Skip to main content Skip to search Skip to main navigation

Filter products

ART. NO.
Description
Current [A]
Power [P]
Voltage [V]
BSL 100-1000-200

Description
BSL 100-1000-200 Bidirectional DC source/load, 100 kW, 1000 V, 200 A, regenerative, M/S parallel scalable
Current [A]
200
Power [P]
100000
Voltage [V]
1000
BSL 100-1000-200
BSL 100-1000-200 Bidirectional DC source/load, 100 kW, 1000 V, 200 A, regenerative, M/S parallel scalable
200
100000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-1000-300

Description
BSL 100-1000-300 Bidirectional DC source/load, 100 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
Current [A]
300
Power [P]
100000
Voltage [V]
1000
BSL 100-1000-300
BSL 100-1000-300 Bidirectional DC source/load, 100 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
300
100000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-1000-400

Description
BSL 100-1000-400 Bidirectional DC source/load, 100 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
Current [A]
400
Power [P]
100000
Voltage [V]
1000
BSL 100-1000-400
BSL 100-1000-400 Bidirectional DC source/load, 100 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
400
100000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-1500-133

Description
BSL 100-1500-133 Bidirectional DC source/load, 100 kW, 1500 V, 133 A, regenerative, M/S parallel scalable
Current [A]
133
Power [P]
100000
Voltage [V]
1500
BSL 100-1500-133
BSL 100-1500-133 Bidirectional DC source/load, 100 kW, 1500 V, 133 A, regenerative, M/S parallel scalable
133
100000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-1500-200

Description
BSL 100-1500-200 Bidirektionale DC-Quelle/Last, 100 kW, 1500 V, 200 A, rückspeisefähig, M/S-parallel skalierbar
Current [A]
200
Power [P]
100000
Voltage [V]
1500
BSL 100-1500-200
BSL 100-1500-200 Bidirektionale DC-Quelle/Last, 100 kW, 1500 V, 200 A, rückspeisefähig, M/S-parallel skalierbar
200
100000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-1500-266

Description
BSL 100-1500-266 Bidirectional DC source/load, 100 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
Current [A]
266
Power [P]
100000
Voltage [V]
1500
BSL 100-1500-266
BSL 100-1500-266 Bidirectional DC source/load, 100 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
266
100000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-2000-100

Description
BSL 100-2000-100 Bidirectional DC source/load, 100 kW, 2000 V, 100 A, regenerative, M/S parallel scalable
Current [A]
100
Power [P]
100000
Voltage [V]
2000
BSL 100-2000-100
BSL 100-2000-100 Bidirectional DC source/load, 100 kW, 2000 V, 100 A, regenerative, M/S parallel scalable
100
100000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-2000-150

Description
BSL 100-2000-150 Bidirectional DC source/load, 100 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
Current [A]
150
Power [P]
100000
Voltage [V]
2000
BSL 100-2000-150
BSL 100-2000-150 Bidirectional DC source/load, 100 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
150
100000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 100-2000-200

Description
BSL 100-2000-200 Bidirectional DC source/load, 100 kW, 2000 V, 200 A, regenerative, M/S parallel scalable
Current [A]
200
Power [P]
100000
Voltage [V]
2000
BSL 100-2000-200
BSL 100-2000-200 Bidirectional DC source/load, 100 kW, 2000 V, 200 A, regenerative, M/S parallel scalable
200
100000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1000-300

Description
BSL 150-1000-300 Bidirectional DC source/load, 150 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
Current [A]
300
Power [P]
150000
Voltage [V]
1000
BSL 150-1000-300
BSL 150-1000-300 Bidirectional DC source/load, 150 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
300
150000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1000-450

Description
BSL 150-1000-450 Bidirectional DC source/load, 150 kW, 1000 V, 450 A, regenerative, M/S parallel scalable
Current [A]
450
Power [P]
150000
Voltage [V]
10000
BSL 150-1000-450
BSL 150-1000-450 Bidirectional DC source/load, 150 kW, 1000 V, 450 A, regenerative, M/S parallel scalable
450
150000
10000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1000-600

Description
BSL 150-1000-600 Bidirectional DC source/load, 150 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
Current [A]
600
Power [P]
150000
Voltage [V]
1000
BSL 150-1000-600
BSL 150-1000-600 Bidirectional DC source/load, 150 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
600
150000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1500-200

Description
BSL 150-1500-200 Bidirectional DC source/load, 150 kW, 1500 V, 200 A, regenerative, M/S parallel scalable
Current [A]
200
Power [P]
150000
Voltage [V]
1500
BSL 150-1500-200
BSL 150-1500-200 Bidirectional DC source/load, 150 kW, 1500 V, 200 A, regenerative, M/S parallel scalable
200
150000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1500-300

Description
BSL 150-1500-300 Bidirectional DC source/load, 150 kW, 1500 V, 300 A, regenerative, M/S parallel scalable
Current [A]
300
Power [P]
150000
Voltage [V]
1500
BSL 150-1500-300
BSL 150-1500-300 Bidirectional DC source/load, 150 kW, 1500 V, 300 A, regenerative, M/S parallel scalable
300
150000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-1500-400

Description
BSL 150-1500-400 Bidirectional DC source/load, 150 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
Current [A]
400
Power [P]
150000
Voltage [V]
1500
BSL 150-1500-400
BSL 150-1500-400 Bidirectional DC source/load, 150 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
400
150000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-2000-150

Description
BSL 150-2000-150 Bidirectional DC source/load, 150 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
Current [A]
150
Power [P]
150000
Voltage [V]
2000
BSL 150-2000-150
BSL 150-2000-150 Bidirectional DC source/load, 150 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
150
150000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-2000-225

Description
BSL 150-2000-225 Bidirectional DC source/load, 150 kW, 2000 V, 225 A, regenerative, M/S parallel scalable
Current [A]
225
Power [P]
150000
Voltage [V]
2000
BSL 150-2000-225
BSL 150-2000-225 Bidirectional DC source/load, 150 kW, 2000 V, 225 A, regenerative, M/S parallel scalable
225
150000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 150-2000-300

Description
BSL 150-2000-300 Bidirectional DC source/load, 150 kW, 2000 V, 300 A, regenerative, M/S parallel scalable
Current [A]
300
Power [P]
150000
Voltage [V]
2000
BSL 150-2000-300
BSL 150-2000-300 Bidirectional DC source/load, 150 kW, 2000 V, 300 A, regenerative, M/S parallel scalable
300
150000
2000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1000-400

Description
BSL 200-1000-400 Bidirectional DC source/load, 200 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
Current [A]
400
Power [P]
200000
Voltage [V]
1000
BSL 200-1000-400
BSL 200-1000-400 Bidirectional DC source/load, 200 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
400
200000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1000-600

Description
BSL 200-1000-600 Bidirectional DC source/load, 200 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
Current [A]
600
Power [P]
200000
Voltage [V]
1000
BSL 200-1000-600
BSL 200-1000-600 Bidirectional DC source/load, 200 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
600
200000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1000-800

Description
BSL 200-1000-800 Bidirectional DC source/load, 200 kW, 1000 V, 800 A, regenerative, M/S parallel scalable
Current [A]
800
Power [P]
200000
Voltage [V]
1000
BSL 200-1000-800
BSL 200-1000-800 Bidirectional DC source/load, 200 kW, 1000 V, 800 A, regenerative, M/S parallel scalable
800
200000
1000
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1500-266

Description
BSL 200-1500-266 Bidirectional DC source/load, 200 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
Current [A]
266
Power [P]
200000
Voltage [V]
1500
BSL 200-1500-266
BSL 200-1500-266 Bidirectional DC source/load, 200 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
266
200000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1500-400

Description
BSL 200-1500-400 Bidirectional DC source/load, 200 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
Current [A]
400
Power [P]
200000
Voltage [V]
1500
BSL 200-1500-400
BSL 200-1500-400 Bidirectional DC source/load, 200 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
400
200000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

BSL 200-1500-533

Description
BSL 200-1500-533 Bidirectional DC source/load, 200 kW, 1500 V, 533 A, regenerative, M/S parallel scalable
Current [A]
533
Power [P]
200000
Voltage [V]
1500
BSL 200-1500-533
BSL 200-1500-533 Bidirectional DC source/load, 200 kW, 1500 V, 533 A, regenerative, M/S parallel scalable
533
200000
1500
DC Source & DC Load

Technical Data

max. Current (± A)

max. power (± W)

max. voltage (V)

Product category

DC Bidirectional

DC Electronic Load

DC Power Supply

Source + Load

Source + Load

Type of DC Load

High Current

Regenerative

Load + Source

Type of DC source

Standard DC Source

Bidirectional

Source + Sink

Mehr laden...

BSL series overview

The BSL series is a bidirectional, IGBT PWM-controlled high-power DC source with regenerative sink operation. Individual systems are available with 100, 150, 200, 250 or 300 kW; the standard models cover 1,000, 1,500 and 2,000 V and rated currents up to 1,200 A. The automatic wide-range characteristic expands the usable voltage and current range within the rated power. In sink direction, the system operates as a regenerative DC electronic load and returns absorbed energy to the supply grid. CV, CC, CP and CR operation, programmable sequences, and software functions for battery, battery-test and PV applications support different test tasks on the same hardware platform. Operation is via a 12-inch TFT touch panel with a Windows-based GUI or remotely via LAN or RS485. Up to four systems of the same power rating can work in parallel in master-slave operation, reaching a total power of up to 1.2 MW.

Key benefits

Bidirectional power flow

Source and regenerative sink change over without interrupting operation; absorbed energy is returned to the grid.

Wide-range characteristic

The automatic characteristic provides different voltage and current combinations within the rated power.

Fast current transition

The documented current rise time is less than 5 ms; transition from -90 to +90% is less than 10 ms.

Parallel scaling

Up to four systems of the same power rating can be combined through the master-slave interface up to 1.2 MW.

Reproducible test sequences

Sequences define voltage, current, power, resistance, duration and transition time; parameter sets can be saved and imported.

Local and remote operation

Touch panel, LAN, RS485 and Modbus support manual control, test-bench automation, measurements and waveform recording.

How the bidirectional DC source works

The power electronics connect the three-phase supply grid to the DC device under test through filters, a transformer, and AC/DC and DC/DC stages. In source operation, the BSL series supplies the DUT with programmed voltage, current or power. When the DUT returns energy to the system, the BSL operates as a sink and feeds the absorbed power regeneratively back into the grid.

CV, CC, CP and CR provide constant-voltage, constant-current, constant-power and constant-resistance operation. Hardware limits constrain voltage, positive and regenerative current, and positive and regenerative power. Remote sense can compensate for voltage drop along the cables to the DUT.

Power range and standard models

The model designation follows the pattern BSL AAA-BBB-CCC/DDD: AAA identifies power in kW, BBB the voltage range in V, CCC the current range in A, and DDD the input configuration. The following overview contains every documented standard combination without the input suffix.

PowerVoltageStandard modelscorresponding current ranges
100 kW1,000 VBSL 100-1000-200, BSL 100-1000-300, BSL 100-1000-400200 / 300 / 400 A
100 kW1,500 VBSL 100-1500-133, BSL 100-1500-200, BSL 100-1500-266133 / 200 / 266 A
100 kW2,000 VBSL 100-2000-100, BSL 100-2000-150, BSL 100-2000-200100 / 150 / 200 A
150 kW1,000 VBSL 150-1000-300, BSL 150-1000-450, BSL 150-1000-600300 / 450 / 600 A
150 kW1,500 VBSL 150-1500-200, BSL 150-1500-300, BSL 150-1500-400200 / 300 / 400 A
150 kW2,000 VBSL 150-2000-150, BSL 150-2000-225, BSL 150-2000-300150 / 225 / 300 A
200 kW1,000 VBSL 200-1000-400, BSL 200-1000-600, BSL 200-1000-800400 / 600 / 800 A
200 kW1,500 VBSL 200-1500-266, BSL 200-1500-400, BSL 200-1500-533266 / 400 / 533 A
200 kW2,000 VBSL 200-2000-200, BSL 200-2000-300, BSL 200-2000-400200 / 300 / 400 A
250 kW1,000 VBSL 250-1000-500, BSL 250-1000-750, BSL 250-1000-1000500 / 750 / 1,000 A
250 kW1,500 VBSL 250-1500-333, BSL 250-1500-500, BSL 250-1500-666333 / 500 / 666 A
250 kW2,000 VBSL 250-2000-250, BSL 250-2000-375, BSL 250-2000-500250 / 375 / 500 A
300 kW1,000 VBSL 300-1000-600, BSL 300-1000-900, BSL 300-1000-1200600 / 900 / 1,200 A
300 kW1,500 VBSL 300-1500-400, BSL 300-1500-600, BSL 300-1500-800400 / 600 / 800 A
300 kW2,000 VBSL 300-2000-300, BSL 300-2000-450, BSL 300-2000-600300 / 450 / 600 A
Important for system sizing: Maximum voltage and maximum current are not automatically available simultaneously from a wide-range source. Within the permitted characteristic, an operating point follows P = U × I; the appropriate variant must therefore be selected using voltage, current and power together.

Dynamics and regulation

CharacteristicValueMeaning
Current rise time< 5 msFast transition to the programmed current.
Current transition, -90 to +90%< 10 msShort changeover between sink and source direction.
Regulation time for 0 to 100% load change< 5 msResponse to a complete load transition.
Load regulation0.1% FSVoltage deviation between no-load and load conditions relative to full scale.
Line regulation0.1% FSStabilisation under changes in the grid supply.
Voltage ripple / stability0.2% FS / 0.2% FSDocumented output characteristics.
Output accuracy, voltage / power0.1% FS / 0.3% FSSeparate accuracy figures for voltage and power.
Resolution, voltage / current / power0.1 V / 0.1 A / 0.1 kWIncrement of the adjustable or displayed quantities.

Operating modes and programmable functions

FunctionOperationTypical benefit
CV / CC / CP / CRRegulates constant voltage, constant current, constant power or constant resistance.Defined source and load conditions for different DUTs.
Sequence operationPrograms operating points, dwell times, transition times and cycles; save and import as CSV.Repeatable profiles and endurance tests.
Battery simulationConfigures battery type, series/parallel arrangement, internal resistance, initial capacity and SOC; custom curves can be imported.Emulation of charge and discharge behaviour without a real battery.
Battery testCombines charge, discharge and rest steps with time and termination conditions.Cycle, capacity, charge and discharge testing of batteries and packs.
PV simulationGenerates I-V curves from temperature, irradiance, Uoc, Isc, Ump and Pmax; supports static and dynamic MPPT tests.Reproducible testing of PV inverters in accordance with EN 50530:2010.
Regenerative DC loadLoads the DUT in CC, CR, CV or CP operation and returns energy to the grid.Efficient testing of energy sources and power electronics.

Typical applications

Battery simulation

The bidirectional source electrically emulates different battery types, SOC, internal resistance, and series and parallel arrangements.

PV inverter and MPPT testing

Programmable I-V curves and static and dynamic MPPT sequences represent different irradiance and temperature conditions.

Regenerative load testing

Power supplies, fuel cells, charging equipment, inverters and other power electronics can be tested with regenerative load operation.

Interfaces, software and automation

EquipmentFunction
12-inch TFT touch panelWindows-based GUI for parameters, measurements, sequences, waveforms, status and fault display.
LANRemote control through a network; documented standard port 502.
RS485Remote control through a two-wire connection with signal ground; supports multi-drop links.
ModbusDocumented communication protocol for integration into automated test systems.
Programming commandsControl operating mode, output, limits and sequences, and query measurements, status and fault codes.
Waveform recordingRecords output voltage and current, displays real-time and historical waveforms, and stores data for later analysis.
Remote senseMeasures voltage at the DUT and compensates for cable drop within the system's regulation capability.
Master-slave interfaceCommunication between parallel systems of the same power rating.

Scaling and parallel operation

For higher total power, up to four BSL systems of the same power rating can be operated in parallel. Master-slave communication uses the designated fibre-optic and network connections; AC inputs and DC outputs are connected in parallel as specified for the installation. Four 300 kW systems provide the documented upper limit of 1.2 MW.

System-planning note: Parallel operation requires systems of the same power rating, the designated communication cabling, and AC/DC infrastructure sized for the total current and total power.

Installation and infrastructure

TopicDocumented configuration
Standard AC input3P+N+PE, 380 V L-L ±10%, 47 to 63 Hz.
Input configurationsModel variants /380, /400 and /480 for 380, 400 or 480 V L-L ±10%; 3P+N+PE or 3P+PE. Other inputs on request.
Grid characteristicsEfficiency ≥ 90%, power factor 0.95 and THDi ≤ 3%.
Cooling and protection ratingForced-air cooling and IP21.
Operating environment0 to 40°C, 20 to 90% relative humidity, non-condensing; indoor installation.
ClearanceProvide more than 600 mm clearance from walls or other equipment for ventilation.
Cabinet dimensionsDepending on the model, from 800 × 900 × 1,900 mm to 2,800 × 1,000 × 2,100 mm (W × D × H).
WeightDepending on the standard model, approximately 1,150 to 2,800 kg; wheel base below 1,400 kg, channel-steel base from 1,400 kg.

Protection and monitoring functions

Overvoltage

An adjustable overvoltage threshold switches off the power output when it is exceeded.

Overcurrent

Separate overcurrent protection supplements programmable current limits for source and regenerative directions.

Overpower

Power is monitored through an adjustable protection threshold and separate positive and regenerative limits.

Overtemperature

Temperature monitoring includes IGBT readings and initiates shutdown when a corresponding fault occurs.

Emergency-stop interface

A local emergency stop and an activatable external 24 V interface support integration into the system concept.

Status monitoring

Front indicators and the GUI report operating state, output status, subsystem faults and main-circuit faults.

BSL series FAQ

Can the BSL series deliver and absorb energy?

Yes. It operates as a programmable DC source or regenerative electronic load and returns absorbed energy to the grid.

Are maximum voltage and maximum current available simultaneously?

Only when the operating point is within the rated power and permitted wide-range characteristic. Voltage, current and power must be checked together.

How can total power be increased?

Up to four systems of the same power rating can operate in parallel in master-slave mode. The maximum documented total power is 1.2 MW.

Which regulation modes are available?

CV, CC, CP and CR regulate constant voltage, constant current, constant power or constant resistance.

How is the BSL series automated?

LAN, RS485, Modbus and programming commands provide remote control, limit setting, sequences, and measurement and status queries.

What is remote sense used for?

The feedback line measures voltage at the DUT so that the system can compensate for voltage drop along the connection cable.

Can the BSL series test battery packs?

Yes. Charge, discharge and rest steps with time or termination conditions support cycle, capacity, charge and discharge testing.

Can it simulate a battery?

Yes. Battery type, series/parallel arrangement, internal resistance, capacity and SOC are configurable, and custom simulation curves can be imported.

Is the BSL series suitable for PV inverter testing?

Yes. It generates PV I-V curves and supports static and dynamic MPPT tests in accordance with EN 50530:2010.

Technical consultation and project enquiry

Selecting a BSL configuration requires the target voltage range, source and sink current, continuous power, dynamic test sequence, AC grid connection, interfaces, and requirements for parallel operation and system integration.

Send us your project data for technical sizing of the appropriate BSL configuration.

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly