Skip to main content Skip to search Skip to main navigation
PV & Grid Simulation

PV simulation and grid simulation for inverters, MPPT and grid tests

Realistic PV string profiles, dynamic I-V curves, MPPT scenarios, grid events, regenerative operation and AC load conditions for PV inverters, hybrid inverters and grid-connected energy systems.

I-V Curve Electronically reproduce PV strings and solar modules
MPPT Test tracking speed and stability
Grid Simulate voltage, frequency and grid faults
4Q Regeneration and bidirectional energy flows
Hybrid Test the PV, battery and grid sides together
Example test setup

PV inverter test with PV simulation, grid simulation and an AC load

Reproducible
DC side PV simulator I-V curve, irradiance, temperature, shading and MPPT profiles
DUT PV / hybrid inverter MPPT, efficiency, protection functions and feed-in behaviour
AC side Grid simulator / load Grid profiles, faults, regeneration and AC load simulation
ET System N38300 wide-range DC power supply for PV simulation ET System ZGX bidirectional AC/DC source and regenerative load ET System N75500 regenerative AC/DC grid simulator
Test solutions for PV, inverters and grid-connected energy systems

Reproduce realistic solar, load and grid conditions in the lab

PV inverters, hybrid inverters and energy systems must be tested under changing irradiance, temperature, string and grid conditions. For reproducible tests, ET System combines PV simulation software, DC sources, AC grid simulators, bidirectional AC systems and electronic loads.

Simulate PV strings under controlled conditions

PV simulation electronically reproduces the characteristic curve of a solar module or PV string. The inverter sees a realistic I-V curve and can be tested with changing irradiance, temperature, partial shading or defined test sequences.

Test grid conditions and regeneration

On the AC side, voltage, frequency, phase angle, voltage dips, over- and underfrequency, grid faults and regeneration scenarios can be simulated. Bidirectional systems such as ZGX or N75500 enable realistic energy flows and regenerative test setups.

PV PV array simulation I-V curves, PV parameters, curve sequences, weather and shading profiles for inverter tests.
MPPT MPPT validation Reproducibly test tracking speed, stability, dynamic curves and partial shading.
AC Grid tests Reproduce voltage, frequency, grid faults, phase angle, voltage dips and feed-in behaviour.
4Q Regenerative tests Bidirectional source/sink systems for regeneration, converter and hybrid inverter tests.
Typical test tasks

PV simulation, MPPT tests, grid compliance and hybrid inverter testing

The following tasks reflect typical requirements in development, validation, service, laboratory testing and the system integration of PV and grid components.

PV

Simulate a PV characteristic curve

A DC source and PV simulation software reproduce the I-V curve of a module or string. The inverter can be tested reproducibly under constant and dynamic PV conditions.

MPP

MPPT testing

MPPT testing checks how quickly and reliably the inverter finds the optimum operating point. Dynamic curves, irradiance changes and partial shading reveal the control behaviour of the DUT.

SHA

Weather and shading profiles

Shading, passing clouds, temperature changes and string mismatch are simulated as defined profiles. This makes it possible to reproduce real field conditions in the lab without weather-dependent test times.

GRID

Grid simulation and grid compliance

AC sources and grid simulators generate voltage, frequency, phase angle, over- and underfrequency, voltage dips, grid disturbances and regeneration scenarios for grid-connected inverters.

HYB

Test hybrid inverters

The PV side, battery connection and grid side are considered together. A DC source, bidirectional DC system, AC grid simulator and loads reproduce charging, discharging, backup and feed-in scenarios.

SERV

PV service and fault diagnosis

pvServe can simulate PV strings independently of sunlight. This supports service, maintenance, commissioning and fault diagnosis on modules, strings and inverters.

AC

AC load simulation

Electronic AC/DC loads reproduce real consumers, load steps and operating modes. This enables inverters, UPS functions, island grids and backup scenarios to be tested under defined conditions.

EOL

Automated test systems

Repeatable test sequences, interfaces, measurement data, limit values and reports can be integrated into customised test systems, from development benches to production testing.

µGRID

Microgrid and energy system tests

PV, batteries, inverters, loads and the grid can be considered in a combined test setup to validate control strategies, energy flows and protection functions.

ET System NS91000 photovoltaic simulation software
PV array simulation and MPPT

NS91000 with DC sources for I-V curves, PV parameters and dynamic MPPT tests

NS91000 PV simulation software can reproduce PV characteristic curves and test sequences. In combination with suitable DC sources, it supports static and dynamic PV scenarios, user-defined curves, curve sequences, and weather and shading profiles for inverter tests.

I-V Electronically reproduce module and string characteristic curves
MPPT Test tracking behaviour at dynamic operating points
Profiles Simulate weather, shading, curve sequences and test procedures
PV service and commissioning

pvServe for string simulation, inverter service and on-site fault diagnosis

pvServe supports PV service, maintenance, commissioning and fault diagnosis when a real solar generator is unavailable or defined test conditions are required. Inverters, strings and sections of a system can therefore be tested independently of sunlight.

0–1000 V Adjustable DC voltage for string simulation
Service Testing, maintenance and fault diagnosis for PV systems
Outdoor Work independently of actual sunlight
ET System pvServe multifunctional service tool for photovoltaics
ET System ZGX bidirectional AC/DC source with regenerative load
Grid simulation and regeneration

ZGX and N75500 for AC grid simulation, four-quadrant operation and regenerative tests

Defined grid profiles are essential on the AC side of an inverter. Bidirectional AC systems and regenerative grid simulators reproduce voltage, frequency, phases, grid faults, regeneration and dynamic load conditions — making them suitable for grid tests, hybrid inverters and grid-connected energy systems.

4Q AC/DC Source/sink operation and bidirectional energy flows
Grid Simulate grid events, frequency and voltage profiles
Regenerative Improve test-bench efficiency through energy regeneration
Suitable ET System solutions

Products for PV simulation, grid simulation and inverter testing

A selection of relevant product series for PV array simulation, MPPT testing, PV service, the DC side, AC grid simulation, regeneration, AC load simulation and complete test environments.

NS91000 photovoltaic simulation software
PV Simulation

NS91000

Photovoltaic simulation software for I-V curves, PV parameters, MPPT tests, curve sequences, and weather and shading profiles.

Static/Dynamic EN50530 Shadow Tests
pvServe multifunctional service tool for photovoltaics
PV Service

pvServe

Service power supply for string simulation, commissioning, maintenance and fault diagnosis on PV modules, strings and inverters.

0–1000 V DC Service Diagnosis
N38300 wide-range DC power supply
High-Power DC

N38300

Wide-range DC power supply for PV array simulation, DC links, and inverter and power module tests.

up to 180 kW up to 2250 V PV / DC
N36200 wide-range DC power supply
DC Source

N36200

Compact programmable DC source for PV-related tests, DC supply, laboratory use, development and ATE applications.

up to 10 kW up to 1500 V Autoranging
ZGX bidirectional AC/DC source and regenerative load
Bidirectional AC/DC

ZGX

Four-quadrant AC/DC source/sink system for grid tests, regeneration, inverters, UPS systems and PHIL test benches.

18 kVA / 4U 450 V L-N Regenerative
N75500 regenerative AC/DC grid simulator
AC/DC Grid Simulator

N75500

Regenerative grid simulator for AC, DC, AC+DC and DC+AC test scenarios involving inverters and energy systems.

25 kVA in 3U 1–500 Hz AC/DC
EAC-3S three-phase AC source
Three-Phase AC Source

EAC-3S

Three-phase AC power supply for grid profiles, frequency tests, inverter development and robust AC test benches.

Three-phase Variable frequency Grid tests
ASR-3400 AC source for grid simulation and inverter testing
AC Source / Grid Test

ASR-3400

Programmable AC source for grid profiles, frequency tests, inverter development and PV grid test setups.

AC Source Variable frequency Grid tests
AEL-5000 electronic AC/DC load
AC/DC Load

AEL-5000

Programmable electronic AC/DC load for inverters, UPS systems, island grids, backup scenarios and load profiles.

AC/DC up to 22.5 kW DC–440 Hz
N35500 bidirectional DC source with regenerative load
Bidirectional DC

N35500

Bidirectional DC source/sink system for battery connections, hybrid inverters, DC-side testing and regenerative DC tests.

42 kW in 3U up to 2250 V Regeneration
Selection guide

Which solution fits which test task?

This table provides initial guidance. The final configuration depends on DC voltage, power, the number of phases, grid profiles, dynamics, regeneration requirements, interfaces and the required standard tests.

Test task Recommended solution Benefit
Simulate a PV characteristic curve DC source + NS91000 Reproducible I-V curves, PV parameters and dynamic PV profiles for inverter and MPPT tests.
MPPT testing NS91000 + N38300 / N36200 Test tracking speed, stability, irradiance changes, temperature changes and partial shading.
On-site PV service pvServe String simulation independent of sunlight, plus fault diagnosis on modules, strings and inverters.
Test the AC side of an inverter ZGX / N75500 / EAC-3S / ASR Reproduce voltage, frequency, phase angle, grid events and AC input conditions under controlled conditions.
Grid compliance and grid faults N75500 / ZGX / AC source Reproducibly test voltage dips, over- and underfrequency, frequency variation, phase faults and protection functions.
Test regenerative operation ZGX / N75500 / EAC-4Q Test bidirectional energy flows, feed-in behaviour, regenerative load cases and dynamic grid conditions.
Test hybrid inverters DC source, N35500, ZGX/N75500, AC/DC load Reproduce the PV, battery and grid sides together: charging, discharging, backup, island-grid and grid-connected operation.
AC load profiles and backup scenarios AEL-5000 / AC load Simulate real consumers, load steps, UPS and island-grid behaviour, and load responses under controlled conditions.
Customised test system System integration A complete solution with sources, loads, regeneration, safety, software, interfaces, automation and documentation.
Project workflow

From the PV test task to a complete test environment

A clearly defined test setup reduces integration effort, increases reproducibility and enables automated testing for development, validation, service and production.

1. Define the DUT PV inverter, hybrid inverter, DC/DC stage, storage system, UPS or complete energy system.
2. Specify the DC side PV voltage, current, power, number of strings, I-V curves, MPPT dynamics and shading profiles.
3. Select the AC grid profile Number of phases, voltage, frequency, grid faults, regeneration, island-grid and grid-compliance scenarios.
4. Combine source & load DC source, PV software, AC grid simulator, bidirectional system, AC/DC load and measurement.
5. Automate Define test sequences, interfaces, safety functions, measurement data, limits and reporting.
Call to action

Get support with your PV or inverter test setup

Send us your PV or inverter test requirements, including DC voltage, current, power, number of phases, grid profiles, MPPT requirements, regeneration needs, interfaces and the standards you want to test against. ET System can help select a PV simulator, grid simulator and complete test environment.

PV voltage, current, power and number of strings
I-V curves, MPPT dynamics, weather and shading profiles
AC grid: phases, voltage, frequency and grid faults
Regeneration, island-grid, backup and hybrid operation
Interfaces: LAN, CAN, RS232, RS485, analogue, SCPI
Safety: EPO, interlock, isolation and protection concept