Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N36620-80-08

Description
N36620-80-08 Programmable portable wide-range DC power supply, 200 W, 80 V, 8.2 A, compact benchtop design.
Current [A]
8
Power [P]
200
Voltage [V]
80
N36620-80-08
N36620-80-08 Programmable portable wide-range DC power supply, 200 W, 80 V, 8.2 A, compact benchtop design.
8
200
80
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36610-40-10

Description
N36610-40-10 Programmable portable wide-range DC power supply, 100 W, 40 V, 10 A, compact benchtop design.
Current [A]
10
Power [P]
100
Voltage [V]
40
N36610-40-10
N36610-40-10 Programmable portable wide-range DC power supply, 100 W, 40 V, 10 A, compact benchtop design.
10
100
40
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36620-40-16

Description
N36620-40-16 Programmable portable wide-range DC power supply, 200 W, 40 V, 16 A, compact benchtop design.
Current [A]
16
Power [P]
200
Voltage [V]
40
N36620-40-16
N36620-40-16 Programmable portable wide-range DC power supply, 200 W, 40 V, 16 A, compact benchtop design.
16
200
40
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36610-160-2.5

Description
N36610-160-2.5 Programmable portable wide-range DC power supply, 100 W, 160 V, 2.5 A, compact benchtop design.
Current [A]
2,5
Power [P]
100
Voltage [V]
160
N36610-160-2.5
N36610-160-2.5 Programmable portable wide-range DC power supply, 100 W, 160 V, 2.5 A, compact benchtop design.
2,5
100
160
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36620-160-04

Description
N36620-160-04 Programmable portable wide-range DC power supply, 200 W, 160 V, 4 A, compact benchtop design.
Current [A]
4
Power [P]
200
Voltage [V]
160
N36620-160-04
N36620-160-04 Programmable portable wide-range DC power supply, 200 W, 160 V, 4 A, compact benchtop design.
4
200
160
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36610-80-06

Description
N36610-80-06 Programmable portable wide-range DC power supply, 100 W, 80 V, 6 A, compact benchtop design.
Current [A]
6
Power [P]
100
Voltage [V]
80
N36610-80-06
N36610-80-06 Programmable portable wide-range DC power supply, 100 W, 80 V, 6 A, compact benchtop design.
6
100
80
Portable DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36600 overview: programmable DC power supply

The N36600 series comprises two single-channel DC power supplies for development, laboratory work, production aging and automated test systems. The N36610-80-06 provides 100 W and the N36620-80-08 provides 200 W. Both models offer a voltage range of 0.5 to 81 V, with current ranges up to 6.0 A and 8.2 A respectively. The available voltage and current combinations are determined by the power limit of each model.

Local operation uses buttons, a rotary knob and a VA display. Output power and elapsed output-on time can be displayed in addition to voltage and current. Stored voltage and current settings support recurring tasks. Separate sense connections enable regulation at the device under test, while LAN and serial interfaces provide remote control. The narrow enclosure suits individual workstations; an optional 4U chassis integrates multiple channels.

Key benefits

More operating points per instrument

The wide-range characteristic supports higher voltages at lower currents and higher currents at lower voltages, within the 100 W or 200 W power rating.

Fine setpoint adjustments

Voltage resolution of 10 mV and current resolution of 1 mA apply to both setting and readback, supporting targeted adjustments at the test station.

Recall recurring settings

Four shortcut memories per group and 100 groups store voltage and current values. Frequently used operating points can be recalled directly.

Measure voltage at the DUT

Four-wire sense accounts for cable losses in voltage regulation and supports setups where the instrument and device under test are separated.

More stable measurement readings

Selectable voltage and current measurement filters with moving or exponential averaging make fluctuating values easier to read.

Record measurement trends

The PC application software displays voltage, current, power and time, and can save measurement data for subsequent evaluation.

Operating principle and wide-range characteristic

In constant voltage (CV) mode, the instrument regulates its output voltage to the setpoint. When load current reaches the configured current limit, it automatically switches to constant current (CC) mode and adjusts output voltage to the load. Once current falls below the limit, the supply returns to CV mode.

Available power also limits the operating point: P = U × I. Within the permissible voltage range, I ≤ min(maximum current, maximum power/U). At 80 V, the calculated current limit is 1.25 A for the 100 W model and 2.5 A for the 200 W model. Maximum voltage and maximum current are therefore not available simultaneously.

Models and output ranges

ModelVoltage rangeCurrent rangeOutput powerChannels
N36610-80-060.5–81 V0–6.0 A100 W1
N36620-80-080.5–81 V0–8.2 A200 W1

All values apply to one instrument. Model selection must account for voltage, current and power at the actual operating point.

Resolution, ripple and dynamic response

ParameterN36610-80-06N36620-80-08
Voltage setting and readback resolution10 mV10 mV
Current setting and readback resolution1 mA1 mA
Voltage ripple and noise, 20 Hz–20 MHz≤10 mV RMS≤10 mV RMS
Current ripple and noise, 20 Hz–20 MHz≤8 mA RMS≤8 mA RMS
Voltage rise time, no load / full load≤300 ms / ≤300 ms≤300 ms / ≤300 ms
Voltage fall time, no load / full load≤500 ms / ≤200 ms≤500 ms / ≤300 ms
Voltage load regulation≤20 mV≤30 mV
Current load regulation≤10 mA≤10 mA

Resolution and accuracy are different parameters. Selectable measurement averaging stabilizes the display; it does not change the stated resolutions.

Operation and programmable functions

FunctionOperation and benefit
Shortcut memories100 groups, each containing four stored voltage and current settings, for recurring operating points.
Measurement filtersVoltage and current filters can be enabled separately; exponential or moving averaging with a factor or sample count from 1 to 64.
Trigger selectionChoose key, rear-panel TTL or communication triggering; a further mode accepts only TRIGger:IMMediate.
Display and keypad lockSwitch between voltage/current and time/power displays; keypad locking helps prevent unintended changes.
Output controlSwitch the output using the On/Off button; measured voltage and current are displayed while the output is enabled.

Typical applications

Development and laboratory work

Power electronic devices under test at different operating points. CV/CC regulation, fine resolution and shortcut memories support recurring laboratory tasks.

Production aging tests

Supply devices under test with defined DC settings during production aging. The PC software can record voltage, current and power trends.

Automated test stations

Integrate DC power into ATE systems. Remote control, external triggering and the optional multi-channel chassis support setups with several test channels.

Interfaces, software and system integration

EquipmentClassificationFunction
LANIntegrated interfaceNetwork connectivity and operation with the PC application software.
RS232 / RS485Integrated interfacesSerial instrument communication for remote control.
SCPI / Modbus-RTUSupported protocolsProtocol selection in the instrument menu; match communication settings to the controller.
RS485/TRIGRear-panel connectionRS485 communication and external TTL trigger input.
PC application softwareInstrument control softwareSet parameters, display readings and graphs, and save recordings in .ndat format.
4U chassisOptionIntegration of up to eight DC power supply channels.

The optional chassis provides multi-channel integration. Model ratings still apply to each instrument; housing several units together does not combine their power at a single output channel.

Installation and infrastructure

ParameterSpecification
AC inputSingle-phase, 100–240 V AC, 47–63 Hz
Dimensions W × D × H55 × 315 × 140 mm
Net weightApproximately 1.8 kg
Operating environment0–40 °C; relative humidity ≤80%, non-condensing
Storage−10–70 °C; relative humidity ≤70%, non-condensing
Cooling and connectionKeep fan openings unobstructed and ensure a reliable protective earth connection.

Select load cables for the required current, voltage and cable length. Keep sense leads short and twisted, and route them separately from the AC power cable.

Protection functions

Overvoltage and overcurrent protection (OVP/OCP) have adjustable thresholds. When protection is enabled, a trip switches the output off. Protection is enabled through the P_ON setting. Overtemperature protection (OTP) is also provided. An OCP shutdown and normal CC regulation serve different purposes: CC limits operating current, whereas OCP triggers a protective shutdown.

Frequently asked questions about the N36600

Are 81 V and 8.2 A available simultaneously?

No. The N36620-80-08 has a 200 W output limit that constrains the voltage and current combination. The corresponding limit for the N36610-80-06 is 100 W.

How do the two models differ?

The N36610-80-06 provides up to 100 W and 6.0 A; the N36620-80-08 provides up to 200 W and 8.2 A. Both offer 0.5–81 V with power-dependent output current.

What is four-wire sense used for?

Voltage is measured directly at the device under test, allowing the regulator to account for voltage drops along the load cables.

How many settings can be stored?

There are 100 groups, each with four shortcut memories for voltage and current settings.

What does the optional 4U chassis provide?

It accommodates up to eight DC power supply channels. Each channel remains within the power, voltage and current limits of its instrument.

Is the N36600 suitable for laboratory development?

Yes. Adjustable DC output, CV/CC switching and stored operating points support laboratory tests on electronic devices.

Can it power devices during production aging tests?

Yes. Production aging is an intended application. The PC software supports recording electrical measurements during operation.

Can the N36600 be integrated into ATE systems?

Yes. LAN, RS232, RS485 and an external trigger support integration. The optional chassis is available for multiple power supply channels.

Technical consultation for the N36600

Tell us the voltage and current required at your operating point, the channel count, your interface and the planned installation. We can help you choose between 100 W and 200 W and discuss sense connections, automation and the optional chassis.

Discuss your N36600 application with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly