AEL-5002-350-18.75

Description
AEL-5002-350-18.75 AC/DC electronic load, 1.875 kW, AC 50–350 Vrms / DC 500 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 3.75 kW / 37.5 Arms
Current [A]
18,75
Power [P]
1875
Voltage [V]
350
AEL-5002-350-18.75
AEL-5002-350-18.75 AC/DC electronic load, 1.875 kW, AC 50–350 Vrms / DC 500 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 3.75 kW / 37.5 Arms
18,75
1875
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5003-350-28

Description
AEL-5003-350-28 AC/DC electronic load, 2.8 kW, AC 50–350 Vrms / DC 500 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 5.6 kW / 56 Arms
Current [A]
28
Power [P]
2800
Voltage [V]
350
AEL-5003-350-28
AEL-5003-350-28 AC/DC electronic load, 2.8 kW, AC 50–350 Vrms / DC 500 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 5.6 kW / 56 Arms
28
2800
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5004-350-37.5

Description
AEL-5004-350-37.5 AC/DC electronic load, 3.75 kW, AC 50–350 Vrms / DC 500 Vdc, 37.5 Arms / 112.5 Apeak, Turbo mode up to 7.5 kW / 75 Arms
Current [A]
37.5
Power [P]
3750
Voltage [V]
350
AEL-5004-350-37.5
AEL-5004-350-37.5 AC/DC electronic load, 3.75 kW, AC 50–350 Vrms / DC 500 Vdc, 37.5 Arms / 112.5 Apeak, Turbo mode up to 7.5 kW / 75 Arms
37.5
3750
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5002-425-18.75

Description
AEL-5002-425-18.75 AC/DC electronic load, 1.875 kW, AC 50-425 Vrms / DC 600 VDC, 18.75 Arms / 56.25 Apeak, turbo mode up to 3.75 kW / 37.5 Arms
Current [A]
18,75
Power [P]
1875
Voltage [V]
425
AEL-5002-425-18.75
AEL-5002-425-18.75 AC/DC electronic load, 1.875 kW, AC 50-425 Vrms / DC 600 VDC, 18.75 Arms / 56.25 Apeak, turbo mode up to 3.75 kW / 37.5 Arms
18,75
1875
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5003-425-28

Description
AEL-5003-425-28 AC/DC electronic load, 2.8 kW, AC 50–425 Vrms / DC 600 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 5.6 kW / 56 Arms
Current [A]
28
Power [P]
2800
Voltage [V]
425
AEL-5003-425-28
AEL-5003-425-28 AC/DC electronic load, 2.8 kW, AC 50–425 Vrms / DC 600 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 5.6 kW / 56 Arms
28
2800
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5004-425-37.5

Description
AEL-5004-425-37.5 AC/DC electronic load, 3.75 kW, AC 50–425 Vrms / DC 600 Vdc, 37.5 Arms / 112.5 Apeak, Turbo mode up to 7.5 kW / 75 Arms
Current [A]
37.5
Power [P]
3750
Voltage [V]
425
AEL-5004-425-37.5
AEL-5004-425-37.5 AC/DC electronic load, 3.75 kW, AC 50–425 Vrms / DC 600 Vdc, 37.5 Arms / 112.5 Apeak, Turbo mode up to 7.5 kW / 75 Arms
37.5
3750
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5006-350-56

Description
AEL-5006-350-56 AC/DC electronic load, 5.6 kW, AC 50-350 Vrms / DC 500 VDC, 56 Arms / 168 Apeak, turbo mode up to 11.2 kW / 112 Arms
Current [A]
56
Power [P]
5600
Voltage [V]
350
AEL-5006-350-56
AEL-5006-350-56 AC/DC electronic load, 5.6 kW, AC 50-350 Vrms / DC 500 VDC, 56 Arms / 168 Apeak, turbo mode up to 11.2 kW / 112 Arms
56
5600
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5008-350-75

Description
AEL-5008-350-75 AC/DC electronic load, 7.5 kW, AC 50–350 Vrms / DC 500 Vdc, 75 Arms / 225 Apeak, Turbo mode up to 15 kW / 150 Arms
Current [A]
75
Power [P]
7500
Voltage [V]
350
AEL-5008-350-75
AEL-5008-350-75 AC/DC electronic load, 7.5 kW, AC 50–350 Vrms / DC 500 Vdc, 75 Arms / 225 Apeak, Turbo mode up to 15 kW / 150 Arms
75
7500
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5012-350-112.5

Description
AEL-5012-350-112.5 AC/DC electronic load, 11.25 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 22.5 kW / 225 Arms
Current [A]
112.5
Power [P]
11250
Voltage [V]
350
AEL-5012-350-112.5
AEL-5012-350-112.5 AC/DC electronic load, 11.25 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 22.5 kW / 225 Arms
112.5
11250
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5015-350-112.5

Description
AEL-5015-350-112.5 AC/DC electronic load, 15 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 30 kW / 225 Arms
Current [A]
112.5
Power [P]
15000
Voltage [V]
350
AEL-5015-350-112.5
AEL-5015-350-112.5 AC/DC electronic load, 15 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 30 kW / 225 Arms
112.5
15000
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5019-350-112.5

Description
AEL-5019-350-112.5 AC/DC electronic load, 18.75 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 37.5 kW / 225 Arms
Current [A]
112.5
Power [P]
18750
Voltage [V]
350
AEL-5019-350-112.5
AEL-5019-350-112.5 AC/DC electronic load, 18.75 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 37.5 kW / 225 Arms
112.5
18750
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5023-350-112.5

Description
AEL-5023-350-112.5 AC/DC electronic load, 22.5 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 45 kW / 225 Arms
Current [A]
112.5
Power [P]
22500
Voltage [V]
350
AEL-5023-350-112.5
AEL-5023-350-112.5 AC/DC electronic load, 22.5 kW, AC 50–350 Vrms / DC 500 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 45 kW / 225 Arms
112.5
22500
350
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5006-425-56

Description
AEL-5006-350-56 AC/DC electronic load, 5.6 kW, AC 50–350 Vrms / DC 500 Vdc, 56 Arms / 168 Apeak, Turbo mode up to 11.2 kW / 112 Arms
Current [A]
56
Power [P]
5600
Voltage [V]
425
AEL-5006-425-56
AEL-5006-350-56 AC/DC electronic load, 5.6 kW, AC 50–350 Vrms / DC 500 Vdc, 56 Arms / 168 Apeak, Turbo mode up to 11.2 kW / 112 Arms
56
5600
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5008-425-75

Description
AEL-5008-425-75 AC/DC electronic load, 7.5 kW, AC 50–425 Vrms / DC 600 Vdc, 75 Arms / 225 Apeak, Turbo mode up to 15 kW / 150 Arms
Current [A]
75
Power [P]
7500
Voltage [V]
425
AEL-5008-425-75
AEL-5008-425-75 AC/DC electronic load, 7.5 kW, AC 50–425 Vrms / DC 600 Vdc, 75 Arms / 225 Apeak, Turbo mode up to 15 kW / 150 Arms
75
7500
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5012-425-112.5

Description
AEL-5012-425-112.5 AC/DC electronic load, 11.25 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 22.5 kW / 225 Arms
Current [A]
112.5
Power [P]
11250
Voltage [V]
425
AEL-5012-425-112.5
AEL-5012-425-112.5 AC/DC electronic load, 11.25 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 22.5 kW / 225 Arms
112.5
11250
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5015-425-112.5

Description
AEL-5015-425-112.5 AC/DC electronic load, 15 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 30 kW / 225 Arms
Current [A]
112.5
Power [P]
15000
Voltage [V]
425
AEL-5015-425-112.5
AEL-5015-425-112.5 AC/DC electronic load, 15 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 30 kW / 225 Arms
112.5
15000
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5019-425-112.5

Description
AEL-5019-425-112.5 AC/DC electronic load, 18.75 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 37.5 kW / 225 Arms
Current [A]
112.5
Power [P]
18750
Voltage [V]
425
AEL-5019-425-112.5
AEL-5019-425-112.5 AC/DC electronic load, 18.75 kW, AC 50–425 Vrms / DC 600 Vdc, 112.5 Arms / 337.5 Apeak, Turbo mode up to 37.5 kW / 225 Arms
112.5
18750
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5023-425-112.5

Description
AEL-5002-425-18.75 AC/DC electronic load, 1.875 kW, AC 50–425 Vrms / DC 600 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 3.75 kW / 37.5 Arms
Current [A]
112.5
Power [P]
22500
Voltage [V]
425
AEL-5023-425-112.5
AEL-5002-425-18.75 AC/DC electronic load, 1.875 kW, AC 50–425 Vrms / DC 600 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 3.75 kW / 37.5 Arms
112.5
22500
425
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5003-480-18.75

Description
AEL-5003-480-18.75 AC/DC electronic load, 2.8 kW, AC 50–480 Vrms / DC 700 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 5.6 kW / 37.5 Arms
Current [A]
18,75
Power [P]
2800
Voltage [V]
480
AEL-5003-480-18.75
AEL-5003-480-18.75 AC/DC electronic load, 2.8 kW, AC 50–480 Vrms / DC 700 Vdc, 18.75 Arms / 56.25 Apeak, Turbo mode up to 5.6 kW / 37.5 Arms
18,75
2800
480
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5004-480-28

