Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
EAC-3S 250

Description
EAC-3S 250 Linear 3-ph. AC/DC source, 3 × 250 VA, 300 V AC L-N, 425 V DC, 3 × 3 A, 3 × 4U, 1–500 Hz
Current [A]
9
Power [P]
250
Voltage [V]
300
EAC-3S 250
EAC-3S 250 Linear 3-ph. AC/DC source, 3 × 250 VA, 300 V AC L-N, 425 V DC, 3 × 3 A, 3 × 4U, 1–500 Hz
9
250
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 500

Description
EAC-3S 500 Linear 3-ph. AC/DC source, 3 × 500 VA, 300 V AC L-N, 425 V DC, 3 × 6 A, 3 × 4U, 1–500 Hz
Current [A]
18
Power [P]
500
Voltage [V]
300
EAC-3S 500
EAC-3S 500 Linear 3-ph. AC/DC source, 3 × 500 VA, 300 V AC L-N, 425 V DC, 3 × 6 A, 3 × 4U, 1–500 Hz
18
500
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 1000

Description
EAC-3S 1000 Linear 3-ph. AC/DC source, 3 × 1 kVA, 300 V AC L-N, 425 V DC, 3 × 10 A, 3 × 6U, 1–500 Hz
Current [A]
30
Power [P]
1000
Voltage [V]
300
EAC-3S 1000
EAC-3S 1000 Linear 3-ph. AC/DC source, 3 × 1 kVA, 300 V AC L-N, 425 V DC, 3 × 10 A, 3 × 6U, 1–500 Hz
30
1000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 2000

Description
EAC-3S 2000 Linear 3-ph. AC/DC source, 3 × 2 kVA, 300 V AC L-N, 425 V DC, 3 × 15 A, 3 × 6U, 1–500 Hz
Current [A]
45
Power [P]
2000
Voltage [V]
300
EAC-3S 2000
EAC-3S 2000 Linear 3-ph. AC/DC source, 3 × 2 kVA, 300 V AC L-N, 425 V DC, 3 × 15 A, 3 × 6U, 1–500 Hz
45
2000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 3000

Description
EAC-3S 3000 Linear 3-ph. AC/DC source, 3 × 3 kVA, 300 V AC L-N, 425 V DC, 3 × 20 A, 3 × 10U, 1–500 Hz
Current [A]
60
Power [P]
3000
Voltage [V]
300
EAC-3S 3000
EAC-3S 3000 Linear 3-ph. AC/DC source, 3 × 3 kVA, 300 V AC L-N, 425 V DC, 3 × 20 A, 3 × 10U, 1–500 Hz
60
3000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 4000

Description
EAC-3S 4000 Linear 3-ph. AC/DC source, 3 × 4 kVA, 300 V AC L-N, 425 V DC, 3 × 30 A, 3 × 16U, 1–500 Hz
Current [A]
90
Power [P]
4000
Voltage [V]
300
EAC-3S 4000
EAC-3S 4000 Linear 3-ph. AC/DC source, 3 × 4 kVA, 300 V AC L-N, 425 V DC, 3 × 30 A, 3 × 16U, 1–500 Hz
90
4000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 5000

Description
EAC-3S 5000 Linear 3-ph. AC/DC source, 3 × 5 kVA, 300 V AC L-N, 425 V DC, 3 × 35 A, 3 × 16U, 1–500 Hz
Current [A]
105
Power [P]
5000
Voltage [V]
300
EAC-3S 5000
EAC-3S 5000 Linear 3-ph. AC/DC source, 3 × 5 kVA, 300 V AC L-N, 425 V DC, 3 × 35 A, 3 × 16U, 1–500 Hz
105
5000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 6000

Description
EAC-3S 6000 Linear 3-ph. AC/DC source, 3 × 6 kVA, 300 V AC L-N, 425 V DC, 3 × 40 A, 3 × 16U, 1–500 Hz
Current [A]
120
Power [P]
6000
Voltage [V]
300
EAC-3S 6000
EAC-3S 6000 Linear 3-ph. AC/DC source, 3 × 6 kVA, 300 V AC L-N, 425 V DC, 3 × 40 A, 3 × 16U, 1–500 Hz
120
6000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 7000

Description
EAC-3S 7000 Linear 3-ph. AC/DC source, 3 × 7 kVA, 300 V AC L-N, 425 V DC, 3 × 50 A, 3 × 20U, 1–500 Hz
Current [A]
150
Power [P]
7000
Voltage [V]
300
EAC-3S 7000
EAC-3S 7000 Linear 3-ph. AC/DC source, 3 × 7 kVA, 300 V AC L-N, 425 V DC, 3 × 50 A, 3 × 20U, 1–500 Hz
150
7000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 8000

Description
EAC-3S 8000 Linear 3-ph. AC/DC source, 3 × 8 kVA, 300 V AC L-N, 425 V DC, 3 × 60 A, 3 × 20U, 1–500 Hz
Current [A]
180
Power [P]
8000
Voltage [V]
300
EAC-3S 8000
EAC-3S 8000 Linear 3-ph. AC/DC source, 3 × 8 kVA, 300 V AC L-N, 425 V DC, 3 × 60 A, 3 × 20U, 1–500 Hz
180
8000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 9000

Description
EAC-3S 9000 Linear 3-ph. AC/DC source, 3 × 9 kVA, 300 V AC L-N, 425 V DC, 3 × 70 A, 3 × 25U, 1–500 Hz
Current [A]
210
Power [P]
9000
Voltage [V]
300
EAC-3S 9000
EAC-3S 9000 Linear 3-ph. AC/DC source, 3 × 9 kVA, 300 V AC L-N, 425 V DC, 3 × 70 A, 3 × 25U, 1–500 Hz
210
9000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S 10000

Description
EAC-3S 10000 Linear 3-ph. AC/DC source, 3 × 10 kVA, 300 V AC L-N, 425 V DC, 3 × 80 A, 3 × 25U, 1–500 Hz
Current [A]
240
Power [P]
10000
Voltage [V]
300
EAC-3S 10000
EAC-3S 10000 Linear 3-ph. AC/DC source, 3 × 10 kVA, 300 V AC L-N, 425 V DC, 3 × 80 A, 3 × 25U, 1–500 Hz
240
10000
300
Linear 3-ph AC Source

Technical Data

Height

Product category

AC Power Supply

Type of AC source

Current-controlled CC

Single-/Three-phase

EAC-3S overview

The EAC-3S is a three-phase, linearly regulated AC power source for simulating single- and three-phase grids. The system consists of three coupled phase units, and the EAC-3S 250 through EAC-3S 10000 models cover a total output from 750 VA to 30 kVA. The standard version provides 0–300 VAC or 0–425 VDC per phase; optional voltage ranges extend to 700 VAC or 1,000 VDC. Sine, square and triangle signals as well as user-defined waveforms are generated from a periodic value table and reproduced by analog power amplifiers. AC, DC and combined AC+DC operation support balanced grids as well as targeted offset and unbalance profiles. Operation and measurement display are available from the graphical front panel, while optional analog and digital interfaces, SD-card functions, and synchronization inputs and outputs support automated test systems.

Key benefits

Linear output stage

Analog power amplifiers reproduce the stored waveform. Total harmonic distortion is specified as 0.15% at maximum power, 110/220 V, 50/60 Hz and a resistive load.

Individual phase control

Setpoints and phase angles can be adjusted separately for L1, L2 and L3. A fixed three-phase set of 0°, 120° and 240° is directly selectable.

Combine AC and offset

A positive or negative DC component can be superimposed on the AC waveform, generating defined mixed voltages without an additional source.

Store custom waveforms

Waveforms with 3,600 samples and 16-bit data can be loaded via SD card or digital interface; three internal non-volatile memory locations retain the data.

Capture electrical quantities

RMS, DC and peak values as well as power quantities and factors are available on the source and through optional remote control for evaluation.

Operate without a control PC

Optional scripts process up to 100 commands. Combined with the data logger, they create autonomous sequences with measurement records on the memory card.

Linear technology compared with switch-mode sources

The EAC-3S uses a linear output stage in which an analog power amplifier continuously reproduces the specified waveform at the output. In contrast, switch-mode sources generate their output voltage by rapidly switching the power semiconductors. Linear technology supports a particularly clean waveform with low levels of switching-related high-frequency components, making it especially suitable for sensitive measurement, development and testing applications. Switch-mode sources generally offer higher efficiency, lower heat dissipation and more compact dimensions. The preferred technology therefore depends on whether signal quality or energy efficiency and power density are the primary consideration.

Operating principle of the linear three-phase AC source

After galvanic isolation, the supply voltage is rectified and powers an analog power amplifier. Its setpoint signal comes from a table containing one complete period of a fixed standard signal or a user-defined waveform. The output voltage follows this table, the selected amplitude and any enabled DC offset.

In the EAC-3S, the three phase units are coupled at the rear. All three output neutral conductors are connected for three-phase operation. Control can apply common values to all phases or set voltage, current limit and phase angle separately for L1, L2 and L3. If the selected current limit is exceeded, the voltage source reduces its amplitude.

Power range and model overview

The power designation represents three equal phase power ratings. Current and voltage range apply to each phase. The following standard models use 0–300 VAC or 0–425 VDC per phase; different voltage ranges and special versions are options.

ModelTotal outputOutput per phaseVoltage per phaseMaximum current per phaseDimensions
EAC-3S 250750 VA3 × 250 VA3 × 0–300 VAC / 0–425 VDC3 × 0–3 A3 × 19-inch × 4U × 434.5 mm
EAC-3S 5001,500 VA3 × 500 VA3 × 0–300 VAC / 0–425 VDC3 × 0–6 A3 × 19-inch × 4U × 434.5 mm
EAC-3S 10003,000 VA3 × 1,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–10 A3 × 19-inch × 6U × 434.5 mm
EAC-3S 20006,000 VA3 × 2,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–15 A3 × 19-inch × 6U × 434.5 mm
EAC-3S 30009,000 VA3 × 3,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–20 A3 × 19-inch × 10U × 434.5 mm
EAC-3S 400012,000 VA3 × 4,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–30 A3 × 19-inch × 16U × 600 mm
EAC-3S 500015,000 VA3 × 5,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–35 A3 × 19-inch × 16U × 600 mm
EAC-3S 600018,000 VA3 × 6,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–40 A3 × 19-inch × 16U × 600 mm
EAC-3S 700021,000 VA3 × 7,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–50 A3 × 19-inch × 20U × 800 mm
EAC-3S 800024,000 VA3 × 8,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–60 A3 × 19-inch × 20U × 800 mm
EAC-3S 900027,000 VA3 × 9,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–70 A3 × 19-inch × 25U × 800 mm
EAC-3S 1000030,000 VA3 × 10,000 VA3 × 0–300 VAC / 0–425 VDC3 × 0–80 A3 × 19-inch × 25U × 800 mm

Optional output ranges: ../V500 extends each phase to 0–500 VAC or 0–700 VDC with a 40% reduction in maximum current. ../V700 extends the range to 0–700 VAC or 0–1,000 VDC with a 50% reduction in maximum current. Special versions are available on request.

Regulation, signal quality and accuracy

ParameterValueCondition or classification
Line regulation0.10%Static output regulation
Load regulation0.10%Static output regulation
Dynamic regulation5 periodsRegulating response after a change
Ripple0.3%At 50 Hz
Total harmonic distortion0.15%At maximum power, 110/220 V, 50/60 Hz and a resistive load
AC/DC voltage programming accuracy100 mVPer voltage setpoint
Current programming accuracy1 mA / 10 mABelow 10 A / from 10 A
Frequency programming accuracy0.1 HzVariable frequency setting
Activation phase programming accuracy0.1°Phase-related setting

Operating modes and programmable functions

FunctionOperationUse in the test system
AC / DC / AC+DCAC amplitude, DC offset and current limit are set; the DC component can be positive or negative.Generate pure AC and DC voltage or superimposed grid waveforms from one source.
Sine / square / triangleThree fixed signals are selected directly from the front panel or by remote control.Configure basic grid and functional tests quickly.
User-defined WAV waveformOne period contains 3,600 samples at 16 bits; three internal memories or direct output are available.Reproduce custom periodic disturbances and waveforms.
Variable frequencyAdjustable from 0.1 Hz to the device-specific maximum; up to 500 Hz as standard, extended with ../F1000 and ../F2000.Adapt test frequency to grid, laboratory or component scenarios.
Phase controlCommon or individual phase values and a fixed set of 0°, 120° and 240°.Create balanced and intentionally unbalanced three-phase grids.
DIP / GATE / APulsOptional output interruption, activation and pulse sequence with timing by period or half-period; a digital interface is required.Automate short interruptions and defined switching sequences.
External oscillatorAn optional ±10 V signal is amplified; delay is adjustable up to 70 ms.Apply an external reference waveform to the power amplifier.

Typical applications

The EAC-3S generates defined three-phase supply and disturbance profiles for laboratories, industry and service engineering.

Single- and three-phase grid simulation

Voltage, frequency and phase angle are specified per phase. This enables balanced grids and controlled unbalance profiles for connected devices under test.

Voltage dips and phase failure

Script commands and the optional DIP function change or interrupt individual phase signals on a timed basis to reproduce voltage dips and phase failures.

Testing with custom waveforms

WAV files reproduce custom periodic profiles. Amplitude, frequency and DC offset adapt the signal to the specific test task.

Synchronized measurement setups

The optional sync input locks the output waveform to an external source; the optional sync output triggers measuring instruments in the test system.

Autonomous test fields

Script operation and data logging on the optional SD card execute test sequences and record operating values at adjustable intervals.

Interfaces, measurement and automation

EquipmentStatusFunction
Graphical front panelStandardSet setpoints, waveform, frequency and phase; display measurement and status values; save ten configurations.
RS232, RS485, IEEE488, LAN, USBOptionalASCII-based remote control, phase-specific setpoints, and queries of measured and status values.
Galvanically isolated analog interfaceOptional, 0–5 V or 0–10 VSet voltage, current and frequency by analog signals and monitor selected measured values.
SD card slotOptionalLoad user waveforms, execute scripts with up to 100 commands and log measurement data.
Sync input / sync outputEach optionalSynchronize the output with an external source or trigger external measuring instruments.
External oscillator inputOptionalAmplify an external ±10 V signal up to 1 kHz and shift it in time.
Interlock inputOptionalExternal release or safety shutdown of the power transformer; it does not isolate the output.

Available measurements include RMS, DC and peak values of voltage and current, active, reactive and apparent power, power factor and crest factor. Measurement channels are assigned by phase in the three-phase version.

Installation and infrastructure

FeatureImplementation or requirement
Mains input versionsVersions for 230 VAC, 400 VAC, 3 × 208 VAC, 3 × 400 VAC or 3 × 480 VAC; each ±10% according to the option code.
Input frequency47–63 Hz
Three-phase wiringCouple the phase units using the intended rear cables and connect all three output neutral conductors.
CoolingFan cooling; keep airflow paths clear.
Operating temperature0–50°C
Storage−20 to +70°C
Ambient conditionsRelative humidity below 80%; operating altitude below 2,000 m.
Form factor and weightModel-dependent 19-inch configurations; 90–1,200 kg.

System planning: The mains connection, protective earth, cabling, cooling and installation space must be designed for the selected option and power configuration. Verify that the nameplate and available input voltage match before commissioning.

Protection and safety functions

The output regulator limits amplitude when the selected current is exceeded. The source monitors overtemperature and overpower conditions; overload and shutdown states are shown on the display and available through status queries. Standby deactivates the output electronically.

The EAC-3S is a protection class I device with galvanic isolation between input and output. Protective earth must be connected. The optional interlock switches off the power transformer on the primary side by means of a contactor, but this is not output isolation according to VDE. The source is intended for trained personnel in controlled laboratory and industrial environments.

EAC-3S FAQ

How is the appropriate power class selected?

The required power and maximum current per phase are decisive. The model designation gives the phase power; EAC-3S 2000, for example, means 3 × 2,000 VA and therefore 6,000 VA total output.

Do voltage and current apply to the complete system?

No. Voltage and maximum current apply per phase. The model table therefore shows both total three-phase power and the corresponding phase value.

Are 700 VAC and 2,000 Hz standard?

No. 700 VAC per phase requires the ../V700 option and reduces maximum current by 50%. Operation up to 2,000 Hz requires the ../F2000 frequency option.

Can the source output a custom waveform?

Yes. A waveform contains 3,600 16-bit samples. It can be loaded through an SD card or digital interface into three internal memories or sent directly to the output.

Can it simulate voltage dips and phase failures?

Yes. Scripts can combine phase-specific setpoints and delays; short interruptions are also available through the optional DIP function with a digital interface.

Can a test sequence run without a control PC?

With the optional SD card, scripts containing up to 100 commands can run while the data logger saves measurements. This creates a stand-alone test sequence.

Can the output waveform synchronize to an external source?

With the optional sync input, the output waveform synchronizes to the rising edge of an external signal. A separately optional sync output can trigger measuring instruments.

Does the interlock galvanically isolate the output?

No. The optional external release switches off the power transformer on the primary side, but it is not output isolation according to VDE.

Technical consultation and project enquiry

To configure an EAC-3S, we need the voltage, current and power per phase, the required frequency and waveform range, and requirements for phase angle, DC offset, interfaces, synchronization and autonomous test sequences. Please also include the available mains voltage and planned installation environment.

Discuss your EAC-3S project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly