Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
KGS 15

Description
KGS SiC AC/DC source and load, 15 kVA, AC 450 V L-N, DC 636 V, 70 A, DC–5 kHz
Current [A]
70
Power [P]
15000
Voltage [V]
450
KGS 15
KGS SiC AC/DC source and load, 15 kVA, AC 450 V L-N, DC 636 V, 70 A, DC–5 kHz
70
15000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 45

Description
KGS 45 SiC AC/DC source and load, 45 kVA, AC 450 V L-N, DC 636 V, 70 A/phase, DC–5 kHz
Current [A]
70
Power [P]
45000
Voltage [V]
450
KGS 45
KGS 45 SiC AC/DC source and load, 45 kVA, AC 450 V L-N, DC 636 V, 70 A/phase, DC–5 kHz
70
45000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 90

Description
KGS 90 SiC AC/DC source and load, 90 kVA, AC 450 V L-N, DC 636 V, 140 A/phase, DC–5 kHz
Current [A]
140
Power [P]
90000
Voltage [V]
450
KGS 90
KGS 90 SiC AC/DC source and load, 90 kVA, AC 450 V L-N, DC 636 V, 140 A/phase, DC–5 kHz
140
90000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 135

Description
KGS 135 SiC AC/DC source and load, 135 kVA, AC 450 V L-N, DC 636 V, 210 A/phase, DC–5 kHz
Current [A]
210
Power [P]
135000
Voltage [V]
450
KGS 135
KGS 135 SiC AC/DC source and load, 135 kVA, AC 450 V L-N, DC 636 V, 210 A/phase, DC–5 kHz
210
135000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 180

Description
KGS 180 SiC AC/DC source and load, 180 kVA, AC 450 V L-N, DC 636 V, 280 A/phase, DC–5 kHz
Current [A]
280
Power [P]
180000
Voltage [V]
450
KGS 180
KGS 180 SiC AC/DC source and load, 180 kVA, AC 450 V L-N, DC 636 V, 280 A/phase, DC–5 kHz
280
180000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 270

Description
KGS 270 SiC AC/DC source and load, 270 kVA, AC 450 V L-N, DC 636 V, 420 A/phase, DC–5 kHz
Current [A]
420
Power [P]
270000
Voltage [V]
450
KGS 270
KGS 270 SiC AC/DC source and load, 270 kVA, AC 450 V L-N, DC 636 V, 420 A/phase, DC–5 kHz
420
270000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 360

Description
KGS 360 SiC AC/DC source and load, 360 kVA, AC 450 V L-N, DC 636 V, 560 A/phase, DC–5 kHz
Current [A]
560
Power [P]
360000
Voltage [V]
450
KGS 360
KGS 360 SiC AC/DC source and load, 360 kVA, AC 450 V L-N, DC 636 V, 560 A/phase, DC–5 kHz
560
360000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS 450

Description
KGS 450 SiC AC/DC source and load, 450 kVA, AC 450 V L-N, DC 636 V, 700 A/phase, DC–5 kHz
Current [A]
700
Power [P]
450000
Voltage [V]
450
KGS 450
KGS 450 SiC AC/DC source and load, 450 kVA, AC 450 V L-N, DC 636 V, 700 A/phase, DC–5 kHz
700
450000
450
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS Custom

Description
KGS Customized Customized SiC AC/DC source and load, optionally up to 900 V L-N, project-specific configuration
Current [A]
10000
Power [P]
10000000
Voltage [V]
50000
KGS Custom
KGS Customized Customized SiC AC/DC source and load, optionally up to 900 V L-N, project-specific configuration
10000
10000000
50000
4Q AC/DC Amplifier

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC source

Current-controlled CC

Source + Load

Single-/Three-phase

KGS bidirectional AC/DC source and load overview

The KGS series is a modular bidirectional AC/DC power system based on SiC MOSFET PWM technology. It operates as a programmable source or regenerative load and provides AC, DC and AC+DC outputs. The documented power range extends from 15 kVA to 1,080 kVA, while the listed standard models cover KGS 15 through KGS 540. AC applications support up to 450 V L-N and frequencies from DC to 5 kHz. In DC operation, each 15 kW module provides up to 636 V with bidirectional current up to ±70 A per channel. The three phases can be programmed independently or paralleled for a single-phase output. Grid simulation, regenerative load modes, sequences, harmonics and inter-harmonics, plus analog power-amplifier operation make KGS a versatile platform for development, validation and automated test systems.

Key benefits

Source and regenerative load

Bidirectional AC/DC operation enables transitions between delivering and absorbing energy within one system.

Wide frequency range

AC output from DC to 5 kHz and 10 kHz small-signal bandwidth support grid and aircraft-bus simulations.

Independent phases

Voltage, phase angle and other parameters are programmable per phase; paralleling creates a high-current single-phase output.

Repeatable sequences

Multi-step profiles control voltage, frequency, phase angle, ramp and dwell times for dynamic test routines.

Harmonics and inter-harmonics

Up to the 100th harmonic and eight inter-harmonic channels can be edited by amplitude and phase.

Open test-system integration

LAN, RS485, ATI, TTL and SCPI complement local TFT touch operation for automated test systems.

Operating principle and modes

The bidirectional power stage operates as an AC/DC source or regenerative electronic load depending on the test scenario. AC, DC and AC+DC are available in source operation, with CV or CC regulation. Load operation provides CC, CP and CR modes as well as complex RLC and non-linear RCD topologies. A crest factor from 1.414 to 3 can be superimposed on CC and CP load profiles.

FunctionSettingsTechnical purpose
AC sourceVoltage, frequency, phase angle, current and power limits, optional DC offsetDefined single- or three-phase supplies and grid events
DC source/sinkCV, positive/negative current and power limits, internal resistanceBidirectional DC testing on three channels
Regenerative AC loadCC, CP, CR, crest factor and leading/lagging phase angleLinear, capacitive, inductive and rectifier-type load conditions
RLC/RCD simulation12 RLC and 4 RCD topologies, parameterized separately per phaseRepeatable complex and non-linear load emulation
ATI power amplifierAnalog setpoint via BNC, ±5 VReproduction of external waveforms with no more than 20 µs delay

Power range and technical characteristics

ParameterValueCondition
System power15 kVA to 1,080 kVAModular series range
AC voltage and current450 V L-N, 70 APer 15 kW module, DC to 65 Hz
AC range 65–1,000 Hz375 V L-N, 70 APer 15 kW module
AC range 1,000–2,000 Hz350 V L-N, 70 APer 15 kW module
AC range 2,000–3,000 Hz250 V L-N, 60 APer 15 kW module
AC range 3,000–5,000 Hz150 V L-N, 50 APer 15 kW module
DC output0–636 V, ±70 A/channelPer 15 kW module
Voltage/current slew rate≥5 V/µs / ≥0.5 A/µsProgrammable ramps also available
Regulation0.1% FSLoad and line regulation
Resolution0.1 V; 0.01 A; 0.001 kWVoltage, current and power

AC accuracy depends on frequency. Between 45 and 70 Hz, voltage, current and power accuracy are each specified as 0.1% FS; the higher values stated in the technical data apply outside this range. AC voltage THD is below 0.3% FS at 15–50 Hz and below 0.4% FS at 50–500 Hz, measured at 250 V L-N with a resistive load.

Standard models

ModelPowerMax. AC outputMax. DC outputDimensions W × D × HWeight
KGS 1515 kVA450 V L-N, 70 A0–636 V, ±70 A800 × 900 × 1,100 mm300 kg
KGS 4545 kVA450 V L-N, 70 A/phase0–636 V, ±70 A800 × 900 × 1,500 mm460 kg
KGS 9090 kVA450 V L-N, 140 A/phase0–636 V, ±140 A900 × 900 × 2,200 mm900 kg
KGS 135135 kVA450 V L-N, 210 A/phase0–636 V, ±210 A1,600 × 900 × 1,800 mm1,050 kg
KGS 180180 kVA450 V L-N, 280 A/phase0–636 V, ±280 A1,600 × 900 × 2,200 mm1,200 kg
KGS 270270 kVA450 V L-N, 420 A/phase0–636 V, ±420 A2,400 × 900 × 2,200 mm1,800 kg
KGS 360360 kVA450 V L-N, 560 A/phase0–636 V, ±560 A3,200 × 900 × 2,200 mm2,400 kg
KGS 450450 kVA450 V L-N, 700 A/phase0–636 V, ±700 A4,000 × 900 × 2,200 mm2,900 kg
KGS 540540 kVA450 V L-N, 840 A/phase0–636 V, ±840 A4,800 × 900 × 2,200 mm3,600 kg

For single-phase operation, the three phase outputs are connected in parallel, tripling the available output current relative to the stated three-phase current per phase. Parallel operation of multiple systems requires identical units with the same power, voltage and current ratings.

Typical applications

Energy-storage PCS

Bidirectional energy flow and programmable grid events support testing of grid-connected power conversion systems.

Avionics power networks

Variable frequency, voltage dips, interruptions and sequences reproduce normal and disturbed aircraft-bus supply conditions.

UPS and converter testing

RLC and RCD topologies generate complex and non-linear loads for testing UPS systems and power converters.

Automated test systems

SCPI, LAN, RS485, analog control and saved sequences simplify integration into ATE and production test stands.

Short-circuit testing

Programmable current limiting and a short-circuit-capable output support defined protection tests, including PV inverter scenarios.

Interfaces, software and installation

EquipmentFunctionNote
TFT touch GUISettings, measurements, harmonic analysis, waveform capture and fault display12-inch panel with Windows operating system
LAN / RS485Remote control and automated routinesRS485 at 9,600 baud, 8N1
ATIAnalog setpoint input for power-amplifier operationBNC, ±5 V
TTLTrigger signal when voltage or frequency changesFor oscilloscope capture
Remote senseCompensation for voltage drop to the device under testConnected to the output at the factory
Master-slaveParallel connection of identical systemsOptical communication link
CharacteristicConfiguration
Standard AC input3P+N+PE, 380 V L-L ±10%, 47–63 Hz
Other input configurations/400 and /480 for 400 or 480 V L-L ±10%; 3P+N+PE or 3P+PE
Options-BP for bipolar DC output; -HV900 for up to 900 V L-N subject to consultation
Cooling and environmentForced-air cooling; operation at 0–40 °C; 20–90% RH, non-condensing
ProtectionOVP, OCP, OPP and OTP; IP21; local and external emergency-stop interface

KGS series FAQ

Which output types does KGS support?

The series provides AC, DC and AC+DC and operates as a source or regenerative load depending on the selected mode.

Is 450 V L-N available up to 5 kHz?

No. 450 V L-N applies up to 65 Hz; the maximum voltage and current decrease in steps as frequency rises.

Which load modes are available?

CC, CP and CR are available, together with twelve RLC and four RCD topologies for complex and non-linear loads.

Is single-phase output possible?

Yes. Paralleling the three phase outputs provides three times the stated three-phase current per phase.

Can multiple systems operate in parallel?

Yes. Master-slave parallel operation is intended for identical units with the same power, voltage and current ratings.

How is KGS automated?

Remote control uses LAN or RS485 and SCPI; ATI analog input and TTL triggering are also available.

Is bipolar DC output available?

Yes. The -BP option adds bipolar DC output, with the appropriate configuration selected for the project.

Can KGS test PV inverters?

Yes. Programmable grid events, low- and zero-voltage ride-through, harmonics and short-circuit conditions support corresponding inverter tests.

Is KGS suitable for energy-storage PCS?

Yes. Bidirectional operation and freely defined grid conditions enable testing of the electrical characteristics of grid-connected PCS.

Can avionics power networks be simulated?

Yes. Variable frequencies, interruptions, abnormal supply conditions, start-up and power-failure scenarios can be reproduced.

Technical consultation and project enquiry

Configuring a KGS system requires the power rating, AC/DC/AC+DC operation, voltage, current and frequency ranges, source and load profiles, phase configuration, AC input, interfaces and options. ET System supports model selection, test-profile definition and system integration.

Discuss your KGS project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly