Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
LAB/HP 315

Description
LAB/HP 315 DC high-power source, 3 kW, 15 V, 250 A, M/S connectable, Made in Germany
Current [A]
250
Power [P]
3000
Voltage [V]
15
LAB/HP 315
LAB/HP 315 DC high-power source, 3 kW, 15 V, 250 A, M/S connectable, Made in Germany
250
3000
15
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 320

Description
LAB/HP 320 DC high-power source, 3 kW, 20 V, 250 A, M/S connectable, Made in Germany
Current [A]
250
Power [P]
3000
Voltage [V]
20
LAB/HP 320
LAB/HP 320 DC high-power source, 3 kW, 20 V, 250 A, M/S connectable, Made in Germany
250
3000
20
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 325

Description
LAB/HP 325 DC high-power source, 3 kW, 25 V, 240 A, M/S connectable, Made in Germany
Current [A]
240
Power [P]
3000
Voltage [V]
25
LAB/HP 325
LAB/HP 325 DC high-power source, 3 kW, 25 V, 240 A, M/S connectable, Made in Germany
240
3000
25
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 330

Description
LAB/HP 330 DC high-power source, 3 kW, 30 V, 234 A, M/S connectable, Made in Germany
Current [A]
234
Power [P]
3000
Voltage [V]
30
LAB/HP 330
LAB/HP 330 DC high-power source, 3 kW, 30 V, 234 A, M/S connectable, Made in Germany
234
3000
30
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 335

Description
LAB/HP 335 DC high-power source, 3 kW, 35 V, 200 A, M/S connectable, Made in Germany
Current [A]
200
Power [P]
3000
Voltage [V]
35
LAB/HP 335
LAB/HP 335 DC high-power source, 3 kW, 35 V, 200 A, M/S connectable, Made in Germany
200
3000
35
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 340

Description
LAB/HP 340 DC high-power source, 3 kW, 40 V, 175 A, M/S connectable, Made in Germany
Current [A]
175
Power [P]
3000
Voltage [V]
40
LAB/HP 340
LAB/HP 340 DC high-power source, 3 kW, 40 V, 175 A, M/S connectable, Made in Germany
175
3000
40
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 345

Description
LAB/HP 345 DC high-power source, 3 kW, 45 V, 156 A, M/S connectable, Made in Germany
Current [A]
156
Power [P]
3000
Voltage [V]
45
LAB/HP 345
LAB/HP 345 DC high-power source, 3 kW, 45 V, 156 A, M/S connectable, Made in Germany
156
3000
45
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 350

Description
LAB/HP 350 DC high-power source, 3 kW, 50 V, 140 A, M/S connectable, Made in Germany
Current [A]
140
Power [P]
3000
Voltage [V]
50
LAB/HP 350
LAB/HP 350 DC high-power source, 3 kW, 50 V, 140 A, M/S connectable, Made in Germany
140
3000
50
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 360

Description
LAB/HP 360 DC high-power source, 3 kW, 60 V, 117 A, M/S connectable, Made in Germany
Current [A]
117
Power [P]
3000
Voltage [V]
60
LAB/HP 360
LAB/HP 360 DC high-power source, 3 kW, 60 V, 117 A, M/S connectable, Made in Germany
117
3000
60
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 370

Description
LAB/HP 370 DC high-power source, 3 kW, 70 V, 100 A, M/S connectable, Made in Germany
Current [A]
100
Power [P]
3000
Voltage [V]
70
LAB/HP 370
LAB/HP 370 DC high-power source, 3 kW, 70 V, 100 A, M/S connectable, Made in Germany
100
3000
70
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 380

Description
LAB/HP 380 DC high-power source, 3 kW, 80 V, 88 A, M/S connectable, Made in Germany
Current [A]
88
Power [P]
3000
Voltage [V]
80
LAB/HP 380
LAB/HP 380 DC high-power source, 3 kW, 80 V, 88 A, M/S connectable, Made in Germany
88
3000
80
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 3100

Description
LAB/HP 3100 DC high-power source, 3 kW, 100 V, 70 A, M/S connectable, Made in Germany
Current [A]
70
Power [P]
3000
Voltage [V]
100
LAB/HP 3100
LAB/HP 3100 DC high-power source, 3 kW, 100 V, 70 A, M/S connectable, Made in Germany
70
3000
100
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 3150

Description
LAB/HP 3150 DC high-power source, 3 kW, 150 V, 47 A, M/S connectable, Made in Germany
Current [A]
47
Power [P]
3000
Voltage [V]
150
LAB/HP 3150
LAB/HP 3150 DC high-power source, 3 kW, 150 V, 47 A, M/S connectable, Made in Germany
47
3000
150
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 3300

Description
LAB/HP 3300 DC high-power source, 3 kW, 300 V, 24 A, M/S connectable, Made in Germany
Current [A]
24
Power [P]
3000
Voltage [V]
300
LAB/HP 3300
LAB/HP 3300 DC high-power source, 3 kW, 300 V, 24 A, M/S connectable, Made in Germany
24
3000
300
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 3600

Description
LAB/HP 3600 DC high-power source, 3 kW, 600 V, 12 A, M/S connectable, Made in Germany
Current [A]
12
Power [P]
3000
Voltage [V]
600
LAB/HP 3600
LAB/HP 3600 DC high-power source, 3 kW, 600 V, 12 A, M/S connectable, Made in Germany
12
3000
600
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 3800

Description
LAB/HP 3800 DC high-power source, 3 kW, 800 V, 9 A, M/S connectable, Made in Germany
Current [A]
9
Power [P]
3000
Voltage [V]
800
LAB/HP 3800
LAB/HP 3800 DC high-power source, 3 kW, 800 V, 9 A, M/S connectable, Made in Germany
9
3000
800
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 31000

Description
LAB/HP 31000 DC high-power source, 3 kW, 1000 V, 7 A, M/S connectable, Made in Germany
Current [A]
7
Power [P]
3000
Voltage [V]
1000
LAB/HP 31000
LAB/HP 31000 DC high-power source, 3 kW, 1000 V, 7 A, M/S connectable, Made in Germany
7
3000
1000
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 31200

Description
LAB/HP 31200 DC high-power source, 3 kW, 1200 V, 5.8 A, M/S connectable, Made in Germany
Current [A]
5,8
Power [P]
3000
Voltage [V]
1200
LAB/HP 31200
LAB/HP 31200 DC high-power source, 3 kW, 1200 V, 5.8 A, M/S connectable, Made in Germany
5,8
3000
1200
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 31500

Description
LAB/HP 31500 DC high-power source, 3 kW, 1500 V, 4.7 A, M/S connectable, Made in Germany
Current [A]
4,7
Power [P]
3000
Voltage [V]
1500
LAB/HP 31500
LAB/HP 31500 DC high-power source, 3 kW, 1500 V, 4.7 A, M/S connectable, Made in Germany
4,7
3000
1500
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 415

Description
LAB/HP 415 DC high-power source, 4 kW, 15 V, 500 A, M/S connectable, Made in Germany
Current [A]
500
Power [P]
4000
Voltage [V]
15
LAB/HP 415
LAB/HP 415 DC high-power source, 4 kW, 15 V, 500 A, M/S connectable, Made in Germany
500
4000
15
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 420

Description
LAB/HP 420 DC high-power source, 4 kW, 20 V, 250 A, M/S connectable, Made in Germany
Current [A]
250
Power [P]
4000
Voltage [V]
20
LAB/HP 420
LAB/HP 420 DC high-power source, 4 kW, 20 V, 250 A, M/S connectable, Made in Germany
250
4000
20
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 425

Description
LAB/HP 425 DC high-power source, 4 kW, 25 V, 240 A, M/S connectable, Made in Germany
Current [A]
240
Power [P]
4000
Voltage [V]
25
LAB/HP 425
LAB/HP 425 DC high-power source, 4 kW, 25 V, 240 A, M/S connectable, Made in Germany
240
4000
25
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 430

Description
LAB/HP 430 DC high-power source, 4 kW, 30 V, 234 A, M/S connectable, Made in Germany
Current [A]
234
Power [P]
4000
Voltage [V]
30
LAB/HP 430
LAB/HP 430 DC high-power source, 4 kW, 30 V, 234 A, M/S connectable, Made in Germany
234
4000
30
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

LAB/HP 435

Description
LAB/HP 435 DC high-power source, 4 kW, 35 V, 200 A, M/S connectable, Made in Germany
Current [A]
200
Power [P]
4000
Voltage [V]
35
LAB/HP 435
LAB/HP 435 DC high-power source, 4 kW, 35 V, 200 A, M/S connectable, Made in Germany
200
4000
35
High Power DC Source

Technical Data

Product category

DC Power Supply

Type of DC source

Standard DC Source

Mehr laden...

LAB/HP programmable DC power supply overview

The LAB/HP series is a microcontroller-controlled high-power DC source for laboratories, development and automated test systems. It covers power classes from 3 to 63 kW, voltage variants up to 1,500 V and current variants up to 2,250 A. A 2,000 V version is available as an option after the application has been reviewed. Depending on power and current class, the modular 19-inch design ranges from 2U to 9U; up to 21 kW is available in 3U.

The TFT touch display presents setpoints and measured values for voltage, current, power and load resistance. In addition to conventional voltage/current control, the unit offers power limiting, internal-resistance emulation, PV characteristic simulation and freely programmable characteristics. For test-system integration, the standard version includes a galvanically isolated ATI 5/10 analogue interface, RS232, LAN, soft interlock and ETS-bus master/slave. The reduced-function LAB/HP/E version omits master/slave, soft interlock, UIP, UIR and PVSim, among other features.

Key benefits

Broad power scaling

Thirteen power classes from 3 to 63 kW and numerous voltage/current combinations support precise adaptation to the operating point.

High power density

Up to 21 kW fits into a 3U 19-inch enclosure; very high-current low-voltage versions may require more rack space.

Programmable characteristics

PVSim and User mode reproduce PV or freely defined V/I characteristics for repeatable operating points and curve profiles.

Autonomous sequences

Scripts of up to 1,000 commands control setpoints, delays, loops and output states directly from the storage medium.

Compensate cable drop

Remote sense compensates voltage drops up to 10 percent of rated output voltage within the permissible characteristic.

Flexible system topologies

Up to eight units can be coordinated through the ETS bus for parallel, series or electrically independent outputs.

Operating principle and control

A microcontroller generates the commands for the analogue power regulator. In UI mode, voltage and current setpoints are passed directly to the switch-mode regulator. In UIP mode, an additional digital controller limits output power. UIR calculates the voltage setpoint from output current and the selected internal resistance according to Vtarget = Vset - Iout × Ri, thereby emulating a source with internal resistance.

PVSim uses open-circuit voltage, short-circuit current, and voltage and current at the maximum power point. User-defined characteristics can store support points and run them as stepped or linearly interpolated curves. Current and voltage rise ramps can be limited separately when leaving standby.

Power range and unit selection

The following classes cover the complete standard power range in the data sheet. The voltages are example variants; other voltages are planned from a quantity of one. Current rating, voltage rating and nominal power must be considered together: usable current at the operating point is limited by both the current rating and the power limit.

Nominal powerBasic enclosureExample voltage rangeHighest current rating in matrix
3 kW2U15-1,500 V250 A
4 kW2U15-1,500 V500 A
5 kW2U15-1,500 V500 A
7 kW2U15-1,500 V500 A
10 kW3U15-1,500 V666 A
15 kW3U15-1,500 V1,000 A
21 kW3U20-1,500 V1,250 A
30 kW6U20-1,500 V1,500 A
35 kW6U20-1,500 V1,750 A
45 kW6U20-1,500 V2,250 A
49 kW9U25-1,500 V2,000 A
56 kW9U25-1,500 V2,250 A
63 kW9U30-1,500 V2,100 A

Selection note: Some low-voltage, high-current variants differ from the basic enclosure, including 15 kW at 15 V and 21 kW at 20 or 25 V. The exact height, depth, mains version and terminal arrangement must therefore be defined for the selected configuration.

Operating modes and programmable functions

FunctionOperationPurpose
UIDirect voltage and current limitingConventional constant-voltage or constant-current operation
UIPUI control with an additional power limitRestricts the operating point to a defined maximum output power
UIRVoltage control with adjustable simulated internal resistanceEmulates the behavior of a non-ideal voltage source
PVSimPV characteristic using VOC, ISC, VMPP and IMPPProvides defined operating points of a photovoltaic source
User characteristicStepped or linearly interpolated V/I support pointsCreates application-specific output characteristics
ScriptUp to 1,000 commands with delays, loops and WAITAutomates repeatable sequences directly on the unit
t-EnableTime-limited operation after startReturns the source to standby after the specified duration
V-Slope / I-SlopeSeparately adjustable voltage and current rampLimits setpoint change when leaving standby

Dynamics, stability and measured values

Depending on voltage class, full-load rise times range from 6 to 40 ms and full-load fall times from 15 to 100 ms. For the 1,401 to 1,500 V class, the specified values are 6 ms rise time and 25 ms fall time. After dynamic load changes, output voltage returns within 0.5 percent of rated output plus/minus 25 mV in less than 3 ms.

CharacteristicSpecification
Static regulationplus/minus 0.1% of full scale
Voltage/current stability during line variationplus/minus 0.02% of full scale in each case
Voltage stability during load variationplus/minus 0.05% of full scale plus/minus 20 mV
Current stability during load variationplus/minus 0.05% of full scale plus/minus 20 mA
Voltage / current setpoint accuracy0.1% / 0.2%
Analogue interfaceSetpoint accuracy with internal reference plus/minus 0.5%; response time < 10 ms
High-speed optionReduced output capacitance; rise and fall times shortened by an average factor of 10

Typical applications

Automated test sequences

Digital remote control, scripts and optional data logging support repeatable routines up to a self-contained test station.

Varistor testing

t-Enable limits active output time and automatically returns the source to standby afterwards.

Motor starting and inductive loads

Timed operation supports examination of motor-starting processes; the optional freewheeling diode protects against negative induced voltage.

Laser-diode testing

Adjustable voltage and current rise ramps limit the rate of change when the output is enabled.

Battery-coupled supply

The optional series decoupling diode prevents unwanted feedback and simplifies connection of the source to a battery.

Interfaces and automation

EquipmentStatusFunction
ATI 5/10Standard LAB/HPGalvanically isolated 0-5 V / 0-10 V analogue interface for V, I, P and OVP, monitor values, status and soft interlock
RS232 and LANStandard LAB/HPDigital remote control; LAN supports browser monitoring and operation as well as control through port 10001
IEEE 488, RS485, USBOptionsAdditional digital interfaces; a maximum of three digital interfaces in total
USB port / storage mediumStandard LAB/HPLoads and manages scripts and user-defined characteristics
Data loggerOptionSaves measured values to the storage medium at adjustable intervals
Remote senseUnit functionCompensates voltage drop between the output and load
Leadless remote sensingOptionSimulates a negative internal resistance and corrects cable drop as a function of output current

ETS bus, parallel and series operation

Up to eight LAB/HP units can be connected through the ETS bus. The USB Type-A cables are used exclusively as bus cables and must not be connected to a USB interface. There is no permanently assigned master unit: setpoints are forwarded from the unit currently being operated to all participants.

In parallel mode, the system displays total current; in series mode, it displays total voltage. Distribution between individual units is not necessarily symmetrical. In independent mode, the outputs remain electrically separate and exchange only setpoints through the bus. A maximum of 2,000 V is specified for series connection. Master/slave cannot be combined with operation from the storage medium.

Protection functions and options

FunctionEffect
OVP, UVP, OCP, OTPMonitor overvoltage, undervoltage, overcurrent and heat-sink temperature; UVP and OCP have adjustable delays.
FoldbackSwitches off the output after 10 ms to 10 s when the selected CV, CC or CP limit is reached.
FDOptional freewheeling diode for negative induced voltage from motors and inductive loads.
DDSOptional series decoupling diode against feedback and overvoltage up to 150% of maximum output voltage.
POP / AOPOptional passive suppression of voltage peaks or active absorption of longer-lasting overvoltage by an internal load.
PROptional polarity reversal exclusively in de-energized standby.
Pulsed outputOptional periodic switch-off at 2-500 Hz and 1 to 4,000,000 pulses or continuous oscillation; digital control only.
EMOOptional emergency shutdown that actively short-circuits the DC output after mains switch-off and reduces it below 60 V within 10 s.

Installation and environmental conditions

CharacteristicConfiguration / requirement
Mains versions1 × 230 VAC for 3-5 kW; three-phase 200, 208, 400, 440 or 480 VAC depending on version; 47-63 Hz
Typical efficiency94%
CoolingTemperature-controlled fans; maximum airflow 310 m³/h per 7.5 kW module
Operating temperature0 to 50 °C
Storage / humidity / altitude-20 to 70 °C / < 80% / < 2,000 m
Ingress protectionIP20; overvoltage category II; pollution degree II
Dimensions19-inch, 2U to 9U, 440 to 620 mm deep depending on configuration; individual high-current versions differ
Specified standardsEN 61010-1:2010, EN 61326-1:2013 and EN IEC 63000:2018

The protective conductor, mains cable, external overcurrent protection, DC cables and ventilation must be sized for the selected power class. Heated exhaust air must be safely removed when the unit is installed in a rack.

LAB/HP series FAQ

How is the appropriate LAB/HP version selected?

All required voltage/current operating points, nominal power, enclosure height, mains version, interfaces and options are decisive. Particularly high currents may require a larger enclosure.

Can maximum voltage and maximum current be used simultaneously?

Only within the nominal power of the selected unit. Both current rating and power limit restrict the operating point, so V, I and P must be checked together.

What is the difference between LAB/HP and LAB/HP/E?

LAB/HP/E is the reduced-function version. Master/slave, soft interlock, and UIP, UIR and PVSim modes are not available.

Which interfaces are available?

The standard LAB/HP includes ATI 5/10, RS232 and LAN. IEEE 488, RS485 and USB are optional digital interfaces; up to three digital interfaces are possible.

How much cable drop can remote sense compensate?

Within the output characteristic, it can compensate a maximum of 10 percent of maximum output voltage. Sense leads must never carry load current.

Can the LAB/HP simulate a PV source?

Yes. PVSim uses open-circuit voltage, short-circuit current and the MPP operating point to reproduce the characteristic of a PV generator.

Can test sequences run without an active PC?

Yes. Scripts containing up to 1,000 commands can be loaded from the storage medium and started automatically. Data logging is a separate option.

Is the source suitable for motor-start testing?

Yes. t-Enable provides time-limited power for examining motor-starting processes. The optional freewheeling diode is provided for induced reverse voltage.

How does the LAB/HP support laser-diode testing?

Separately adjustable V-Slope and I-Slope functions limit the voltage or current rise when the output is enabled.

Technical consultation and project enquiry

To configure the unit, we need the required voltage, current and power operating points, the available mains supply and rack space. Please also specify the desired interfaces, control modes, dynamics, protection options and requirements for sense or multi-unit operation.

Discuss your LAB/HP project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly