Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Info Download
ETS Control

Info Download
Request free software here (information & download).
ETS Control
Request free software here (information & download).
Software

LAB/ETS Control overview

LAB/ETS Control is operating, monitoring and simulation software for programmable DC power supplies from the LAB/SMP, LAB/SMS and LAB/HP series. Connected devices can be selected, configured and managed through dedicated control and measurement panels. The interface transfers voltage and current setpoints, switches the output, and continuously displays voltage, current, power and resistance.

UI/VC, UIP/VCP, UIR/VCR, PVSim, USER and SCRIPT modes support different test tasks. The software also provides user-defined sequences, data logging, user limits, protection parameters, and parallel, series and independent master-slave configurations. Its PV functions generate static and dynamic I-V and P-V curves, process irradiance and temperature profiles, and visualize MPP tracking and MPPT efficiency. A demo device lets users explore the operating workflows without a connected power supply.

Key benefits

Multiple devices in one interface

Each connected power supply has dedicated control and measurement panels; setpoints, outputs and measurements can also be managed across devices.

PV curves and MPPT

Static and dynamic simulations display I-V and P-V characteristics and capture MPP values and MPPT efficiency.

Traceable measurement series

Measurement, sequence and PV data can be stored locally with a selectable logging interval.

Repeatable test workflows

Sequences combine voltage and current values with delays, while scripts process up to 1,000 commands.

Defined operating limits

User limits and adjustable voltage and current slopes constrain setpoints and shape transitions between operating points.

Practice without hardware

The demo device emulates a connection and makes the software functions available for training, development and demonstrations.

Operating modes and functional principle

LAB/ETS Control transfers setpoints and operating commands to the connected power supply and visualizes the returned values. The available setting range follows the hardware and user limits of the selected device.

ModeOperationTypical purpose
UI / VCVoltage and current setpoints are transferred directly to the controller.Direct definition of a DC operating point
UIP / VCPAdds an adjustable power limit to the voltage and current settings.Operation within a defined power limit
UIR / VCRRegulates the voltage setpoint to emulate an adjustable internal resistance; the current setpoint acts as the limit.Emulation of a source with internal resistance
PVSimGenerates a PV curve from Voc, Isc, Vmp and Imp and runs static or dynamic simulations.Investigation of MPPT and PV inputs
USERTransfers user-defined voltage and current points to the device.Custom characteristics and freely defined profiles
SCRIPTExecutes loaded or manually assembled command sequences.Automated, repeatable control workflows

Separate digital PID controllers are provided for UIR, UIP and PVSim. Proportional, integral and derivative components can be configured for each controller.

Supported device series and connections

The software is designed for programmable DC power supplies from the LAB/SMP, LAB/SMS and LAB/HP families. The actual setpoint and protection ranges are read from the connected device and displayed as hardware limits in the interface.

ConnectionSoftware setupDetails
LAN / TCPAutomatic device discovery or manual additionIP address and port
RS232Serial discovery or manual additionCOM port and baud rate
USBDirect connection between the power supply and computerSupported device connection
IEEE-488 / GPIBManual additionPrimary address and GPIB board number

Previously used devices remain available in the Recent Devices list together with device data and connection settings. New devices can be discovered, rescanned or added manually using their connection parameters.

Static and dynamic PV simulation

In static PV operation, LAB/ETS Control calculates the I-V and P-V curves from open-circuit voltage Voc, short-circuit current Isc, and voltage Vmp and current Imp at the maximum power point. During the simulation, the MPP is tracked, MPPT efficiency is displayed, and Vmp, Imp, MPP power and efficiency can be logged at a freely selectable interval.

Dynamic PV simulation combines module curves with time-dependent irradiance and temperature profiles. Preset profiles can be loaded and supplemented with custom files. Module curves are available from Sandia National Laboratories and California Energy Commission libraries, and the associated curve parameters can be adjusted. The irradiance rate of change is adjustable from 1 to 200 W/m²/s.

Shading simulation: The PV generator can combine at least two shading profiles. Using a single-diode model, the software calculates adjusted Vmp and Imp values and displays the resulting I-V and P-V curves together with MPPT efficiency.

Scripts, sequences and data logging

FunctionCapabilitiesResult
Script modeLoad commands from a text file, enter them manually or program them through the digital interface; up to 1,000 commandsWorkflows with setpoints, modes, delays, loops, standby and output control
Script ViewLoad an example, load a file, clear the list and start the scriptExecute a command list directly in the application
Sequence ViewCreate rows with voltage, current and delay, load them from a file, edit, save, repeat or abort themTabular workflow with display of the active step
Sequence loggingStore voltage and current with an adjustable interval in millisecondsLocal measurement file for the executed workflow
PV loggingStore Vmp, Imp, MPP power, MPPT efficiency, irradiance and temperature at intervals in secondsLocal data for evaluating the PV simulation

When loading a sequence, the software checks its voltage and current values against the configured user limits. Values outside these limits are not transferred to the device.

Multi-device and master-slave operation

Multiple connected power supplies are maintained in a device list and each has dedicated control and measurement panels. This allows setpoints, outputs and measurements to be managed for several devices without rebuilding the connection when switching between them.

Parallel

Supports coordinated operation of parallel-connected units to increase available current at a common voltage.

Series

Supports coordinated operation of series-connected units to increase available voltage at a common current.

Independent

Allows each unit to use its own voltage and current settings for different tasks within the same setup.

The selected electrical topology and the permitted device combination depend on the connected power supplies and the specific test setup.

Limits and protection parameters

User-defined voltage and current limits remain within the hardware limits read from the device. Voltage and current slopes can also be configured to define the rate of change during setpoint transitions.

ParameterSettingEffect
User limitsMinimum and maximum voltage plus current limitsRestricts the setpoints permitted by the software
Voltage and current slopeRate of change for setpoint transitionsDefines how quickly voltage or current reaches the new value
OVP, UVP and OCPOvervoltage, undervoltage and overcurrentConfigures the device response to limit violations
UVP and OCP delayUVP: 100 to 1,000 ms; OCP: 1 to 5,000 msAllows brief voltage or current transients before activation
FoldbackCC, CV, CP or OFF; delay 10 to 10,000 msDefines the operating mode and response delay of the foldback function

Typical applications

MPPT testing of PV inverters

Static I-V and P-V curves supply the PV input with defined operating points and display MPP tracking and MPPT efficiency.

Dynamic irradiance and shading

Time profiles for irradiance and temperature plus combined shading profiles investigate MPPT behavior under changing conditions.

Recurring laboratory workflows

Scripts and sequences transfer defined setpoints, delays and loops, while data logging records the measurements for the workflow.

Multi-device test benches

Multiple power supplies can be managed through separate control panels or coordinated in supported parallel, series and independent configurations.

Training and software testing

The demo device emulates a connection so operating workflows can be explored and demonstrated without a connected power supply.

FAQ about LAB/ETS Control

Which power supplies are supported?

The software is intended for programmable DC power supplies from the LAB/SMP, LAB/SMS and LAB/HP series. Available functions and limits follow the connected device.

How are devices connected?

RS232, LAN/TCP, USB and IEEE-488/GPIB are provided. TCP and serial devices can be discovered or added manually with their connection parameters.

Can multiple power supplies be operated at the same time?

Yes. Connected devices have dedicated control and measurement panels. Parallel, series and independent master-slave modes are also available for suitable system configurations.

Which values can be logged?

Sequence operation stores voltage and current. PV simulation additionally logs Vmp, Imp, MPP power, MPPT efficiency, irradiance and temperature.

Can LAB/ETS Control test the MPPT of a PV inverter?

Yes. PVSim generates static or dynamic I-V and P-V curves, tracks the maximum power point and displays MPPT efficiency.

Can changing irradiance and shading be emulated?

Yes. Custom or preset irradiance and temperature profiles can be combined with module curves. The PV generator adds configurable shading profiles.

How are repeatable test workflows created?

Sequences combine voltage, current and delay in a table. Script mode adds command lists with loops, waiting periods, modes and output control.

Can operation be prepared without a connected power supply?

Yes. The demo device emulates a device connection and provides the software controls for training, development and demonstration.

Technical consultation and project enquiry

To select a suitable LAB/ETS Control configuration, we need the device series in use, the intended interface, the number and topology of the power supplies, and the required operating modes, PV profiles, sequences and logging data.

Discuss your LAB/ETS Control project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly