Data

Height

3

max. Current (A)

max. power (W)

max. voltage (V)

Number of channels

Multichannel

Type of DC Load

Multi-channel

N61100 Series Multi-Channel DC Electronic Load: High-Precision Test Solutions for Industrial R&D and QA Environments

In modern automated test environments, the balance between channel density, precision, and processing speed is a decisive competitive factor. The N61100 series was developed as a highly integrated, programmable DC electronic load in a compact 19-inch 3U format to meet these requirements efficiently.

With a communication response time of ≤ 5 ms, high system stability, and up to 12 channels per unit, the series replaces multiple standalone devices within a single platform. This significantly reduces investment costs, rack space requirements, and integration effort in test systems.

Key Benefits for the User

The architecture of the N61100 series provides targeted features for optimizing industrial test cycles in research, development, and quality assurance.

12CH
Maximum Integration Density
Up to 12 independent channels in just 3U enable significant rack space optimization in high-density test environments.
2R
Dual Measurement Ranges
Separate measurement ranges for voltage, current, resistance, and power improve accuracy across wide load ranges.
LED
Integrated LED Simulation
A software-configurable LED simulation replaces traditional load banks with precise models based on Rd and Vf.
500k
High-Speed Sampling
With a sampling rate of up to 500 kHz, waveforms and ripple effects can be analyzed directly within the device in great detail.
4W
Precise Remote Sensing
2-wire and 4-wire sensing compensate for voltage drops across the load cables and ensure accurate values directly at the DUT.
?
Comprehensive Protection Functions
OVP, OCP, OPP, OTP, and RV ensure maximum operational safety for both the system and the device under test.

Typical Application Areas

Thanks to its high flexibility and specialized operating modes, the N61100 series is suitable for a wide range of industrial test scenarios.

BAT
Battery Technology & Battery Simulation

Precise capacity tests and discharge testing for lithium-ion cells and storage systems under defined load conditions.

LED
Lighting Electronics

Validation of LED driver power supplies under realistic load conditions using a dedicated LED mode.

PSU
Multi-Channel Power Supplies

Simultaneous testing of PC power supplies, server power supplies, and industrial multi-rail systems.

AUTO
Automotive Electronics

Dynamic load testing for simulating real vehicle electrical system conditions and testing electronic control units.

ATE
Semiconductor Production

Used in ATE systems for high-throughput quality assurance in the consumer electronics and semiconductor industries.

Function and System Description

The control concept of the N61100 series combines classic standard operating modes with specialized hybrid modes to precisely map complex test requirements.

CC
Constant Current
Constant current operation for reproducible load testing of voltage sources and power supplies.
CV
Constant Voltage
Constant voltage mode for precise testing of voltage limits and control behavior.
CP
Constant Power
Constant power absorption for realistic simulation of power-controlled load profiles.
CR
Constant Resistance
Simulates resistive loads and is especially suitable for classic power supply and LED driver tests.
HYB
Combined Modes
CV+CC, CR+CC, CV+CR, and CP+CC enable flexible load profiles with automatic transitions between control modes.
OCP
Automated OCP Test
The load increases current step by step and automatically records the exact shutdown threshold of the overcurrent protection.

Special Functions and Operation

LED
LED Simulation

Simulation of an LED load based on an equivalent circuit with series resistance Rd and forward voltage Vf.

SZ
Impedance Simulation

Supports the emulation of special load characteristics and delivers valuable data for R&D applications.

RIP
Ripple Measurement

Detailed ripple and waveform analysis directly within the device, reducing the need for external measurement equipment in standard tests.

LCD
Local Operation

The high-resolution 4.3-inch LCD and numeric keypad allow convenient direct operation of the device.

Key Technical Data

Voltage Levels 80 V / 150 V / 600 V, depending on model
Current Up to 120 A, depending on model
Power Modular configurations from 150 W to 900 W
Accuracy For example, 0.025% + 0.025% F.S. in CV mode
Sampling Rate Up to 500 kHz
Communication LAN, RS232, and RS485 as standard
Response Time System-wide communication response ≤ 5 ms
Form Factor 19-inch rackmount, 3U

Variants and Configuration Options

The N61100 series is available in several configurations to provide the optimal balance between channel density and per-channel power.

Model Series Channels Power Focus
N61112 12 150 W per channel Maximum channel density for small loads
N61106 6 300 W per channel Universal use for medium loads
N61104 4 540 W per channel High power with a moderate number of channels
N61102 2 900 W per configuration Peak power for demanding individual tests

Maximum current and voltage values vary within the model series depending on the selected voltage level.

Integration and Automation

The N61100 series was consistently developed for Industry 4.0 environments and digitized test architectures, enabling seamless integration into existing ATE systems.

SCPI
Open Protocols
Modbus-RTU and SCPI enable direct integration into LabVIEW and custom test software.
SYNC
Synchronous Loading
Multiple channels can be operated synchronously, which is especially relevant for testing multi-channel power supplies.
TRIG
Trigger Interfaces
Dedicated trigger functions support precisely timed test sequences in synchronized ATE environments.
SEQ
Complex Test Sequences
A professional software suite supports remote control, sequence programming, and complete data logging.
ATE
Optimized for High Throughput
High communication speed and channel density increase efficiency and throughput in automated test lines.
RACK
Flexible Scalability
Test capacities can be flexibly adapted to growing requirements through the right model selection and compact multi-channel architecture.

Strategic Added Value for Industrial Users

The N61100 series offers high investment security thanks to its robust design, high integration density, and long-term scalability. Reducing rack space requirements and consolidating multiple functions in one device sustainably lowers the total cost of test infrastructure.

Users also benefit from local expertise, technical support, and project planning directly from Germany. This reduces downtime and supports fast, practical integration into existing test systems.

Consulting and Contact

Not sure whether this product is the best fit for your application? We are happy to support you in selecting the right solution for your requirements – from individual applications to complete system integration.

Contact us conveniently via live chat, the contact form, email, or phone – we provide personal and practical advice.

Depending on availability, we can also provide a free demo unit for evaluation in your test environment, allowing you to test the system directly under real conditions.

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly