Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
EAC-S 250

Description
EAC-S 250 Linear 1-phase AC power source, 250 VA, 0–300 VAC / 0–425 VDC, 0–3 A, 4U
Current [A]
3
Power [P]
250
Voltage [V]
300
EAC-S 250
EAC-S 250 Linear 1-phase AC power source, 250 VA, 0–300 VAC / 0–425 VDC, 0–3 A, 4U
3
250
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 500

Description
EAC-S 500 Linear 1-phase AC power source, 500 VA, 0–300 VAC / 0–425 VDC, 0–6 A, 4U
Current [A]
6
Power [P]
500
Voltage [V]
300
EAC-S 500
EAC-S 500 Linear 1-phase AC power source, 500 VA, 0–300 VAC / 0–425 VDC, 0–6 A, 4U
6
500
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 1000

Description
EAC-S 1000 Linear 1-phase AC power source, 1,000 VA, 0–300 VAC / 0–425 VDC, 0–10 A, 6U
Current [A]
10
Power [P]
1000
Voltage [V]
300
EAC-S 1000
EAC-S 1000 Linear 1-phase AC power source, 1,000 VA, 0–300 VAC / 0–425 VDC, 0–10 A, 6U
10
1000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 2000

Description
EAC-S 2000 Linear 1-phase AC power source, 2,000 VA, 0–300 VAC / 0–425 VDC, 0–15 A, 6U
Current [A]
15
Power [P]
2000
Voltage [V]
300
EAC-S 2000
EAC-S 2000 Linear 1-phase AC power source, 2,000 VA, 0–300 VAC / 0–425 VDC, 0–15 A, 6U
15
2000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 3000

Description
EAC-S 3000 Linear 1-phase AC power source, 3,000 VA, 0–300 VAC / 0–425 VDC, 0–20 A, 10U
Current [A]
20
Power [P]
3000
Voltage [V]
300
EAC-S 3000
EAC-S 3000 Linear 1-phase AC power source, 3,000 VA, 0–300 VAC / 0–425 VDC, 0–20 A, 10U
20
3000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 4000

Description
EAC-S 4000 Linear 1-phase AC power source, 4,000 VA, 0–300 VAC / 0–425 VDC, 0–30 A, 16U
Current [A]
30
Power [P]
4000
Voltage [V]
300
EAC-S 4000
EAC-S 4000 Linear 1-phase AC power source, 4,000 VA, 0–300 VAC / 0–425 VDC, 0–30 A, 16U
30
4000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 5000

Description
EAC-S 5000 Linear 1-phase AC power source, 5,000 VA, 0–300 VAC / 0–425 VDC, 0–35 A, 16U
Current [A]
35
Power [P]
5000
Voltage [V]
300
EAC-S 5000
EAC-S 5000 Linear 1-phase AC power source, 5,000 VA, 0–300 VAC / 0–425 VDC, 0–35 A, 16U
35
5000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 6000

Description
EAC-S 6000 Linear 1-phase AC power source, 6,000 VA, 0–300 VAC / 0–425 VDC, 0–40 A, 16U
Current [A]
40
Power [P]
6000
Voltage [V]
300
EAC-S 6000
EAC-S 6000 Linear 1-phase AC power source, 6,000 VA, 0–300 VAC / 0–425 VDC, 0–40 A, 16U
40
6000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 7000

Description
EAC-S 7000 Linear 1-phase AC power source, 7,000 VA, 0–300 VAC / 0–425 VDC, 0–50 A, 20U
Current [A]
50
Power [P]
7000
Voltage [V]
300
EAC-S 7000
EAC-S 7000 Linear 1-phase AC power source, 7,000 VA, 0–300 VAC / 0–425 VDC, 0–50 A, 20U
50
7000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 8000

Description
EAC-S 8000 Linear 1-phase AC power source, 8,000 VA, 0–300 VAC / 0–425 VDC, 0–60 A, 20U
Current [A]
60
Power [P]
8000
Voltage [V]
300
EAC-S 8000
EAC-S 8000 Linear 1-phase AC power source, 8,000 VA, 0–300 VAC / 0–425 VDC, 0–60 A, 20U
60
8000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 9000

Description
EAC-S 9000 Linear 1-phase AC power source, 9,000 VA, 0–300 VAC / 0–425 VDC, 0–70 A, 25U
Current [A]
70
Power [P]
9000
Voltage [V]
300
EAC-S 9000
EAC-S 9000 Linear 1-phase AC power source, 9,000 VA, 0–300 VAC / 0–425 VDC, 0–70 A, 25U
70
9000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S 10000

Description
EAC-S 10000 Linear 1-phase AC power source, 10,000 VA, 0–300 VAC / 0–425 VDC, 0–80 A, 25U
Current [A]
80
Power [P]
10000
Voltage [V]
300
EAC-S 10000
EAC-S 10000 Linear 1-phase AC power source, 10,000 VA, 0–300 VAC / 0–425 VDC, 0–80 A, 25U
80
10000
300
Linear 1-ph AC Source

Technical Data

Height

6

4

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-phase

EAC-S overview

The EAC-S is a programmable single-phase AC source for laboratories, industry and service engineering. Twelve models provide 250 to 10,000 VA, with rated currents from 3 to 80 A. The standard output covers 0–300 V AC and 0–425 V DC. Options extend the range to 500 or 700 V AC and 700 or 1,000 V DC, with a reduced current limit in each case. In addition to pure AC and DC signals, the source can superimpose an adjustable DC component on an AC waveform. Sine, square and triangle can be selected directly; three non-volatile memory locations store user-defined waveforms. The standard frequency range extends to 500 Hz, with optional extensions to 1,000 or 2,000 Hz. Operation and measurement display are available at the front panel. Automated test systems can use optional analog and digital interfaces, synchronization, external signals, and SD-card-based waveform, script and data-logging functions.

Key benefits

Reproduce diverse supply conditions

AC, DC and mixed AC+DC signals enable investigation of alternating voltage, DC components and superimposed waveforms with one source.

Broadly graduated power range

Twelve models from 250 to 10,000 VA help match power, current, rack height and mains connection to the test system.

Standard and custom waveforms

Sine, square, triangle and three stored 16-bit waveforms with 3,600 points support reproducible signal profiles.

Integrated electrical measurements

The display covers RMS, DC and peak values as well as active, reactive and apparent power, power factor and crest factor.

Sequences without a control PC

The optional SD card executes scripts with up to 100 commands and logs measurement values at adjustable intervals.

Ready for test-system integration

Optional analog, serial, USB, LAN and IEEE-488 interfaces plus sync I/O connect setpoints, status and measurements to automation.

Linear technology compared with switch-mode sources

The EAC-S uses a linear output stage in which an analog power amplifier continuously reproduces the specified waveform at the output. In contrast, switch-mode sources generate their output voltage by rapidly switching the power semiconductors. Linear technology supports a particularly clean waveform with low levels of switching-related high-frequency components, making it especially suitable for sensitive measurement, development and testing applications. Switch-mode sources generally offer higher efficiency, lower heat dissipation and more compact dimensions. The preferred technology therefore depends on whether signal quality or energy efficiency and power density are the primary consideration.

Operating principle of the single-phase AC source

After galvanic isolation, the supply voltage is rectified and feeds an analog power amplifier. Its target waveform comes from a table containing one complete period. The table can represent a fixed waveform, a stored user-defined curve or, with the corresponding option, an external oscillator signal. Amplitude and limiting settings determine the output signal.

In voltage mode, the output voltage follows the selected waveform; if the set RMS current is exceeded, the source reduces the amplitude. The DC component is set with its own polarity and added to the AC component. Depending on the installed equipment, setpoints can be supplied from the front panel, analog I/O, a digital interface or the memory card.

Models and standard output range

All listed standard models provide 0–300 V AC and 0–425 V DC. Power, maximum current limit and enclosure size differ as follows:

ModelPowerMaximum currentDimensions
EAC-S 250250 VA3 A19-inch × 4U × 434.5 mm
EAC-S 500500 VA6 A19-inch × 4U × 434.5 mm
EAC-S 10001,000 VA10 A19-inch × 6U × 434.5 mm
EAC-S 20002,000 VA15 A19-inch × 6U × 434.5 mm
EAC-S 30003,000 VA20 A19-inch × 10U × 434.5 mm
EAC-S 40004,000 VA30 A19-inch × 16U × 600 mm
EAC-S 50005,000 VA35 A19-inch × 16U × 600 mm
EAC-S 60006,000 VA40 A19-inch × 16U × 600 mm
EAC-S 70007,000 VA50 A19-inch × 20U × 800 mm
EAC-S 80008,000 VA60 A19-inch × 20U × 800 mm
EAC-S 90009,000 VA70 A19-inch × 25U × 800 mm
EAC-S 1000010,000 VA80 A19-inch × 25U × 800 mm

Select the correct configuration: The maximum voltage and current values describe the limits of each instrument. The rated apparent power additionally limits the permissible operating point. With the /V500 and /V700 options, maximum current is reduced by 40 and 50%, respectively.

Voltage, frequency and regulation

CharacteristicValueCondition or configuration
Standard voltage range0–300 V AC / 0–425 V DCAll listed standard models
Option /V5000–500 V AC / 0–700 V DCMaximum current −40%
Option /V7000–700 V AC / 0–1,000 V DCMaximum current −50%
Frequencyup to 500 Hz; optionally up to 1,000 or 2,000 HzVariable setting in 0.1-Hz steps
Static voltage regulation0.1%Line and load regulation
Static current regulation0.1%Constant-current operation
Dynamic regulation5 periodsInstrument specification
Ripple0.3%at 50 Hz
Voltage programming accuracy100 mVAC and DC voltage
Current programming accuracy1 mA below 10 A; 10 mA from 10 ARMS constant current
Programming accuracy0.1 Hz / 0.1°frequency / activation phase

Operating modes and programmable functions

FunctionOperationBenefit in the test sequence
AC / DC / AC+DCAC signal, DC signal or AC waveform with an added DC componentGenerate different supply conditions with one instrument
Sine / square / triangleDirectly selectable standard waveformsReproducible basic signals without external waveform creation
User waveforms16-bit WAV files with 3,600 points; three internal memory locationsReuse individual periodic voltage profiles
External oscillatorOptional input signal is amplified; amplitude, limiting and delay are adjustableOutput external waveforms at the EAC-S power level
DIPDisables the output for a defined number of half-periods; digital interface requiredGenerate defined short voltage interruptions
GATE / APulsTimed output activation or adjustable pulse sequence; digital interface requiredAutomate time-dependent on/off profiles
Script modeOptionally executes up to 100 commands from the SD cardRun repeatable sequences without a permanent control PC
Data loggerSaves measurement values to the SD card at an adjustable intervalRecord test profiles for subsequent evaluation

Typical applications

Single-phase mains simulation

The EAC-S provides defined voltage, frequency and waveform to investigate device behavior under different single-phase supply conditions.

Voltage interruptions and switching profiles

With digital control, DIP, GATE and pulse functions generate defined off and on periods for reproducible disturbance scenarios.

Testing with custom waveforms

Stored WAV curves or an optional external oscillator signal reproduce periodic signals beyond the three standard waveforms.

Automated laboratory and industrial test systems

Remote setpoints, measurement queries and status signals integrate the source into computer-controlled sequences and ATE systems.

Standalone long-duration and repetitive tests

Optional scripts control the sequence while the data logger records operating status and electrical measurements on the memory card.

Interfaces and automation

Interface or optionConfigurationFunction
Front panelGraphical display and rotary pulse encodersOperate setpoints, waveform, frequency, phase, limiting and measurement displays
ATI 5 / ATI 10Galvanically isolated analog interface, optionalSet values with 0–5 or 0–10 V and monitor measurements
RS232 / RS485Optional, ASCII protocolRemote-control the instrument and query setpoints, measurements or status
USBOptional, virtual COM portRemote control using the serial-interface principle
LANOptional, TCP/IP or TelnetNetwork-based control through port 10001
IEEE-488OptionalIntegration into GPIB-based measurement and test systems
Sync input / sync outputIndividually optionalAlign the output waveform with an external source or trigger external measuring instruments
SD cardOptionalLoad waveforms, execute scripts and log measurement data

Installation and infrastructure

CharacteristicRequirement or configuration
Mains frequency47–63 Hz
Mains connectionDepending on the model, 1 × 230 V, 2 × 400 V or 3 × 400 V AC; optional 3 × 208 V and 3 × 480 V AC input variants
CoolingFan cooling; keep airflow paths clear according to the instrument dimensions
Operating temperature0–50 °C
Storage temperature−20 to +70 °C
Relative humidity< 80%
Operating altitude< 2,000 m
Weight30–437 kg depending on the model

Mains cabling, protective earth, circuit protection, connection type and installation space must be sized for the selected model. Before commissioning, the input voltage stated on the nameplate must match the available mains supply.

Protection and safety functions

The EAC-S monitors overtemperature and overpower conditions. If the permissible power is exceeded, the instrument reduces or disables the output depending on the magnitude and duration of the overload. Short-term peak power is specified for the EAC-S 250 through EAC-S 3000 models and may be applied for no more than ten seconds.

An interlock input is available as an option. It switches the power transformer on the primary side through a contactor, but does not provide output isolation according to VDE. These instrument functions therefore do not replace the higher-level safety concept of the test system.

EAC-S FAQ

How is the correct EAC-S model selected?

Determine the highest simultaneous operating point for voltage, current and apparent power, plus frequency, waveform, installation dimensions and available mains connection. Account for the reduced current limit of the 500 and 700 V options.

Can the EAC-S output pure DC voltage?

Yes. The output supports AC, DC and AC+DC operation. In mixed-signal operation, the selected DC component is added to the AC waveform.

Which waveforms are available?

Sine, square and triangle are directly selectable. Three custom WAV curves can also be stored internally, or curves can be loaded through the optional memory card or a digital interface.

Which values does the source measure?

Measurements include RMS, DC and peak voltage and current as well as active, reactive and apparent power, power factor, crest factor and frequency.

Can the EAC-S simulate a single-phase mains supply?

Yes. Voltage, frequency and waveform are programmable, and a DC component can be superimposed. The selected operating point must remain within the voltage, current and power limits.

Can defined voltage interruptions be generated?

Yes. The DIP option disables the output for a defined number of half-periods. DIP and the time-dependent GATE and pulse functions require a digital interface.

Can a test sequence run independently without a PC?

With the optional SD card, scripts containing up to 100 commands can be executed and measurements can be logged. This supports repeatable standalone sequences.

Technical consultation and project enquiry

To select the correct EAC-S configuration, please provide power, AC and DC voltage range, maximum current, frequency, waveform and intended test duration. Add requirements for DC offset, voltage interruptions, external signals, synchronization, interfaces, data logging, interlock, mains connection and installation space.

Discuss your EAC-S project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly