Voltage, current limit and phase angle can be set together or individually for L1, L2 and L3.
EAC-3S – Linear Three-Phase AC/DC Power Supply up to 30 kVA
For three-phase grid simulation and equipment testing with freely programmable waveforms and low distortion.
The EAC-3S is a linearly regulated three-phase AC source for simulating single- and three-phase grids. Twelve power classes cover a total output from 750 VA to 30 kVA. Each phase provides 0–300 VAC or 0–425 VDC as standard, with optional ranges up to 700 VAC or 1,000 VDC.
Sine, square, triangle and three non-volatile user-defined waveforms support repeatable grid and disturbance profiles.
The source measures RMS, DC and peak values as well as active, reactive and apparent power, power factor and crest factor.
With the optional SD card, script control and data logging combine programmed sequences with local measurement recording.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
EAC-3S 250 Linear 3-ph. AC/DC source, 3 × 250 VA, 300 V AC L-N, 425 V DC, 3 × 3 A, 3 × 4U, 1–500 Hz
|
Current [A]
9
|
Power [P]
250
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 500 Linear 3-ph. AC/DC source, 3 × 500 VA, 300 V AC L-N, 425 V DC, 3 × 6 A, 3 × 4U, 1–500 Hz
|
Current [A]
18
|
Power [P]
500
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 1000 Linear 3-ph. AC/DC source, 3 × 1 kVA, 300 V AC L-N, 425 V DC, 3 × 10 A, 3 × 6U, 1–500 Hz
|
Current [A]
30
|
Power [P]
1000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 2000 Linear 3-ph. AC/DC source, 3 × 2 kVA, 300 V AC L-N, 425 V DC, 3 × 15 A, 3 × 6U, 1–500 Hz
|
Current [A]
45
|
Power [P]
2000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 3000 Linear 3-ph. AC/DC source, 3 × 3 kVA, 300 V AC L-N, 425 V DC, 3 × 20 A, 3 × 10U, 1–500 Hz
|
Current [A]
60
|
Power [P]
3000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 4000 Linear 3-ph. AC/DC source, 3 × 4 kVA, 300 V AC L-N, 425 V DC, 3 × 30 A, 3 × 16U, 1–500 Hz
|
Current [A]
90
|
Power [P]
4000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 5000 Linear 3-ph. AC/DC source, 3 × 5 kVA, 300 V AC L-N, 425 V DC, 3 × 35 A, 3 × 16U, 1–500 Hz
|
Current [A]
105
|
Power [P]
5000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 6000 Linear 3-ph. AC/DC source, 3 × 6 kVA, 300 V AC L-N, 425 V DC, 3 × 40 A, 3 × 16U, 1–500 Hz
|
Current [A]
120
|
Power [P]
6000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 7000 Linear 3-ph. AC/DC source, 3 × 7 kVA, 300 V AC L-N, 425 V DC, 3 × 50 A, 3 × 20U, 1–500 Hz
|
Current [A]
150
|
Power [P]
7000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 8000 Linear 3-ph. AC/DC source, 3 × 8 kVA, 300 V AC L-N, 425 V DC, 3 × 60 A, 3 × 20U, 1–500 Hz
|
Current [A]
180
|
Power [P]
8000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 9000 Linear 3-ph. AC/DC source, 3 × 9 kVA, 300 V AC L-N, 425 V DC, 3 × 70 A, 3 × 25U, 1–500 Hz
|
Current [A]
210
|
Power [P]
9000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
|
Description
EAC-3S 10000 Linear 3-ph. AC/DC source, 3 × 10 kVA, 300 V AC L-N, 425 V DC, 3 × 80 A, 3 × 25U, 1–500 Hz
|
Current [A]
240
|
Power [P]
10000
|
Voltage [V]
300
|
Technical Data
Height
Product category
AC Power Supply
Type of AC source
Current-controlled CC
Single-/Three-phase
EAC-3S overview
The EAC-3S is a three-phase, linearly regulated AC power source for simulating single- and three-phase grids. The system consists of three coupled phase units, and the EAC-3S 250 through EAC-3S 10000 models cover a total output from 750 VA to 30 kVA. The standard version provides 0–300 VAC or 0–425 VDC per phase; optional voltage ranges extend to 700 VAC or 1,000 VDC. Sine, square and triangle signals as well as user-defined waveforms are generated from a periodic value table and reproduced by analog power amplifiers. AC, DC and combined AC+DC operation support balanced grids as well as targeted offset and unbalance profiles. Operation and measurement display are available from the graphical front panel, while optional analog and digital interfaces, SD-card functions, and synchronization inputs and outputs support automated test systems.
