ESA 45-300-68

Description
ESA 45-300-68 Bidirectional programmable AC source, 45 kVA, 300 V L-N, 68 A/phase
Current [A]
91
Power [P]
45000
Voltage [V]
300
ESA 45-300-68
ESA 45-300-68 Bidirectional programmable AC source, 45 kVA, 300 V L-N, 68 A/phase
91
45000
300
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA 60-300-91

Description
ESA 60-300-91 Bidirectional programmable AC source, 60 kVA, 300 V L-N, 91 A/phase
Current [A]
182
Power [P]
60000
Voltage [V]
300
ESA 60-300-91
ESA 60-300-91 Bidirectional programmable AC source, 60 kVA, 300 V L-N, 91 A/phase
182
60000
300
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA 180-300-273

Description
ESA 180-300-273 Bidirectional programmable AC source, 180 kVA, 300 V L-N, 273 A/phase
Current [A]
273
Power [P]
180000
Voltage [V]
300
ESA 180-300-273
ESA 180-300-273 Bidirectional programmable AC source, 180 kVA, 300 V L-N, 273 A/phase
273
180000
300
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA 240-300-364

Description
ESA 240-300-364 Bidirectional programmable AC source, 240 kVA, 300 V L-N, 364 A/phase
Current [A]
364
Power [P]
240000
Voltage [V]
300
ESA 240-300-364
ESA 240-300-364 Bidirectional programmable AC source, 240 kVA, 300 V L-N, 364 A/phase
364
240000
300
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA 300-300-455

Description
ESA 300-300-455 Bidirectional programmable AC source, 300 kVA, 300 V L-N, 455 A/phase
Current [A]
455
Power [P]
300000
Voltage [V]
300
ESA 300-300-455
ESA 300-300-455 Bidirectional programmable AC source, 300 kVA, 300 V L-N, 455 A/phase
455
300000
300
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA Custom

Description
ESA Customized Customized bidirectional AC source, project-specific configuration
Current [A]
10000
Power [P]
10000000
Voltage [V]
50000
ESA Custom
ESA Customized Customized bidirectional AC source, project-specific configuration
10000
10000000
50000
AC Source/ Load (1/3ph)

Technical Data

Product category

AC Bidirectional

AC Electronic Load

AC Power Supply

Type of AC Load

Regenerative Load

Type of AC source

Source + Load

Grid simulator

Single-/Three-phase

ESA Series overview

The ESA Series is a modular three-phase AC power source for grid simulation, power-electronics development and automated testing. Standard models cover 45 to 300 kVA at 0 to 300 V L-N; voltage, current, power and input connection are configured for the project. Three DC/AC power channels generate independent phase outputs. Standard operation provides AC output, CV and CC control, sequences, harmonics, interharmonics, user-defined waveforms, measurement functions and both local and PC-based operation.

The -R option adds four-quadrant operation with bidirectional energy flow, turning the ESA into a regenerative grid simulator. -LD expands this configuration with regenerative AC load modes, while -DC adds DC and AC+DC output. Further options cover line-impedance simulation, single-phase operation, islanding scenarios and customer-specific frequency ranges. The hardware can therefore be configured for the specific test task without treating optional functions as standard equipment.

Key benefits

Bidirectional grid operation

With -R, the ESA operates in four quadrants and returns absorbed energy. This supports tests with changing active-power direction.

Fast voltage transitions

Voltage rise and fall times are below 1 ms in the standard configuration, enabling dynamic dips and recovery profiles.

Programmable power quality

Harmonics up to the 50th order and interharmonics are programmed per phase by amplitude and angle.

Voltage at the DUT

Remote sense feeds the load voltage back into the control loop, compensating for voltage drops in the connection leads.

Repeatable test profiles

Multi-step routines combine setpoints, ramps and dwell times. Settings can be saved and imported for recurring tests.

Measurement and waveform recording

DSP/FPGA control supports real-time measurements plus waveform display and storage at a 10 k/s sampling rate.

How the three-phase AC power source works

In the standard topology, the three-phase mains input is followed by a transformer, filters and a PWM AC/DC stage. The resulting DC link supplies three DC/AC power modules that generate phases A, B and C independently. Voltage or current is regulated in CV or CC mode; frequency and phase angle are programmable. The topology of a unit with -R is designed for bidirectional energy flow and differs from the standard configuration.

STD mode is used for individual operating points. SEQ and List modes link multiple steps with ramps, dwell times, phase angles and optional waveform components. The graphical user interface runs on the front Windows touch panel and can also be used on a connected PC. Measurements, status, faults and input/output waveforms are displayed centrally.

Power range and standard models

The following standard models provide an AC output up to 300 V L-N. Current is specified per phase; dimensions and weight refer to the respective cabinet configuration.

ModelPowerVoltage L-NCurrent per phaseW × D × HWeight
ESA 45-300-6845 kVA300 V68 A800 × 800 × 2,000 mm770 kg
ESA 60-300-9160 kVA300 V91 A800 × 800 × 2,100 mm980 kg
ESA 120-300-182120 kVA300 V182 A1,600 × 900 × 1,700 mm1,400 kg
ESA 180-300-273180 kVA300 V273 A1,600 × 900 × 2,100 mm1,800 kg
ESA 240-300-364240 kVA300 V364 A1,800 × 900 × 2,100 mm2,100 kg
ESA 300-300-455300 kVA300 V455 A2,000 × 1,000 × 2,100 mm2,700 kg

Check the configuration: The model code follows ESA AAA-BBB-CCC-DDD/EEE for power, voltage, current per phase, options and input connection. Customer-specific units may differ; the quotation, nameplate and project-specific design define the delivered configuration.

Dynamics, accuracy and regulation

CharacteristicValue / conditionRelevance
Voltage rise, 0–90%<1 ms standard; <2 ms with -TRDynamic setpoint changes and ride-through profiles
Voltage fall, 90–0%<1 ms standard; <2 ms with -TRDefined dips and shut-down transitions
Load regulation0.2% FSLimited output deviation during load changes
Line regulation0.1% FSLimited output deviation during input variation
Output-voltage THD<1% FS with resistive load at 50/60 HzDefined sinusoidal reference conditions
Programming accuracyPower 0.3% FS; voltage 0.1% FS standard / 0.2% FS with -TR; current 0.2% FSClassification of programmed setpoints
Frequency / phase0.01 Hz; ±0.3° at 50 HzPrecise frequency and phase control
Resolution0.1 kW; 0.01 V; 0.1 A; 0.01 Hz; 0.1°Fine increments for programmed test parameters

Operating modes and options

FunctionConfigurationOperation and use
CV / CCStandardRegulates AC output voltage or current for individual operating points and programmed routines.
STD, SEQ and ListStandardSingle-step, multi-step sequence or freely combined command lists with ramps, dwell times and loops.
Four-quadrant operation-RSources and absorbs AC power for regenerative grid simulation and bidirectional testing.
Regenerative AC load-LD together with -RCR, CC, CP and rectifier modes for resistive, inductive, capacitive and nonlinear load profiles.
DC and AC+DC-DCAdds DC output and a DC component to the three phase channels. Up to 50% output power is available in DC mode; current is derated below 30 Hz.
Line impedance-IMPSimulates R and L at the output; Rmax = 0.2 × Urated / Irated, Lmax = Rmax / 314.
Single-phase output-1PParallel connection of the three phase outputs raises available single-phase current to the sum of the channels.
Islanding detection-62116RLC load simulation for anti-islanding tests with a sine waveform and 50/60 Hz input.
Active/reactive power control-PQDecoupled P and Q setpoints for energy-flow and power-system research.
Extended frequency-HFXXXCustomer-specific extension of the AC frequency range in CV mode.

Typical applications

Grid-connected generation systems

With -R, the ESA generates voltage and frequency deviations, phase jumps, unbalance and LVRT/HVRT profiles for compliance testing.

Solid-state transformers and microgrids

With -PQ, active and reactive power are set independently to investigate power transfer and load balancing between grid sections.

Motor drives and power electronics

Independent phases, programmable frequency and user-defined waveforms supply converters and assemblies under repeatable conditions.

Automated production testing

Remote setpoints, sequences, SCPI/Modbus plus status and fault feedback integrate the power source into automated test stands.

Power-quality research

Harmonics, interharmonics, unbalance and user-defined waveforms enable controlled investigations of three-phase DUTs.

Interfaces, software and automation

EquipmentAvailabilityFunction
LANStandardRemote control from a PC in the same network segment; local touch-panel communication uses separate internal LAN ports.
RS485StandardRemote control and noise-resistant multidrop communication over a two-wire link with signal ground.
SCPI / ModbusSupported protocolsProgrammed setpoints, operating modes, measurement queries and status control.
RS232-232Point-to-point remote control through the optional serial interface.
Analogue input-ATIExternal output-voltage setpoint control through BNC connectors.
TTL outputStandardProvides an observable trigger signal when voltage or frequency changes.
Remote senseStandardRegulates voltage at the DUT connection point rather than only at the instrument terminals.
Windows GUIStandardOperation on the at least 12-inch touch panel or a PC, measurement display, waveform capture, storage and fault display.

Parallel operation and scaling

Units of the same model can operate in parallel with the -MS option. One unit is configured as Parallel Master and the other as Parallel Slave; communication uses optical fibre. Input and output connections are wired in parallel accordingly. Setpoints are entered at the master, while each unit's measurement page displays its local values.

System design: Parallel operation requires identical units, the intended master-slave connection and project-specific AC/output cabling. Confirm the permitted unit count and total power for the specific configuration.

Installation and infrastructure

CharacteristicRequirement / configuration
AC inputDepending on the order: 380, 400 or 480 V L-L ±10%, as 3P+N+PE or 3P+PE; check the actual configuration on the nameplate.
Input frequency47–63 Hz
OutputThree-phase N/A/B/C; standard range 0–300 V L-N
CoolingForced-air cooling; water cooling with -W. Allow at least 600 mm clearance from walls or other equipment for ventilation.
Operating temperature0–40 °C
Humidity20–90% relative humidity, non-condensing
ConnectionsCable entry from below; input and output busbars plus PE connection are designed for the project's voltage, current and cooling configuration.

Before installation, check the model, voltage and current ratings on the nameplate. Protective earth, AC supply cable, output wiring, upstream switching equipment and floor space must be sized for the specific cabinet configuration.

Protection and safety functions

The ESA monitors overcurrent, overvoltage, overpower and overtemperature. The user interface also provides settings for undervoltage, peak-current limitation, and voltage and current ramps. If a configured OCP, OVP or OPP threshold is exceeded, the output is switched off; status and faults are shown in the GUI.

An emergency-stop button is located on the front panel. An external emergency-stop interface is also provided for connection of a customer-side switch. These instrument functions do not replace the risk assessment and protective architecture of the complete test stand.

ESA FAQ

Is every ESA configuration bidirectional?

No. Four-quadrant operation with regenerative energy flow is provided by the -R option. Standard and optional equipment must match the individual configuration.

Which standard models are documented?

The standard overview contains six models from 45 to 300 kVA, each up to 300 V L-N and with 68 to 455 A per phase.

Can the three phases be set independently?

Yes. Voltage, phase angle, sequence, harmonic and interharmonic parameters can be defined individually for each phase.

Can the ESA operate as a regenerative AC load?

Yes, with -LD together with -R. CR, CC, CP and rectifier modes are available; the phase angle in CC/CP ranges from +90° to -90°.

Is DC output available?

The -DC option provides DC and AC+DC operation. Up to 50% output power is available in DC mode; current is derated below 30 Hz.

How is voltage drop in the load leads compensated?

Remote sense measures voltage at the DUT input and feeds it back to the control loop. The factory terminal link is rewired accordingly.

Can the ESA perform grid-fault and ride-through tests?

With -R, the ESA generates voltage and frequency deviations, dips, unbalance and LVRT/HVRT profiles for grid-connected DUTs.

Can the ESA support anti-islanding tests on PV inverters?

With -62116, the ESA simulates an RLC load for anti-islanding tests. This function is limited to a sine waveform and 50/60 Hz input.

How is the ESA integrated into automated test stands?

LAN, RS485, SCPI and Modbus control setpoints and read measurements or status data. Sequence and List modes implement repeatable development and production routines.

Technical consultation and project enquiry

To select an ESA configuration, provide power, voltage and current per phase, input supply, frequency range and required operating modes. Also specify dynamics, waveform, load or grid-simulation functions, interfaces, cooling and the planned parallel configuration.