Description
AEL-5004-480-28 AC/DC electronic load, 3.75 kW, AC 50–480 Vrms / DC 700 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 7.5 kW / 56 Arms
Current [A]
28
Power [P]
3750
Voltage [V]
480
AEL-5004-480-28
AEL-5004-480-28 AC/DC electronic load, 3.75 kW, AC 50–480 Vrms / DC 700 Vdc, 28 Arms / 84 Apeak, Turbo mode up to 7.5 kW / 56 Arms
28
3750
480
AC/DC Load

Technical Data

Product category

AC Electronic Load

Type of AC Load

Conventional Load

AEL-5000 series overview

The AEL-5000 is a series of programmable AC/DC electronic loads for testing AC and DC sources. The model range covers rated power from 1,875 to 22,500 W, 18.75 to 112.5 Arms and up to 337.5 Apeak. Three voltage families cover 50 to 350, 425 or 480 Vrms and up to 500, 600 or 700 Vdc. In addition to CC, CR, CV and CP, the series supports linear CC and non-linear rectifier load operation for AC applications. Programmable current waveforms, load and unload angles, half-wave operation, crest factor and power factor reproduce typical loads for UPS systems, inverters and power supplies. A time-limited Turbo mode increases RMS current and power to twice the rating for protection-component and limit tests. Measurement, test, storage and sequence functions, plus optional GPIB, RS-232, USB or LAN interfaces, support automated test systems.

Key benefits

Twice the load for short tests

For fuse, short-circuit, OCP and OPP tests, Turbo doubles rated current and power within defined time limits.

One load for two signal types

AC and DC operation plus CC, linear CC, CR, CV, CP and rectifier load cover different sources and load characteristics.

Reproduce real current waveforms

Adjustable CF and PF, 0–359° load angles, half-wave loading and SCR/TRIAC current waveforms support non-linear load testing.

Measure electrical quantities directly

The 16-bit measurement circuit captures RMS, peak, maximum and minimum values plus power, frequency, CF, PF, THD and harmonics.

Built-in test routines

Predefined functions support UPS, battery, fuse, short-circuit, OCP, OPP and inrush-current testing, among other tasks.

Scale single- and three-phase tests

Identical units can operate in a master-slave system and combine into synchronised three-phase Δ or Y loads.

How the AC/DC electronic load operates

The AEL-5000 absorbs electrical power from the connected device under test. In constant-current operation, CC regulates the current to the programmed setpoint. Linear CC transfers the shape of the input voltage to the load current, making it suitable for step, square and PWM voltage sources. In CR mode, current rises in proportion to voltage, while CP keeps absorbed power constant. In CV mode, the load sinks enough current to reach the programmed input voltage.

For AC tests, non-linear rectifier load operation supplements these control modes. Crest factor and leading or lagging power factor shape the load current. Load and unload angles, positive or negative half-wave loading and 90° SCR/TRIAC waveforms enable defined asymmetric and phase-controlled loads. In AC and DC setups, voltage, RMS current, peak current and power must simultaneously remain within the selected model's operating envelope.

Models, power ratings and voltage families

Rated values apply to each individual unit with Turbo disabled. Within the permitted test duration, Turbo doubles RMS current and power; the specified peak current remains unchanged. Turbo operation is intended for the Fuse, Short, OCP and OPP test functions.

ModelVoltage rangeRated / Turbo powerRated / Turbo currentPeak current
AEL-5002-350-18.7550–350 Vrms / 500 Vdc1,875 / 3,750 W18.75 / 37.5 Arms56.25 Apeak
AEL-5003-350-2850–350 Vrms / 500 Vdc2,800 / 5,600 W28 / 56 Arms84 Apeak
AEL-5004-350-37.550–350 Vrms / 500 Vdc3,750 / 7,500 W37.5 / 75 Arms112.5 Apeak
AEL-5002-425-18.7550–425 Vrms / 600 Vdc1,875 / 3,750 W18.75 / 37.5 Arms56.25 Apeak
AEL-5003-425-2850–425 Vrms / 600 Vdc2,800 / 5,600 W28 / 56 Arms84 Apeak
AEL-5004-425-37.550–425 Vrms / 600 Vdc3,750 / 7,500 W37.5 / 75 Arms112.5 Apeak
AEL-5006-350-5650–350 Vrms / 500 Vdc5,600 / 11,200 W56 / 112 Arms168 Apeak
AEL-5008-350-7550–350 Vrms / 500 Vdc7,500 / 15,000 W75 / 150 Arms225 Apeak
AEL-5012-350-112.550–350 Vrms / 500 Vdc11,250 / 22,500 W112.5 / 225 Arms337.5 Apeak
AEL-5015-350-112.550–350 Vrms / 500 Vdc15,000 / 30,000 W112.5 / 225 Arms337.5 Apeak
AEL-5019-350-112.550–350 Vrms / 500 Vdc18,750 / 37,500 W112.5 / 225 Arms337.5 Apeak
AEL-5023-350-112.550–350 Vrms / 500 Vdc22,500 / 45,000 W112.5 / 225 Arms337.5 Apeak
AEL-5006-425-5650–425 Vrms / 600 Vdc5,600 / 11,200 W56 / 112 Arms168 Apeak
AEL-5008-425-7550–425 Vrms / 600 Vdc7,500 / 15,000 W75 / 150 Arms225 Apeak
AEL-5012-425-112.550–425 Vrms / 600 Vdc11,250 / 22,500 W112.5 / 225 Arms337.5 Apeak
AEL-5015-425-112.550–425 Vrms / 600 Vdc15,000 / 30,000 W112.5 / 225 Arms337.5 Apeak
AEL-5019-425-112.550–425 Vrms / 600 Vdc18,750 / 37,500 W112.5 / 225 Arms337.5 Apeak
AEL-5023-425-112.550–425 Vrms / 600 Vdc22,500 / 45,000 W112.5 / 225 Arms337.5 Apeak
AEL-5003-480-18.7550–480 Vrms / 700 Vdc2,800 / 5,600 W18.75 / 37.5 Arms56.25 Apeak
AEL-5004-480-2850–480 Vrms / 700 Vdc3,750 / 7,500 W28 / 56 Arms84 Apeak

Check the operating point: Voltage, RMS current, peak current and power limits apply simultaneously. Full rated voltage and full rated current are therefore available together only when their product does not exceed rated power.

Operating modes and programmable test functions

FunctionOperationTypical benefit
CCConstant load current independent of input voltageLoad and dynamic testing of voltage sources
Linear CCLoad current follows the AC input-voltage waveformTest sine, step, square and PWM voltage sources
CRCurrent rises in proportion to input voltageResistive loading and a softer start for power supplies
CVLoad current regulates input voltage to the setpointTest current sources, chargers and current-limit characteristics
CPAbsorbed power remains constant as voltage changesBattery discharge and constant-power loading
AC rectifier loadNon-linear CC or CC+CR loadingReproduce rectifier-type loads on UPS systems and PV inverters
Store / RecallStore and recall up to 150 instrument states in EEPROMMake recurring configurations available without re-entry
Auto SequenceUp to 9 files with up to 32 steps, times and repeats eachRun automated load profiles directly in the instrument

Frequency, current waveform and measurement

DC to 440 Hz

The 350 and 425 V families operate with DC and 40–440 Hz. The 480 V models are specified for DC and 40–70 Hz.

Crest and power factor

Crest factor is adjustable from 1.414 to 5.0; power factor from 0.1 to 1.0 leading or lagging.

Defined switching angles

Load on and load off are programmable over 0–359°; positive and negative half-wave loading can be selected separately.

Inrush and surge current

Programmable current steps reproduce capacitive inrush current and suddenly connected loads for transient testing.

Capture power-quality quantities

VTHD, ITHD, voltage and current harmonics supplement RMS, peak, maximum and minimum readings.

Measure switching times

Timing functions support UPS transfer-time measurements plus trip and blow times of current-protection components.

Typical applications

UPS systems and inverters

Efficiency, backup and transfer time, on-load start-up, non-linear loading and transient response can be investigated with built-in functions.

PV inverter testing

The load measures efficiency and reproduces resistive plus non-linear loads at the AC output using rectifier and CC+CR operation.

Fuses, circuit breakers and PTCs

Trip and non-trip routines test operation and non-operation using programmable current, time and repetition plus measured trip time.

AC and DC power supplies

CC, CR, CV and CP plus short-circuit, OCP and OPP tests support the characterisation of regulation and protection limits.

Batteries and battery packs

CC and CP discharge with an undervoltage limit or programmed time captures capacity, final voltage and accumulated discharge time.

Production and batch testing

Remote control, stored states, sequences and GO/NG limits support repeatable testing of power supplies and chargers.

Interfaces and automation

InterfaceAvailabilityFunction
GPIB and RS-232Optional combination card or separate cardsRemote control and measurement queries in test systems
USBOptional interface cardComputer connection and remote control
LANOptional interface cardNetwork-based remote control
Analogue programming inputOptional, 0–10 VExternal setpoint input up to full scale for the selected operating mode
V monitor / I monitorIsolated monitor signals scaled to full range, up to ±10 VpeakObserve voltage and current waveforms externally
Remote senseVsense inputCompensate for load-lead voltage drop at the DUT
SYNC and master-slaveTTL synchronisation and 15-pin system connectionSynchronise instruments and three-phase load branches

Parallel operation and three-phase systems

Parallel operation uses identical AEL-5000 models. One master controls up to seven slaves, and the master displays total current and power. Within one single-phase branch, up to eight units and up to 180 kW can be combined. Series connection is not supported.

For three-phase tests, one master synchronises the individual phases in a Δ or Y configuration. Parallel load branches enable documented complete systems up to 540 kW. Available power depends on the number and rated power of identical units on each phase. Test functions are restricted in Boost parallel mode; they are available in 3PH mode.

Installation and infrastructure

CharacteristicRequirement or configuration
Instrument supply100–240 Vac ±10%, 47–63 Hz, protective-earth connection required
Operating environmentIndoor use, 0–40 °C, 0–85% relative humidity, altitude below 2,000 m
CoolingFront-to-rear airflow; at least 15 cm rear clearance is recommended
AEL-5002 / 5003 / 5004177 × 440 × 552.6 mm; 21.5 to 33.5 kg depending on model
AEL-5006 / 5008457.8 × 480 × 593 mm; 58 and 70 kg respectively
AEL-5012635.7 × 480 × 593 mm; 105 kg
AEL-5015813.5 × 480 × 593 mm; 140 kg
AEL-5019 / 50231,283 × 600 × 600 mm; 260 and 295 kg respectively

Short, twisted load leads reduce inductive voltage spikes and possible control oscillation. With long leads or low voltage, remote sense supports voltage measurement directly at the DUT.

Protection functions

The AEL-5000 monitors input voltage, load current, power dissipation and heat-sink temperature. Following overvoltage, overcurrent, overpower or overtemperature, the load switches off and displays OVP, OCP, OPP or OTP respectively. Fixed OVP, OCP and OPP thresholds are approximately 105% of the relevant model rating; current and power limits can additionally be programmed.

Airflow and rear ventilation openings must remain unobstructed. These instrument protection functions protect the load itself and should be incorporated into the safety concept for the complete test setup.

AEL-5000 FAQ

How do I select the appropriate model?

Check AC or DC voltage, RMS and peak current, and power at the same operating point. Also consider frequency range, Turbo requirements and instrument size.

Is Turbo intended for continuous operation?

No. Turbo is a time-limited doubling of RMS current and power for Fuse, Short, OCP and OPP tests. Permitted duration depends on the test function.

Can different models be connected in parallel?

No. Master-slave parallel operation requires identical models. Up to one master and seven slaves can form a single-phase load branch.

Are GPIB, RS-232, USB and LAN standard?

These computer interfaces are implemented as optional cards. The required interface should therefore be specified when configuring the instrument.

When is remote sense useful?

Remote sense compensates for voltage drop across longer load leads and is particularly useful at low voltage and high current. Sense-lead polarity must be observed.

Can the AEL-5000 test UPS systems and inverters?

Yes. Built-in routines support efficiency, backup and transfer-time testing; load angles, half-wave loading, inrush current and non-linear loads extend the investigation.

Is the series suitable for PV inverter testing?

Yes. Efficiency can be measured at the AC output, while rectifier or CC+CR operation reproduces resistive plus non-linear loads.

Can fuses and circuit breakers be tested?

Yes. Trip and non-trip tests use adjustable current, time and repetition. Turbo temporarily extends available RMS current and power for these tests.

Technical consultation and project enquiry

To select an appropriate AEL-5000 configuration, provide the AC and DC voltage range, required RMS and peak current, continuous and short-term power, and the intended current waveforms and test functions. Include frequency, interface, number of phases, and requirements for parallel operation, wiring and cooling.

Discuss your AEL-5000 project with ET System

Get in touch with us

+49 (0) 6205 - 3948-0 info@et-system.de

Mon - Thu: 8:00 AM - 5:00 PM
Fri: 8:00 AM - 3:00 PM

Contact Us Directly

+49 (0) 6205 - 3948-0 info@et-system.de

Mo - Do von 8 - 17 Uhr
Fr von 8 - 15 Uhr

Contact Us Directly