Key benefits
Linear output stage
Analog power amplifiers reproduce the stored waveform. Total harmonic distortion is specified as 0.15% at maximum power, 110/220 V, 50/60 Hz and a resistive load.
Individual phase control
Setpoints and phase angles can be adjusted separately for L1, L2 and L3. A fixed three-phase set of 0°, 120° and 240° is directly selectable.
Combine AC and offset
A positive or negative DC component can be superimposed on the AC waveform, generating defined mixed voltages without an additional source.
Store custom waveforms
Waveforms with 3,600 samples and 16-bit data can be loaded via SD card or digital interface; three internal non-volatile memory locations retain the data.
Capture electrical quantities
RMS, DC and peak values as well as power quantities and factors are available on the source and through optional remote control for evaluation.
Operate without a control PC
Optional scripts process up to 100 commands. Combined with the data logger, they create autonomous sequences with measurement records on the memory card.
Linear technology compared with switch-mode sources
The EAC-3S uses a linear output stage in which an analog power amplifier continuously reproduces the specified waveform at the output. In contrast, switch-mode sources generate their output voltage by rapidly switching the power semiconductors. Linear technology supports a particularly clean waveform with low levels of switching-related high-frequency components, making it especially suitable for sensitive measurement, development and testing applications. Switch-mode sources generally offer higher efficiency, lower heat dissipation and more compact dimensions. The preferred technology therefore depends on whether signal quality or energy efficiency and power density are the primary consideration.
Operating principle of the linear three-phase AC source
After galvanic isolation, the supply voltage is rectified and powers an analog power amplifier. Its setpoint signal comes from a table containing one complete period of a fixed standard signal or a user-defined waveform. The output voltage follows this table, the selected amplitude and any enabled DC offset.
In the EAC-3S, the three phase units are coupled at the rear. All three output neutral conductors are connected for three-phase operation. Control can apply common values to all phases or set voltage, current limit and phase angle separately for L1, L2 and L3. If the selected current limit is exceeded, the voltage source reduces its amplitude.
Power range and model overview
The power designation represents three equal phase power ratings. Current and voltage range apply to each phase. The following standard models use 0–300 VAC or 0–425 VDC per phase; different voltage ranges and special versions are options.
| Model | Total output | Output per phase | Voltage per phase | Maximum current per phase | Dimensions |
|---|---|---|---|---|---|
| EAC-3S 250 | 750 VA | 3 × 250 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–3 A | 3 × 19-inch × 4U × 434.5 mm |
| EAC-3S 500 | 1,500 VA | 3 × 500 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–6 A | 3 × 19-inch × 4U × 434.5 mm |
| EAC-3S 1000 | 3,000 VA | 3 × 1,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–10 A | 3 × 19-inch × 6U × 434.5 mm |
| EAC-3S 2000 | 6,000 VA | 3 × 2,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–15 A | 3 × 19-inch × 6U × 434.5 mm |
| EAC-3S 3000 | 9,000 VA | 3 × 3,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–20 A | 3 × 19-inch × 10U × 434.5 mm |
| EAC-3S 4000 | 12,000 VA | 3 × 4,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–30 A | 3 × 19-inch × 16U × 600 mm |
| EAC-3S 5000 | 15,000 VA | 3 × 5,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–35 A | 3 × 19-inch × 16U × 600 mm |
| EAC-3S 6000 | 18,000 VA | 3 × 6,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–40 A | 3 × 19-inch × 16U × 600 mm |
| EAC-3S 7000 | 21,000 VA | 3 × 7,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–50 A | 3 × 19-inch × 20U × 800 mm |
| EAC-3S 8000 | 24,000 VA | 3 × 8,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–60 A | 3 × 19-inch × 20U × 800 mm |
| EAC-3S 9000 | 27,000 VA | 3 × 9,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–70 A | 3 × 19-inch × 25U × 800 mm |
| EAC-3S 10000 | 30,000 VA | 3 × 10,000 VA | 3 × 0–300 VAC / 0–425 VDC | 3 × 0–80 A | 3 × 19-inch × 25U × 800 mm |
Optional output ranges: ../V500 extends each phase to 0–500 VAC or 0–700 VDC with a 40% reduction in maximum current. ../V700 extends the range to 0–700 VAC or 0–1,000 VDC with a 50% reduction in maximum current. Special versions are available on request.
Regulation, signal quality and accuracy
| Parameter | Value | Condition or classification |
|---|---|---|
| Line regulation | 0.10% | Static output regulation |
| Load regulation | 0.10% | Static output regulation |
| Dynamic regulation | 5 periods | Regulating response after a change |
| Ripple | 0.3% | At 50 Hz |
| Total harmonic distortion | 0.15% | At maximum power, 110/220 V, 50/60 Hz and a resistive load |
| AC/DC voltage programming accuracy | 100 mV | Per voltage setpoint |
| Current programming accuracy | 1 mA / 10 mA | Below 10 A / from 10 A |
| Frequency programming accuracy | 0.1 Hz | Variable frequency setting |
| Activation phase programming accuracy | 0.1° | Phase-related setting |
Operating modes and programmable functions
| Function | Operation | Use in the test system |
|---|---|---|
| AC / DC / AC+DC | AC amplitude, DC offset and current limit are set; the DC component can be positive or negative. | Generate pure AC and DC voltage or superimposed grid waveforms from one source. |
| Sine / square / triangle | Three fixed signals are selected directly from the front panel or by remote control. | Configure basic grid and functional tests quickly. |
| User-defined WAV waveform | One period contains 3,600 samples at 16 bits; three internal memories or direct output are available. | Reproduce custom periodic disturbances and waveforms. |
| Variable frequency | Adjustable from 0.1 Hz to the device-specific maximum; up to 500 Hz as standard, extended with ../F1000 and ../F2000. | Adapt test frequency to grid, laboratory or component scenarios. |
| Phase control | Common or individual phase values and a fixed set of 0°, 120° and 240°. | Create balanced and intentionally unbalanced three-phase grids. |
| DIP / GATE / APuls | Optional output interruption, activation and pulse sequence with timing by period or half-period; a digital interface is required. | Automate short interruptions and defined switching sequences. |
| External oscillator | An optional ±10 V signal is amplified; delay is adjustable up to 70 ms. | Apply an external reference waveform to the power amplifier. |
Typical applications
The EAC-3S generates defined three-phase supply and disturbance profiles for laboratories, industry and service engineering.
Single- and three-phase grid simulation
Voltage, frequency and phase angle are specified per phase. This enables balanced grids and controlled unbalance profiles for connected devices under test.
Voltage dips and phase failure
Script commands and the optional DIP function change or interrupt individual phase signals on a timed basis to reproduce voltage dips and phase failures.
Testing with custom waveforms
WAV files reproduce custom periodic profiles. Amplitude, frequency and DC offset adapt the signal to the specific test task.
Synchronized measurement setups
The optional sync input locks the output waveform to an external source; the optional sync output triggers measuring instruments in the test system.
Autonomous test fields
Script operation and data logging on the optional SD card execute test sequences and record operating values at adjustable intervals.
Interfaces, measurement and automation
| Equipment | Status | Function |
|---|---|---|
| Graphical front panel | Standard | Set setpoints, waveform, frequency and phase; display measurement and status values; save ten configurations. |
| RS232, RS485, IEEE488, LAN, USB | Optional | ASCII-based remote control, phase-specific setpoints, and queries of measured and status values. |
| Galvanically isolated analog interface | Optional, 0–5 V or 0–10 V | Set voltage, current and frequency by analog signals and monitor selected measured values. |
| SD card slot | Optional | Load user waveforms, execute scripts with up to 100 commands and log measurement data. |
| Sync input / sync output | Each optional | Synchronize the output with an external source or trigger external measuring instruments. |
| External oscillator input | Optional | Amplify an external ±10 V signal up to 1 kHz and shift it in time. |
| Interlock input | Optional | External release or safety shutdown of the power transformer; it does not isolate the output. |
Available measurements include RMS, DC and peak values of voltage and current, active, reactive and apparent power, power factor and crest factor. Measurement channels are assigned by phase in the three-phase version.
Installation and infrastructure
| Feature | Implementation or requirement |
|---|---|
| Mains input versions | Versions for 230 VAC, 400 VAC, 3 × 208 VAC, 3 × 400 VAC or 3 × 480 VAC; each ±10% according to the option code. |
| Input frequency | 47–63 Hz |
| Three-phase wiring | Couple the phase units using the intended rear cables and connect all three output neutral conductors. |
| Cooling | Fan cooling; keep airflow paths clear. |
| Operating temperature | 0–50°C |
| Storage | −20 to +70°C |
| Ambient conditions | Relative humidity below 80%; operating altitude below 2,000 m. |
| Form factor and weight | Model-dependent 19-inch configurations; 90–1,200 kg. |
System planning: The mains connection, protective earth, cabling, cooling and installation space must be designed for the selected option and power configuration. Verify that the nameplate and available input voltage match before commissioning.
Protection and safety functions
The output regulator limits amplitude when the selected current is exceeded. The source monitors overtemperature and overpower conditions; overload and shutdown states are shown on the display and available through status queries. Standby deactivates the output electronically.
The EAC-3S is a protection class I device with galvanic isolation between input and output. Protective earth must be connected. The optional interlock switches off the power transformer on the primary side by means of a contactor, but this is not output isolation according to VDE. The source is intended for trained personnel in controlled laboratory and industrial environments.
EAC-3S FAQ
How is the appropriate power class selected?
The required power and maximum current per phase are decisive. The model designation gives the phase power; EAC-3S 2000, for example, means 3 × 2,000 VA and therefore 6,000 VA total output.
Do voltage and current apply to the complete system?
No. Voltage and maximum current apply per phase. The model table therefore shows both total three-phase power and the corresponding phase value.
Are 700 VAC and 2,000 Hz standard?
No. 700 VAC per phase requires the ../V700 option and reduces maximum current by 50%. Operation up to 2,000 Hz requires the ../F2000 frequency option.
Can the source output a custom waveform?
Yes. A waveform contains 3,600 16-bit samples. It can be loaded through an SD card or digital interface into three internal memories or sent directly to the output.
Can it simulate voltage dips and phase failures?
Yes. Scripts can combine phase-specific setpoints and delays; short interruptions are also available through the optional DIP function with a digital interface.
Can a test sequence run without a control PC?
With the optional SD card, scripts containing up to 100 commands can run while the data logger saves measurements. This creates a stand-alone test sequence.
Can the output waveform synchronize to an external source?
With the optional sync input, the output waveform synchronizes to the rising edge of an external signal. A separately optional sync output can trigger measuring instruments.
Does the interlock galvanically isolate the output?
No. The optional external release switches off the power transformer on the primary side, but it is not output isolation according to VDE.
Technical consultation and project enquiry
To configure an EAC-3S, we need the voltage, current and power per phase, the required frequency and waveform range, and requirements for phase angle, DC offset, interfaces, synchronization and autonomous test sequences. Please also include the available mains voltage and planned installation environment.