Seamless changeover between DC source and regenerative load, returning absorbed energy to the grid.
BSL – Bidirectional DC Power Supply with Energy Regeneration
For battery pack charging, discharging and cycling tests and battery system simulation in EV test benches.
The BSL series combines a bidirectional high-power DC source and a regenerative electronic load in one system. Automatic wide-range characteristics, ratings from 100 to 300 kW, and battery, PV and sequence functions support reproducible tests with changing power-flow direction.
High voltage at lower current or high current at lower voltage within the respective power characteristic.
Up to four systems of the same power rating can operate in parallel for high-power master-slave test benches.
GUI functions cover sequences, battery simulation, battery testing, PV simulation, measurements and stored waveforms.
Personal project consultation
Do you need support selecting the right power supply? Our technical specialists will provide personal advice tailored to your application.
Select the appropriate technical configuration or access product documentation directly.
|
Description
BSL 100-1000-200 Bidirectional DC source/load, 100 kW, 1000 V, 200 A, regenerative, M/S parallel scalable
|
Current [A]
200
|
Power [P]
100000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-1000-300 Bidirectional DC source/load, 100 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
|
Current [A]
300
|
Power [P]
100000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-1000-400 Bidirectional DC source/load, 100 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
|
Current [A]
400
|
Power [P]
100000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-1500-133 Bidirectional DC source/load, 100 kW, 1500 V, 133 A, regenerative, M/S parallel scalable
|
Current [A]
133
|
Power [P]
100000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-1500-200 Bidirektionale DC-Quelle/Last, 100 kW, 1500 V, 200 A, rückspeisefähig, M/S-parallel skalierbar
|
Current [A]
200
|
Power [P]
100000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-1500-266 Bidirectional DC source/load, 100 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
|
Current [A]
266
|
Power [P]
100000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-2000-100 Bidirectional DC source/load, 100 kW, 2000 V, 100 A, regenerative, M/S parallel scalable
|
Current [A]
100
|
Power [P]
100000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-2000-150 Bidirectional DC source/load, 100 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
|
Current [A]
150
|
Power [P]
100000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 100-2000-200 Bidirectional DC source/load, 100 kW, 2000 V, 200 A, regenerative, M/S parallel scalable
|
Current [A]
200
|
Power [P]
100000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1000-300 Bidirectional DC source/load, 150 kW, 1000 V, 300 A, regenerative, M/S parallel scalable
|
Current [A]
300
|
Power [P]
150000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1000-450 Bidirectional DC source/load, 150 kW, 1000 V, 450 A, regenerative, M/S parallel scalable
|
Current [A]
450
|
Power [P]
150000
|
Voltage [V]
10000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1000-600 Bidirectional DC source/load, 150 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
|
Current [A]
600
|
Power [P]
150000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1500-200 Bidirectional DC source/load, 150 kW, 1500 V, 200 A, regenerative, M/S parallel scalable
|
Current [A]
200
|
Power [P]
150000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1500-300 Bidirectional DC source/load, 150 kW, 1500 V, 300 A, regenerative, M/S parallel scalable
|
Current [A]
300
|
Power [P]
150000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-1500-400 Bidirectional DC source/load, 150 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
|
Current [A]
400
|
Power [P]
150000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-2000-150 Bidirectional DC source/load, 150 kW, 2000 V, 150 A, regenerative, M/S parallel scalable
|
Current [A]
150
|
Power [P]
150000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-2000-225 Bidirectional DC source/load, 150 kW, 2000 V, 225 A, regenerative, M/S parallel scalable
|
Current [A]
225
|
Power [P]
150000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 150-2000-300 Bidirectional DC source/load, 150 kW, 2000 V, 300 A, regenerative, M/S parallel scalable
|
Current [A]
300
|
Power [P]
150000
|
Voltage [V]
2000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1000-400 Bidirectional DC source/load, 200 kW, 1000 V, 400 A, regenerative, M/S parallel scalable
|
Current [A]
400
|
Power [P]
200000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1000-600 Bidirectional DC source/load, 200 kW, 1000 V, 600 A, regenerative, M/S parallel scalable
|
Current [A]
600
|
Power [P]
200000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1000-800 Bidirectional DC source/load, 200 kW, 1000 V, 800 A, regenerative, M/S parallel scalable
|
Current [A]
800
|
Power [P]
200000
|
Voltage [V]
1000
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1500-266 Bidirectional DC source/load, 200 kW, 1500 V, 266 A, regenerative, M/S parallel scalable
|
Current [A]
266
|
Power [P]
200000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1500-400 Bidirectional DC source/load, 200 kW, 1500 V, 400 A, regenerative, M/S parallel scalable
|
Current [A]
400
|
Power [P]
200000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
|
Description
BSL 200-1500-533 Bidirectional DC source/load, 200 kW, 1500 V, 533 A, regenerative, M/S parallel scalable
|
Current [A]
533
|
Power [P]
200000
|
Voltage [V]
1500
|
Technical Data
max. Current (± A)
max. power (± W)
max. voltage (V)
Product category
DC Bidirectional
DC Electronic Load
DC Power Supply
Source + Load
Source + Load
Type of DC Load
High Current
Regenerative
Load + Source
Type of DC source
Standard DC Source
Bidirectional
Source + Sink
BSL series overview
The BSL series is a bidirectional, IGBT PWM-controlled high-power DC source with regenerative sink operation. Individual systems are available with 100, 150, 200, 250 or 300 kW; the standard models cover 1,000, 1,500 and 2,000 V and rated currents up to 1,200 A. The automatic wide-range characteristic expands the usable voltage and current range within the rated power. In sink direction, the system operates as a regenerative DC electronic load and returns absorbed energy to the supply grid. CV, CC, CP and CR operation, programmable sequences, and software functions for battery, battery-test and PV applications support different test tasks on the same hardware platform. Operation is via a 12-inch TFT touch panel with a Windows-based GUI or remotely via LAN or RS485. Up to four systems of the same power rating can work in parallel in master-slave operation, reaching a total power of up to 1.2 MW.
Key benefits
Bidirectional power flow
Source and regenerative sink change over without interrupting operation; absorbed energy is returned to the grid.
Wide-range characteristic
The automatic characteristic provides different voltage and current combinations within the rated power.
Fast current transition
The documented current rise time is less than 5 ms; transition from -90 to +90% is less than 10 ms.
Parallel scaling
Up to four systems of the same power rating can be combined through the master-slave interface up to 1.2 MW.
Reproducible test sequences
Sequences define voltage, current, power, resistance, duration and transition time; parameter sets can be saved and imported.
Local and remote operation
Touch panel, LAN, RS485 and Modbus support manual control, test-bench automation, measurements and waveform recording.
How the bidirectional DC source works
The power electronics connect the three-phase supply grid to the DC device under test through filters, a transformer, and AC/DC and DC/DC stages. In source operation, the BSL series supplies the DUT with programmed voltage, current or power. When the DUT returns energy to the system, the BSL operates as a sink and feeds the absorbed power regeneratively back into the grid.
CV, CC, CP and CR provide constant-voltage, constant-current, constant-power and constant-resistance operation. Hardware limits constrain voltage, positive and regenerative current, and positive and regenerative power. Remote sense can compensate for voltage drop along the cables to the DUT.
Power range and standard models
The model designation follows the pattern BSL AAA-BBB-CCC/DDD: AAA identifies power in kW, BBB the voltage range in V, CCC the current range in A, and DDD the input configuration. The following overview contains every documented standard combination without the input suffix.
| Power | Voltage | Standard models | corresponding current ranges |
|---|---|---|---|
| 100 kW | 1,000 V | BSL 100-1000-200, BSL 100-1000-300, BSL 100-1000-400 | 200 / 300 / 400 A |
| 100 kW | 1,500 V | BSL 100-1500-133, BSL 100-1500-200, BSL 100-1500-266 | 133 / 200 / 266 A |
| 100 kW | 2,000 V | BSL 100-2000-100, BSL 100-2000-150, BSL 100-2000-200 | 100 / 150 / 200 A |
| 150 kW | 1,000 V | BSL 150-1000-300, BSL 150-1000-450, BSL 150-1000-600 | 300 / 450 / 600 A |
| 150 kW | 1,500 V | BSL 150-1500-200, BSL 150-1500-300, BSL 150-1500-400 | 200 / 300 / 400 A |
| 150 kW | 2,000 V | BSL 150-2000-150, BSL 150-2000-225, BSL 150-2000-300 | 150 / 225 / 300 A |
| 200 kW | 1,000 V | BSL 200-1000-400, BSL 200-1000-600, BSL 200-1000-800 | 400 / 600 / 800 A |
| 200 kW | 1,500 V | BSL 200-1500-266, BSL 200-1500-400, BSL 200-1500-533 | 266 / 400 / 533 A |
| 200 kW | 2,000 V | BSL 200-2000-200, BSL 200-2000-300, BSL 200-2000-400 | 200 / 300 / 400 A |
| 250 kW | 1,000 V | BSL 250-1000-500, BSL 250-1000-750, BSL 250-1000-1000 | 500 / 750 / 1,000 A |
| 250 kW | 1,500 V | BSL 250-1500-333, BSL 250-1500-500, BSL 250-1500-666 | 333 / 500 / 666 A |
| 250 kW | 2,000 V | BSL 250-2000-250, BSL 250-2000-375, BSL 250-2000-500 | 250 / 375 / 500 A |
| 300 kW | 1,000 V | BSL 300-1000-600, BSL 300-1000-900, BSL 300-1000-1200 | 600 / 900 / 1,200 A |
| 300 kW | 1,500 V | BSL 300-1500-400, BSL 300-1500-600, BSL 300-1500-800 | 400 / 600 / 800 A |
| 300 kW | 2,000 V | BSL 300-2000-300, BSL 300-2000-450, BSL 300-2000-600 | 300 / 450 / 600 A |
Dynamics and regulation
| Characteristic | Value | Meaning |
|---|---|---|
| Current rise time | < 5 ms | Fast transition to the programmed current. |
| Current transition, -90 to +90% | < 10 ms | Short changeover between sink and source direction. |
| Regulation time for 0 to 100% load change | < 5 ms | Response to a complete load transition. |
| Load regulation | 0.1% FS | Voltage deviation between no-load and load conditions relative to full scale. |
| Line regulation | 0.1% FS | Stabilisation under changes in the grid supply. |
| Voltage ripple / stability | 0.2% FS / 0.2% FS | Documented output characteristics. |
| Output accuracy, voltage / power | 0.1% FS / 0.3% FS | Separate accuracy figures for voltage and power. |
| Resolution, voltage / current / power | 0.1 V / 0.1 A / 0.1 kW | Increment of the adjustable or displayed quantities. |
Operating modes and programmable functions
| Function | Operation | Typical benefit |
|---|---|---|
| CV / CC / CP / CR | Regulates constant voltage, constant current, constant power or constant resistance. | Defined source and load conditions for different DUTs. |
| Sequence operation | Programs operating points, dwell times, transition times and cycles; save and import as CSV. | Repeatable profiles and endurance tests. |
| Battery simulation | Configures battery type, series/parallel arrangement, internal resistance, initial capacity and SOC; custom curves can be imported. | Emulation of charge and discharge behaviour without a real battery. |
| Battery test | Combines charge, discharge and rest steps with time and termination conditions. | Cycle, capacity, charge and discharge testing of batteries and packs. |
| PV simulation | Generates I-V curves from temperature, irradiance, Uoc, Isc, Ump and Pmax; supports static and dynamic MPPT tests. | Reproducible testing of PV inverters in accordance with EN 50530:2010. |
| Regenerative DC load | Loads the DUT in CC, CR, CV or CP operation and returns energy to the grid. | Efficient testing of energy sources and power electronics. |
Typical applications
Battery-pack and e-mobility testing
Charge, discharge, rest and cycle profiles test capacity, charge/discharge behaviour and lifetime of batteries or packs.
Battery simulation
The bidirectional source electrically emulates different battery types, SOC, internal resistance, and series and parallel arrangements.
PV inverter and MPPT testing
Programmable I-V curves and static and dynamic MPPT sequences represent different irradiance and temperature conditions.
Regenerative load testing
Power supplies, fuel cells, charging equipment, inverters and other power electronics can be tested with regenerative load operation.
Automated development and production testing
LAN, RS485, Modbus, sequences and measurement acquisition support reproducible workflows in development, quality assurance and production.
Interfaces, software and automation
| Equipment | Function |
|---|---|
| 12-inch TFT touch panel | Windows-based GUI for parameters, measurements, sequences, waveforms, status and fault display. |
| LAN | Remote control through a network; documented standard port 502. |
| RS485 | Remote control through a two-wire connection with signal ground; supports multi-drop links. |
| Modbus | Documented communication protocol for integration into automated test systems. |
| Programming commands | Control operating mode, output, limits and sequences, and query measurements, status and fault codes. |
| Waveform recording | Records output voltage and current, displays real-time and historical waveforms, and stores data for later analysis. |
| Remote sense | Measures voltage at the DUT and compensates for cable drop within the system's regulation capability. |
| Master-slave interface | Communication between parallel systems of the same power rating. |
Scaling and parallel operation
For higher total power, up to four BSL systems of the same power rating can be operated in parallel. Master-slave communication uses the designated fibre-optic and network connections; AC inputs and DC outputs are connected in parallel as specified for the installation. Four 300 kW systems provide the documented upper limit of 1.2 MW.
Installation and infrastructure
| Topic | Documented configuration |
|---|---|
| Standard AC input | 3P+N+PE, 380 V L-L ±10%, 47 to 63 Hz. |
| Input configurations | Model variants /380, /400 and /480 for 380, 400 or 480 V L-L ±10%; 3P+N+PE or 3P+PE. Other inputs on request. |
| Grid characteristics | Efficiency ≥ 90%, power factor 0.95 and THDi ≤ 3%. |
| Cooling and protection rating | Forced-air cooling and IP21. |
| Operating environment | 0 to 40°C, 20 to 90% relative humidity, non-condensing; indoor installation. |
| Clearance | Provide more than 600 mm clearance from walls or other equipment for ventilation. |
| Cabinet dimensions | Depending on the model, from 800 × 900 × 1,900 mm to 2,800 × 1,000 × 2,100 mm (W × D × H). |
| Weight | Depending on the standard model, approximately 1,150 to 2,800 kg; wheel base below 1,400 kg, channel-steel base from 1,400 kg. |
Protection and monitoring functions
Overvoltage
An adjustable overvoltage threshold switches off the power output when it is exceeded.
Overcurrent
Separate overcurrent protection supplements programmable current limits for source and regenerative directions.
Overpower
Power is monitored through an adjustable protection threshold and separate positive and regenerative limits.
Overtemperature
Temperature monitoring includes IGBT readings and initiates shutdown when a corresponding fault occurs.
Emergency-stop interface
A local emergency stop and an activatable external 24 V interface support integration into the system concept.
Status monitoring
Front indicators and the GUI report operating state, output status, subsystem faults and main-circuit faults.
BSL series FAQ
Can the BSL series deliver and absorb energy?
Yes. It operates as a programmable DC source or regenerative electronic load and returns absorbed energy to the grid.
Are maximum voltage and maximum current available simultaneously?
Only when the operating point is within the rated power and permitted wide-range characteristic. Voltage, current and power must be checked together.
How can total power be increased?
Up to four systems of the same power rating can operate in parallel in master-slave mode. The maximum documented total power is 1.2 MW.
Which regulation modes are available?
CV, CC, CP and CR regulate constant voltage, constant current, constant power or constant resistance.
How is the BSL series automated?
LAN, RS485, Modbus and programming commands provide remote control, limit setting, sequences, and measurement and status queries.
What is remote sense used for?
The feedback line measures voltage at the DUT so that the system can compensate for voltage drop along the connection cable.
Can the BSL series test battery packs?
Yes. Charge, discharge and rest steps with time or termination conditions support cycle, capacity, charge and discharge testing.
Can it simulate a battery?
Yes. Battery type, series/parallel arrangement, internal resistance, capacity and SOC are configurable, and custom simulation curves can be imported.
Is the BSL series suitable for PV inverter testing?
Yes. It generates PV I-V curves and supports static and dynamic MPPT tests in accordance with EN 50530:2010.
Technical consultation and project enquiry
Selecting a BSL configuration requires the target voltage range, source and sink current, continuous power, dynamic test sequence, AC grid connection, interfaces, and requirements for parallel operation and system integration.
Send us your project data for technical sizing of the appropriate BSL configuration.