Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
N36150-20-100

Description
N36150-20-100 Programmable wide-range DC power supply, 500 W, 20 V, 100 A, 1U, LAN/RS232/RS485/CAN
Current [A]
100
Power [P]
500
Voltage [V]
20
N36150-20-100
N36150-20-100 Programmable wide-range DC power supply, 500 W, 20 V, 100 A, 1U, LAN/RS232/RS485/CAN
100
500
20
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36150-40-50

Description
N36150-40-50 Programmable wide-range DC power supply, 500 W, 40 V, 50 A, 1U, LAN/RS232/RS485/CAN
Current [A]
50
Power [P]
500
Voltage [V]
40
N36150-40-50
N36150-40-50 Programmable wide-range DC power supply, 500 W, 40 V, 50 A, 1U, LAN/RS232/RS485/CAN
50
500
40
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36150-80-25

Description
N36150-80-25 Programmable wide-range DC power supply, 500 W, 80 V, 25 A, 1U, LAN/RS232/RS485/CAN
Current [A]
25
Power [P]
500
Voltage [V]
80
N36150-80-25
N36150-80-25 Programmable wide-range DC power supply, 500 W, 80 V, 25 A, 1U, LAN/RS232/RS485/CAN
25
500
80
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36150-150-12

Description
N36150-150-12 Programmable wide-range DC power supply, 500 W, 150 V, 12 A, 1U, LAN/RS232/RS485/CAN
Current [A]
12
Power [P]
500
Voltage [V]
150
N36150-150-12
N36150-150-12 Programmable wide-range DC power supply, 500 W, 150 V, 12 A, 1U, LAN/RS232/RS485/CAN
12
500
150
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36150-300-8

Description
N36150-300-8 Programmable wide-range DC power supply, 500 W, 300 V, 8 A, 1U, LAN/RS232/RS485/CAN
Current [A]
8
Power [P]
500
Voltage [V]
300
N36150-300-8
N36150-300-8 Programmable wide-range DC power supply, 500 W, 300 V, 8 A, 1U, LAN/RS232/RS485/CAN
8
500
300
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36190-20-100

Description
N36190-20-100 Programmable wide-range DC power supply, 900 W, 20 V, 100 A, 1U, LAN/RS232/RS485/CAN
Current [A]
100
Power [P]
900
Voltage [V]
20
N36190-20-100
N36190-20-100 Programmable wide-range DC power supply, 900 W, 20 V, 100 A, 1U, LAN/RS232/RS485/CAN
100
900
20
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36190-40-50

Description
N36190-40-50 Programmable wide-range DC power supply, 900 W, 40 V, 50 A, 1U, LAN/RS232/RS485/CAN
Current [A]
50
Power [P]
900
Voltage [V]
40
N36190-40-50
N36190-40-50 Programmable wide-range DC power supply, 900 W, 40 V, 50 A, 1U, LAN/RS232/RS485/CAN
50
900
40
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36190-80-25

Description
N36190-80-25 Programmable wide-range DC power supply, 900 W, 80 V, 25 A, 1U, LAN/RS232/RS485/CAN
Current [A]
25
Power [P]
900
Voltage [V]
80
N36190-80-25
N36190-80-25 Programmable wide-range DC power supply, 900 W, 80 V, 25 A, 1U, LAN/RS232/RS485/CAN
25
900
80
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36190-150-12

Description
N36190-150-12 Programmable wide-range DC power supply, 900 W, 150 V, 12 A, 1U, LAN/RS232/RS485/CAN
Current [A]
12
Power [P]
900
Voltage [V]
150
N36190-150-12
N36190-150-12 Programmable wide-range DC power supply, 900 W, 150 V, 12 A, 1U, LAN/RS232/RS485/CAN
12
900
150
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36190-300-8

Description
N36190-300-8 Programmable wide-range DC power supply, 900 W, 300 V, 8 A, 1U, LAN/RS232/RS485/CAN
Current [A]
8
Power [P]
900
Voltage [V]
300
N36190-300-8
N36190-300-8 Programmable wide-range DC power supply, 900 W, 300 V, 8 A, 1U, LAN/RS232/RS485/CAN
8
900
300
Autoranging DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Benchtop Unit

N36100 programmable DC power supply overview

The N36100 series is a single-channel programmable DC power supply for development, laboratory work and automated test systems. The N36150 and N36190 ranges provide 500 W and 900 W respectively. Each power class offers five versions with maximum voltages of 20 V, 40 V, 80 V, 150 V or 300 V; the corresponding current limits range from 8 A to 100 A. Voltage, current and power jointly define the available operating point.

Operation is available through the OLED display, function keys and rotary control, or via the digital interfaces. In addition to conventional voltage regulation with current limiting, the series offers constant power operation, test sequences and simple internal resistance simulation. Remote sense measures voltage directly at the DUT. With a height of 43 mm and a width of 214 mm, the enclosure supports compact benchtop setups and the integration of multiple devices into a test station.

Key benefits

Compact integration

Up to 900 W in a 1U, half 19-inch enclosure reduces the space required for DC power in the laboratory and test rack.

Regulation priority matched to the load

Selectable voltage or current priority helps reduce startup overshoot of the parameter that is critical to the DUT.

Measure voltage at the DUT

Four-wire sensing compensates for voltage drops in the load leads up to the permitted sense limit of 2 V.

Repeat test profiles

Stored sequences execute defined voltage and current settings with dwell times, reducing manual adjustments during testing.

Reproduce source behaviour

A preset internal resistance produces a current-dependent voltage drop, enabling simple simulation of non-ideal DC sources.

Remote control and recording

Digital interfaces and PC software combine instrument control with measurement display and recording to support traceable test procedures.

Operating principle and regulation

In CV mode, the source maintains the set voltage until the current limit is reached. In CC mode, it regulates current and adjusts the output voltage to the load. CP mode adjusts voltage or current to maintain the set output power within the permitted limits.

CV/CC priority determines how the output is established. CV priority is suitable, for example, for powering sensitive low-voltage processors or FPGA cores. CC priority is intended for low-impedance loads such as batteries during charging or circuits with large capacitances. Priority should match the load because a subsequent transition between CV and CC can cause overshoot.

Models and available power range

ModelVoltage rangeCurrent rangeRated powerChannels
N36150-20-1000–20 V0–100 A500 W1
N36150-40-500–40 V0–50 A500 W1
N36150-80-250–80 V0–25 A500 W1
N36150-150-140–150 V0–12 A500 W1
N36150-300-80–300 V0–8 A500 W1
N36190-20-1000–20 V0–100 A900 W1
N36190-40-500–40 V0–50 A900 W1
N36190-80-250–80 V0–25 A900 W1
N36190-150-120–150 V0–12 A900 W1
N36190-300-80–300 V0–8 A900 W1

The maximum voltage and current values are not available simultaneously when their product exceeds the rated power. Within the permitted operating envelope, for U > 0: I_max = min(I_rated, P_rated/U).

N36190-20-100 example: At 20 V, the 900 W power limit allows a maximum of 45 A. An output current of 100 A is available at voltages up to 9 V.

Dynamic response and regulation

ParameterValue and condition
Transient recovery time≤1 ms for a 10–90% load change; recovery to within 0.5% of the rated output voltage.
No-load voltage rise time≤100 ms for 10–90% of full scale.
Line and load regulationVoltage ≤0.05% each; current ≤0.1% each.
Programming response time≤10 ms; distinct from electrical rise and recovery times.

Loaded rise and fall times depend on the selected model. Dynamic test profiles therefore require consideration of load behaviour, regulation priority and the DUT timing requirements in addition to the programmed values.

Operating modes and programmable functions

FunctionOperation and benefit
V/I and CPVoltage regulation with current limiting or constant power operation for different power supply tasks.
SEQUp to 20 sequence files and 1,000 steps in total. Voltage, current, dwell time, voltage rise time and current rise time can be set for each step. Repetitions and file linking support multi-stage procedures.
Internal resistance simulationAdjustable source voltage and internal resistance; output voltage decreases with increasing output current according to the selected resistance.
Auto RunAutomatic output activation after instrument startup with an adjustable delay.
Remote senseVoltage measurement at the DUT through separate sense leads; maximum compensated voltage drop of 2 V.

Typical applications

Laboratory electronics development

Power circuits at adjustable DC operating points. CV/CC priority helps adapt startup behaviour to sensitive or low-impedance DUTs.

Automotive electronics testing

Power vehicle components with programmed voltage and current profiles. SEQ reproduces repeatable supply changes, such as starting conditions, within the instrument and dynamic limits.

Production and ATE test systems

Integrate DC power into automated production test stations. Digital remote control and stored sequences support defined DUT supply conditions.

Industrial DC/DC converters

Provide an adjustable input voltage for converter testing. The wide-range output and current limiting accommodate different input operating points within the rated power.

Powering avionics components

Programmable DC power for avionics test setups. Setpoints and regulation priority can be matched to the electrical requirements of the component.

Small DC motors

Power small motors with adjustable voltage and current limiting. Inductive loads require suitable external protection against voltage spikes and back EMF.

Interfaces, software and automation

EquipmentAvailabilityFunction
LANStandardRemote control over Ethernet using UDP communication.
RS232StandardSerial remote control with adjustable baud rate.
RS485 and CANStandardBus connectivity; CANopen with configurable CAN ID and baud rate.
APG / PROG interfaceOptionalAnalogue voltage programming: a 0–5 V input signal corresponds to 0–100% output voltage. Only the voltage setpoint is programmed through this analogue function.
PC application softwareWindows applicationControl of normal, CP and sequence modes, display of readings and charts, data recording and access to historical measurements.

Multiple devices can be controlled together from a PC over LAN. Each device requires a unique IP address. This allows multiple separately powered test channels to be operated within a shared control environment.

Installation and infrastructure

ParameterSpecification
AC inputSingle-phase, 220 V AC ±10%, 47–63 Hz.
Dimensions and weight43 × 214 × 420 mm (H × W × D), 1U, approximately 4 kg.
EnvironmentOperation 0–40 °C; storage −20–60 °C; relative humidity 5–90%, non-condensing; altitude <2,000 m.
Cooling and installationKeep ventilation openings clear and account for airflow in the test rack.
Load and sense leadsSize load leads for current, voltage and cable length. Route sense leads separately from the AC input cable.

Protection functions

Overvoltage protection (OVP), overcurrent protection (OCP) and overpower protection (OPP) use adjustable thresholds. If a threshold is exceeded, the output switches off and the instrument displays the protection message. Overtemperature protection (OTP) uses a fixed threshold and disables the output if the internal temperature becomes too high. Short-circuit protection is also provided.

Current limiting during normal CC operation is distinct from the OCP shutdown function. For inductive DUTs, external protection must be matched to the voltage transients and energy flow involved.

Frequently asked questions about the N36100 series

Are 300 V and 100 A available simultaneously?

No. These values belong to different models. In addition, the 500 W or 900 W rated power limits the combination of voltage and current available at the same operating point.

When should CV or CC priority be selected?

CV priority supports controlled voltage startup at sensitive voltage inputs. CC priority is intended for low-impedance loads, battery charging or large input capacitances.

How extensive can sequences be?

Up to 20 sequence files and 1,000 steps in total are available. Voltage, current and dwell time can be set for each step; repetitions and file linking extend the procedure.

What does remote sense compensate for?

Remote sense measures voltage at the DUT and compensates for the voltage drop in the load leads. The maximum compensated voltage drop is 2 V.

What does the optional analogue control provide?

A 0–5 V input signal sets the output voltage from zero to full scale. An analogue current setpoint is not supported by this function.

Can supply profiles for automotive electronics be created?

Yes. SEQ outputs defined voltage and current profiles, for example for tests involving starting conditions. The profile must remain within the electrical and dynamic limits of the selected model.

Can the series be used in ATE and production test stations?

Yes. Digital remote control, repeatable sequences and the compact enclosure support integration as a DC source. Multiple devices can be controlled from a PC using unique IP addresses.

Can the N36100 power industrial DC/DC converters?

Yes. It provides the adjustable DC input supply for converter testing. Model selection must account for input voltage, required current and power at the same operating point.

Technical consultation for the N36100 series

Selecting the right model depends on voltage and current at the actual operating point, required power, load behaviour and test profiles. Please also tell us your interface requirements, any need for analogue control and the available installation space.

Discuss your project requirements with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly